《Bogen-CC4021-Operation-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bogen-CC4021-Operation-Manual 电路图 维修手册.pdf(12页珍藏版)》请在收音机爱好者资料库上搜索。
1、CC Ser ies Amplifier Model CC4021 Installation and Use Manual INPUINPUT 1T 1 0 100 10 PEAKPEAKSIGNASIGNAL LPOWEPOWER R POWEPOWER BASS R BASSTREBLTREBLE 0 -12 E 0 -12 +12-12 +12-12 +12 +12 0 0 INPUINPUT 2T 2 0 100 10 2012 Bogen Communications, Inc. All rights reserved. Specifications subject to chang
2、e without notice. 54-2214-01A 1211 RadioFans.CN 收音机爱 好者资料库 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN NOTICE: Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. However, information is subject to change. WARNING: To reduce the risk
3、 of Fire or Electric Shock, Do Not Expose this apparatus to rain or moisture. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases shall be placed on the apparatus. WARNING: Only connect unit to AC mains outlet providing protective earthing connec
4、tion. NOTE: Mains plug is used as disconnect device from the mains and shall remain readily accessible and operable. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in
5、the operating instructions unless you are qualified to do so. CAUTION: DO NOT INSTALL OR PLACE THIS UNIT IN A BOOKCASE, BUILT-IN CABINET, OR IN ANOTHER CONFINED SPACE. ENSURE THE UNIT IS WELL VENTILATED. TO PREVENT THE RISK OF SHOCK OR FIRE HAZARD DUE TO OVERHEATING, ENSURE THAT CURTAINS AND ANY OTH
6、ER MATERIALS DO NOT OBSTRUCT THE VENTILATION VENTS. Always follow these basic safety precautions when installing and using the unit: IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus ne
7、ar water. 6. Clean unit with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defea
8、t the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, are provided for your safety. If the provided plug does not fit into your
9、 outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12.
10、 Unplug this apparatus during lightning storms or when not used for long periods of time. 13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects hav
11、e fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE ANY FRONT/BACK COVERS OR PANELS. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. Th
12、e exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions. The lightning flash with arrowhead symbol, within an equi- lateral triangle, is intended to alert the user to the presence of uninsulated
13、dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. RadioFans.CN 收音机爱 好者资料库 3 Cont ent s Impor t ant Safet y Infor mat ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Panel Des c
14、r ipt ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15、. . . . . . . . . . . . . . . . . .5 Out put Connect ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Speaker Outputs REC Output Input Connect ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16、6 Balanced- LINE/MIC Input 1 Unbalanced Input Wiring AUX Input 2 24V DC IN Oper at ion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Level Controls Bass and Treble Controls LINE/MIC Selector Switch Mute Send Cooling . . . . . . . . .
17、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Acces s or ies : Rack Mount Adapt er . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Limit ed War r ant y; Exclus ion of Cer t ain Damages . . . . . . . . . . . . . . . . .
18、. . . . . . . .8 Technical Specificat ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 RadioFans.CN 收音机爱 好者资料库 INPUINPUT 1T 1 0 100 10 PEAKPEAKSIGNASIGNAL LPOWEPOWER R POWEPOWER BASS R BASSTREBLTREBLE 0 -12 E 0 -12 +12-12 +12-12 +12 +12 0 0 INPUINPUT 2T
19、 2 0 100 10 Panel Des cr ipt ions 4 1 432 1.Bas s Exclus ion of Cer t ain Damages 9 Out put Power . 40W RMS; Minimum 1 kHz rated distortion; Continuous operation at 1/3 of Full Rated Power (FRP) Fr equency Res pons e Balanced LINE/MIC. 100 Hz to 20 kHz; 0/-3 dB Unbalanced Input . 80 Hz to 20 kHz; 0/
20、-3 dB Dis t or t ion Balanced LINE/MIC. 1% THD+N; Maximum, Full rated bandwidth Unbalanced Input . -60 dBr Phant om Power . 12V DC min., 18V DC max. Max. Ambient Temper at ur e. 100 deg. F (non-condensing) Ther mal Emis s ions . 141.5 BTU/hr. (full power) Ext er nal Supply . 24V DC; 3A Dimens ions. 8-1/4” W x 3-1/2” H x 10-3/8” D Pr oduct Weight. 10 lb. Lis t ings . Listed to UL Standard 60065 for US and Canada Technical Specificat ions Not es 10 Not es 11 50 Spring Street, Ramsey, NJ 07446, USA Tel. 201-934-8500 Fax: 201-934-9832