《Bogen-CS1EZ-Operation-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bogen-CS1EZ-Operation-Manual 电路图 维修手册.pdf(2页珍藏版)》请在收音机爱好者资料库上搜索。
1、Easy Design TM Speaker Model CS1EZ Speaker Layout The layout of the speakers should be planned before installation begins. Layout starts in one corner of the room. The first speaker should be positioned from each wall a distance approximately equal to the ceiling height of the room. The next speaker
2、 in row 1 should be spaced a distance approxi- mately equal to twice the height of the ceiling. Each additional speaker in the row should use this same spacing. Row 2 starts at twice the ceiling height distance from row 1 and twice the ceiling height from the wall. The other speakers in this row are
3、 also spaced at twice the ceiling height. Row 3 is again spaced at twice the ceiling height from the previ- ous row. The first speaker starting this row is positioned at one ceiling height distance from the wall (similar to row 1). Continue this pattern of alternating rows until the room is covered.
4、 The spacing of the speakers can be adjusted so that the speakers are evenly spaced in a row and aesthetically pleasing. TB8 Tile Bridge - The TB8 supports the weight of the speaker and recessed enclosure. This is also the item to which the speaker mounting screws attach. The TB8 is required for eac
5、h speaker assembly installed. TB8 Tile Bridge RE84 Recessed Enclosure RE84 Recessed Enclosure - The RE84 is an optional back box for ceiling speakers. UL Listed for use where ceiling plenum is part of an air handling system. The RE84 also includes attachment tabs allowing the enclosure to be sup- po
6、rted from structures other than the actual ceiling grid. Additional Hardware 54-5043-01C 1209 1999 Bogen Communications Inc. All rights reserved. Specifications subject to change without notice. RadioFans.CN 收音机爱 好者资料库 50 Spring Street, Ramsey NJ 07446, USA Tel. 201-934-8500 Fax: 201-934-9832 Speake
7、r Installation STEP 1 - Remove the tile from ceiling and center the TB8 tile bridge on the back. Use the tile bridge to trace out, and then cut an 8-1/2” square hole. NOTE: I t i s somet i mes mor e ef f i ci ent t o st ack up a number of cei l i ng t i l es and t hen cut t he speaker openi ng i n a
8、 number of t hem at once. STEP 2 - If using the optional RE84 Recessed Enclosure, bend up the 4 horseshoe tabs (see figure 1 on the TB8). Position the TB8 over the hole in the tile and push down the locator tabs (see figure 2). STEP 3 - Using the 4 supplied screws, attach the CS1EZ to the TB8 using
9、the 4 clips in the corners of the opening on the TB8 as nuts. NOTE: Onl y t i ght en t he scr ews unt i l t he gr i l l e i s snug agai nst t he t i l e. Over t i ght eni ng wi l l cause t he scr ews t o di mpl e t he gr i l l e. STEP 4a - If not using RE84 Recessed Enclosure: Make the electrical co
10、nnections using the 2 screw terminals on the CS1EZ. The suggested amplifier connections are: 70V terminal - 70V HOT COM terminal - 70V COMMON NOTE: The speaker wi l l al so wor k per f ect l y wel l wi t h t hese connect i ons r ever sed. However , i t i s i mpor t ant t o be consi st ent i n t he w
11、i r i ng of t he speaker s i n t he syst em. I f adj acent speaker s have r ever sed wi r i ng connect i ons, t hey wi l l t end t o cancel each ot her s bass r esponse, di mi ni shi ng t he sound qual i t y . STEP 4b - If using RE84 Recessed Enclosure: Install an entry fitting to a knock-out in the
12、 RE84 to accom- modate the plenum cable. Feed cable through RE84 entry and clamp. Make speaker connections as in 4a. All connec- tions and any splices must be made within the enclosure. Place the RE84 over the horseshoe tabs (see step 2) and twist the tabs with pliers to secure the RE84 to the TB8.
13、STEP 5 - Place the assembled ceiling tile back into the ceiling. Figure 1 Figure 2 The CS1EZis warranted to be free from defects in material or workmanship for three (3) years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installa
14、tion and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey , NJ 07446, USA. The product(s) will be returned to you freight prepaid. This warranty does not ext
15、end to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced. THE FOREGOING LIMITED WARRANTY
16、IS BOGENS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERS SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOW
17、ABLE BY LAW. Bogens liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty , contract, tort or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL
18、 DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the exclusion or limita- tion of inciden
19、tal or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. Products that are out of warranty will also be repaired by the Bogen Factory Service Department -
20、 same address as above or call 201-934-8500. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to parts and labor charges will be at the owners expense. All returns require a Return Authorization number. 7/22/2008 Li mi ted War r anty; Ex cl usi on of Cer tai n Damages RadioFans.CN 收音机爱 好者资料库