Bogen-TNG1S-Operation-Manual 电路图 维修手册.pdf

上传人:cc518 文档编号:333215 上传时间:2026-07-03 格式:PDF 页数:3 大小:222.08KB
下载 相关 举报
Bogen-TNG1S-Operation-Manual 电路图 维修手册.pdf_第1页
第1页 / 共3页
Bogen-TNG1S-Operation-Manual 电路图 维修手册.pdf_第2页
第2页 / 共3页
Bogen-TNG1S-Operation-Manual 电路图 维修手册.pdf_第3页
第3页 / 共3页
亲,该文档总共3页,全部预览完了,如果喜欢就下载吧!
资源描述

《Bogen-TNG1S-Operation-Manual 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Bogen-TNG1S-Operation-Manual 电路图 维修手册.pdf(3页珍藏版)》请在收音机爱好者资料库上搜索。

1、TNG1S Tone Generator Module Features Select from burst/steady, slow whoop, siren, mechanical bell, Klaxon, night ringer, double chime, and doorbell tones Select 4 of 8 tones to trigger Momentary and continuous playback modes Screw terminal for 4 external trigger connections Level control Microproces

2、sor-controlled operation 4 levels of available priority Can be muted from higher priority modules Can mute lower priority modules Block Diagram 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500; Fax: 201-934-9832; Printed in Taiwan.0209 2002 Bogen Communications, Inc. 54-2080-01R2 Specifi

3、cations subject to change without notice. Tone-Trigger Terminal Strip External contact closures that are connected here trigger tone playback. Level Controls Controls output level of module tones. Front Panel Callouts GAINMUTING MUTE IN MUTE OUT BUS ASSIGNMENT PRIORITY LEVEL BUS A BUS B MUTE LOW MUT

4、E MED MUTE HIGH A B C D E F G H TONE SELECTION MICROPROCESSOR CONTROLLED TONE GENERATOR T1 T4 T3 T2 COM RadioFans.CN 收音机爱 好者资料库 Jumper Selections* Tone Selection The TNG1S provides a menu of 8 tones; of which 4 can be selected to be triggered from the terminal strip. Place up to 4 jumper shunts at t

5、he lettered position that corresponds to the desired tones (use Tone Selection Table above).The tones will be assigned to the trigger terminals in the order they fall into from A to H where the first tone selected on the way from A to H is assigned to T1, the next tone selected is assigned to T2, an

6、d so on. If more than 4 tones are selected,only the first 4 (from A to H) are assigned to the terminal strip.If less than 4 tones are selected, then only the terminals needed to correspond to the number of tones will be opera- tional. Priority Level* This module can respond to 4 different levels of

7、priority. Priority 1 is the highest priority. It mutes modules with lower priorities and is never muted. Priority 2 can be muted by Priority 1 modules and mutes modules set for 3 or 4. Priority 3 is muted by either Priority 1 or 2 mod- ules and mutes Priority 4 modules.Priority 4 modules are muted b

8、y all higher priority modules. If the TNG1S is muted by a higher priority while it is playing a tone,it will abort that tone play- back. If the trigger is still active when the TNG1S is unmuted, the tone will begin playing from the beginning. If the trigger is not active, the TNG1S will resume scann

9、ing the terminal triggers for activity. Bus Assignment Certain Bogen products that accept input modules contain two mix buses.In these products,the Bus Assignment jumpers can be arranged so that the tones are fed to either or both buses. On single bus products,both bus outputs are tied together.In t

10、his case assigning the output to either or both buses provides the same operation. Using the “Both” jumper arrangement is recom- mended for these systems. * Markings on circuit board may differ; use diagram above as reference for jumper settings. *The number of priority levels available is determine

11、d by the amplifier the modules are used in. Module Installation 1.Turn off all power to the unit. 2.Make all necessary jumper selections. 3.Position module in front of any desired module bay opening, making sure that the module is right-side up. 4.Slide module on to card guide rails. Make sure that

12、both the top and bottom guides are engaged. 5.Push the module in to the bay until the faceplate contacts the units chassis. 6.Use the two screws included to secure the module to the unit. WARNING: Turn off power to unit and make all jumper selections before installing module in unit. Connections Con

13、nect a contact closure between any of the “T” labeled terminals and the COM terminal to trigger a tone playback.An open collector type output can also trigger operation.A ground from the open collector triggering device must be connected to the COM terminal to com- plete the conduction path. Playbac

14、k modes One Time When a trigger is applied and removed before the tones playback cycle finishes, the tone will play only that one time and stop.A momentary trigger must be present for at least 10 ms to ensure that the TNG1S will recognize it and no other tone can be playing when the trigger pulse is

15、 applied since the module ignores other triggers applied during tone playback. Continuous To cause continuous play of a tone, the trigger must be applied for the entire time during which the tone is to play. Continuous play of a tone is actually a retriggering of the one time tone cycle again and ag

16、ain.At the end of a tones playback cycle, the TNG1S will recheck the status of this tones trigger. If it detects a trigger, it immediately retriggers the tone and causes it to play again.This process continues until the trigger is removed. Once the trigger is removed, the tone will finish its curren

17、t tone cycle and stop. Some of the tones contain short pauses between tone playbacks to make them sound proper when played as a continuous train. A very short break in playback will occur during continuous operation of the mechanical bell and 512 Hz steady tones. Trigger operation There is no priori

18、ty structure assigned to the different trigger inputs.Triggering is on a first- come, first-serve basis.The internal microprocessor constantly scans the 4 trigger inputs for activity and responds to the first trigger it detects as active. Once a tone is triggered, it takes control of the module oper

19、ation.All other triggers applied during the tone playback cycle will be ignored. Once a tone has stopped, the microprocessor continues scanning through the trig- ger inputs until it detects another trigger and begins playback of that tone. J6 ABCDEFGH A B CH J5 J7 J6 J5 J7 J6 J5 J7 J6 J5 J7 1 (Highe

20、st) 2 3 4 (Lowest) PRIORITY LEVEL BUS ASSIGNMENT A BBoth J8J8 Bus TONE SELECTION JUMPER FIELD J8 J6 J5 J7 J8 A512 Hz Steady BSlow Whoop CSiren DMechanical Bell EKlaxon FNight Ringer GDouble Chime HDoorbell Tone Selection Table RadioFans.CN 收音机爱 好者资料库 TNG1S Tone Generator Module Features Select from

21、burst/steady, slow whoop, siren, mechanical bell, Klaxon, night ringer, double chime, and doorbell tones Select 4 of 8 tones to trigger Momentary and continuous playback modes Screw terminal for 4 external trigger connections Level control Microprocessor-controlled operation 4 levels of available pr

22、iority Can be muted from higher priority modules Can mute lower priority modules Block Diagram 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500; Fax: 201-934-9832; Printed in Taiwan.0209 2002 Bogen Communications, Inc. 54-2080-01R2 Specifications subject to change without notice. Tone-Tr

23、igger Terminal Strip External contact closures that are connected here trigger tone playback. