《Bogen-PCM200-Operation-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bogen-PCM200-Operation-Manual 电路图 维修手册.pdf(40页珍藏版)》请在收音机爱好者资料库上搜索。
1、 2012 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-5019-01C 1209 PCM2000 Configuration Guide RadioFans.CN 收音机爱 好者资料库 2 RadioFans.CN 收音机爱 好者资料库 Contents SECTION I - APPLICATIONCONFIGURATIONS .4-31 Configuration 1: Page Port Contact Closure/3-Zone
2、/One-Way Paging/Single Amplifier/25 and the contact closure pair to pins 2 page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex. Then return to this page to complete the following Steps. Set the SYS-ID DIP switches on the master
3、PCMCPU module to the OFF position (to the left). Set the SYS-ID DIP switches on the first satellite PCMCPU module to the following configuration: Switch 1 to the ON position (to the right). Switches 2, 3, page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground Start Trunk; or page
4、13 for Station Level/Centrex. Set the SYS-ID DIP switches on the PCMCPU to the OFF position (to the left). Set the RUN-PROGRAM switch on the PCMCPU to the RUN mode (up). Set the TALK BACK switches for the zones requiring two-way talk back to the ON position (right) on the PCMZPM module. Set the OUTP
5、UT switch on the PCMZPM module to the HI-PWR position (down). STEP 4: Testing your System Connect power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals observing polarity. At this point all the power LEDs should be lit on each module.
6、 Access the paging from the phone system and verify access tones (double beep) in handset. Speak into the handset and listen. You should be able to hear the Talk Back Relay clicking back and forth inside the PCMTBM module. (You must be near the PCM unit to hear it.) At this point, the system should
7、be functioning properly. Disconnect Power Supply. STEP 5: Connecting the Paging Amplifier Locate the terminals on the PCMTBM module labeled PA OUT/RT and wire to the COMMON and either 25 or 70V output on the Bogen paging amplifier (either TPU-Series, GS-Series or Classic Series). Locate the terminal
8、s on the PCMTBM module labeled PA IN/RT and wire to the TIP and RING input on the Bogen paging amplifier. STEP 6: Connecting 25 page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex. Then return to this page. Set the SYS-ID DIP sw
9、itches on the master PCMCPU module to the OFF position (to the left). Set the SYS-ID DIP switches on the first satellite PCMCPU module to the following configuration: switch 1 to the ON position (to the right), switches 2, 3, page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground
10、Start Trunk; or page 13 for Station Level/Centrex. Then return to this page to complete the following Steps. Set the SYS-IDswitches on the PCMCPU to the OFF position (to the left). Set the TALKBACK switches on the PCMZPM to the OFFposition (to the left) for all zones. Set the LO PWR / HI PWR OUTPUTs
11、witch on the PCMZPM to the LO PWRposition (up). STEP 4: Connecting Self-Amplified Speakers Connect the + - for Zone A to the Audio Input on the Self-Amplified Speakers. Repeat this step for both Zone B and Zone C. STEP 5: Testing your System Connect the power supply PCMPS2 to the PCMCPU module to ei
12、ther the power jack 12V DC input or wire it to the 12V DC screw terminals, observing polarity. Access the paging from the telephone system and listen (on the handset) for the confirmation tone (double beep). Dial 01 to access ZONE ONE and listen (on the handset and also to the speakers) for a pre-an
13、nounce tone (single beep) followed by your page (audio). Follow the same steps for ZONES TWO (02) and THREE (03). Dial 00 for All-Page. 22 SETUPFORCONFIGURATION 10: 6 ZONES/ ONE-WAYPAGING / MIXEDHIGH- ANDLOW-POWERZONES / 25 page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground St
14、art Trunk; or page 13 for Station Level/Centrex. Then return to this page to complete the following Steps. Set the SYS ID switches on the PCMCPU module to the OFF position (to the left). Set the TALK BACK switches on the PCMZPM module to the OFF position (to the left) for all zones. Set the LO PWR /
15、 HI PWR OUTPUT switch on the first PCMZPM High-Power module to the HI PWR OUTPUT position (down). Set the LO PWR / HI PWR OUTPUT switch on the second PCMZPM Low-Power module to the LO PWR OUTPUT position (up). STEP 4: Connecting Amplifiers Locate the terminals on the PCMCPU module labeled PA IN/RT a
16、nd wire it to the TIP and RING (T page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex. Then return to this page to complete the following Steps. Set the Line/MIC switch on the VAR1 to the MIC position. Set the Mic volume control
17、 on the VAR1 at 50%. STEP 5: Testing Your System Connect the power supply PCMPS2 to the PCMCPU module to either the power jack 12V DC input or wire it to the 12V DC screw terminals observing polarity. Connect the Bogen amplifier to the AC power outlet (120V AC 60Hz). Set the volume on your Bogen amp
18、lifier a half turn. Access the paging from the telephone system and listen (on the handset) for the confirmation tone (double beep). Dial 01 to access ZONE ONE and listen (on the handset and also to the speakers) for a pre-announce tone (single beep) followed by your page (audio). Follow the same st
19、eps for ZONES TWO (02) and THREE (03). Access the emergency override by pressing the talk bar on the MBS1000A or sliding the DDU250 switch. You should hear a quad beep pre-announce tone followed by your all-call/emergency page. Adjust the VAR1 and PCM2000 controls for optimal operation. NOTE: You wi
20、ll not be able to access individual zones using the Override feature, it is for All-Call Emergency only to all zones. 26 G BK R Y BLW Not used Play status contact common Audio output (-) Audio output (+) Play status contact Not used 6 CONDUCTOR MODULAR CABLE RJ 11 MODULAR BOX G BK R Y BLW PBX ANALOG
21、 LINE Note Switch settings: Off - Up, On - Down 24V DC POWER SUPPLY PCM TIM 11s 6 1s MAXMAX TIMETIME MINMIN TIMETIME 100100 1 0 1 VOX ENABLEVOX DIS CONF TNPRE ANN TN TRUNK MODESTATION LOOP STARTGND START DETECT CPCIGNORE 0 TONE TONE MUSIC MUSIC VOXVOX DELAYDELAY STATION/ TRUNK PAGE OUT ON PTPR G/SNO
22、CTR 24VDC 150mA CONTACT CLOSURES NC 1-RNG DLY NO TIMERTRNK TMER ANS IMMED RANGE (SEC) INHIBIT1 1 100 - 2000 1 50 - 10001 1 - 5000 PAGINGPAGING TIMETIME TAMB2TELEPHONE PAGING ACCESS MODULE O N 123456789 DFT120 SETUP FORCONFIGURATION12: DFT120 the TAMB2 module is connected to the Bogen Digital Feedbac
23、k Terminator model DFT120; and the DFT120 is connected to the PCM2000 system. The TAMB2 module is activated by the telephone system and, at the same time, the DFT120 is activated by the TAMB2s normally open contacts. Using digital technology, the DFT120 stores the DTMF tones and the paging audio. Wh
24、en the TAMB2 closed contacts are removed from the DFT120, the DFT120 activates the PCM2000 system also using normally open contacts, and plays the page (audio). In addition to the above equipment, you will also need a 24V DC power supply and two RJ11 modular boxes. INSTALLATION: STEP 1: Assemble Mod
25、ules PCMTIM to PCMCPU and to PCMZPM (see Illustration/Instructions on Appendix page 37, then returnto this page and complete the following Steps). Note: DO NOT connect the PCMPS2 (power supply) at this point. STEP 2: Connecting the Paging Amplifier Locate the terminals on the PCMCPU module labeled P
26、A IN/RT and wire to the TIP and Ring (T page 7 for Page Port VOX; page 9 for Loop Start Trunk; page 11 for Ground Start Trunk; or page 13 for Station Level/Centrex. Then return to this page to complete the following Step. STEP 5: Testing Your System Connect the power supply PCMPS2 to the PCMCPU modu
27、le to either the power jack 12V DC input or wire it to the 12V DC screw terminals, observing polarity. Connect the Bogen amplifier to the AC power outlet (120V AC 60Hz). Set the volume on your Bogen amplifier to a half turn. Press the normally open customer supplied switch once and listen for the em
28、ergency tones. 30 CONFIGURATION 14: SINGLE AMPLIFIER BACKGROUND MUSIC LINE-LEVEL SIGNAL Single amplifier BGM operation is a programmable feature that lets the PCM2000 use the paging amplifier to provide high-power BGM to the 25/70V AC speakers when the paging system is idle. INSTALLATION: STEP 1: Co
29、nnecting Telephone System Paging Output to the PCMTIM Refer to paging access modes described previously in STEP 2 on page 5 (Paging Port/Contact Closure); page 7 (Page Port/VOX); page 9 (Loop Start Trunk); page 11 (Ground Start Trunk); or page 13 (Station Level/Centrex). Then return to this page to
30、complete the following Steps. STEP 2: Connecting the BGM Source Connect the BGM source output to the PCMTIM module terminals labeled BGM SRC/RT. STEP 3: PCMCPU Switch Settings Remove the switch lock on the PCMCPU module and place the PROGRAM/RUN switch to the PROGRAM position (down), the green LED w
31、ill illuminate. Refer to Switch setting described previously in STEP 3 on page 5 (Paging Port/Contact Closure); page 7 (Page Port/VOX); page 9 (Loop Start Trunk); page 11 (Ground Start Trunk); or page 13 (Station Level/Centrex). Then return to this page to complete the following Steps. STEP 4: Activ
32、ating the Background Music Access the PCM2000 system (either use a single 2500-series line telephone or butt set or dial the paging access number from the telephone system). You will hear 3 beep tones indicating access to the programming mode. Dial 019 follow by the ( # ) key. You will hear a short
33、double beep if the programming was accepted and stored in the system. STEP5: Prepare System for Operation Hang up the programming phone and then place the PROGRAM/RUN switch in the RUN position. The green LED will go out. Replace the switch lock. BOGEN DIGITAL TUNER Music Source POWER PCM TIM 31 POW
34、ER RD COM + - RD A RD B ZONE A ZONE B ZONE C OFF ON TALKBACK RT IN RD C LOCAL BGM ZONE A + - ZONE B + - ZONE C LPBGM VOLUME LO PWR HI PWR OUTPUT BGM OUT IN - + SUPRESSION DIODES POWER SUPPLY 12VDC RELAY RELAY RELAY ZONE A ZONE B ZONE C GLOBL BGM CONFIGURATION 15: RELAYDRIVEROUTPUT Each PCMZPM module
35、 has three relay driver outputs - RD A, RD B, and RD C - one for each speaker zone. When a zone is activated, its relay driver is shorted to RD COM through an open collector transistor. These drivers can be used to activate external relays to provide greater power capacity or to operate external equ
36、ipment. The power supply for these relays must be 12V DC or less. The total sink current per driver can not exceed 100mA. SUPPRESSION DIODES 32 SECTION II - PROGRAMMING SYSTEMPROGRAMMING System programming lets you set certain PCM options and tone features using the DTMF keys of a telephone. It also
37、 lets you program paging zone groups and signaling zone groups. All programming is accomplished through the TRUNK/P/P jack on the PCMTIM module regardless of the telephone interface used. Note: To simplify initial programming, it is recommended that you use the Loop Start Trunk configuration with a
38、single-line 2500-series telephone or your Butt Set connected to the TRUNK/P/P input. You do not need to program the system to set the zones. The system is ready from the factory to access individual zones and All-Call. To program the PCM2000 system, follow these instructions: 1. Remove the switch lo
39、ck on the PCMCPU module and place the PROGRAM/RUN switch to the PROGRAM position (down). The green LED will illuminate. 2. Access the PCM2000 system (either use a single 2500-line telephone or butt set or dial the paging access number from the telephone system). 3. You will hear 3 beep tones indicat
40、ing access to the programming mode. 4. Dial the Feature Code for the option you wish to program. (See Feature Codes and Defaults list.) Note: After you have entered a Feature Code (and any other data), you must press the # key to enter it into the system. If the system accepts the code (and data), y
41、ou will hear a short double beep confirming that the data has been stored in the system. Continue with the next Feature Code immediately after the confirming double beep. If the information is not accepted, you will hear a busy tone. In this case, you should hang-up, check the code and the data, the
42、n re-ac- cess the system and try again. 5. Once you have finished programming, you must first hang-up the programming phone and then place the Program/Run switch in the Run position. The green LED will go out. Replace the switch lock. Remember to press the # key after you enter a Feature Code. 33 FE
43、ATURE CODES AND DEFAULTS Feature Feature Code Additional Data Default Privacy Beep Inhibit 006 Enable 007 Enable Pre-announce Tone Inhibit 003 Beep 004 Chime 005 Chime Confirmation Tone Inhibit 001 Enable Enable 002 Emergency O/R Tone Inhibit 008 Inhibit Enable 009 All-Call Inhibit 010 Enable 011 Enable Dialing Time-out Inhibit 012 Enable 013 Enable Trunk Disconnect Inhibit 014 Inhibit Enable 015 1 Amp BGM Inhibit 018 Inhibit Enable 019 Default Timer 050 00-99 03 (See Note 1 - p. 35) VOX Timer 051 0-9 6 (See Note 2 - p. 35) Zone Group *01 Zones Numbers No Zones *32 EM/SC Zone Group *92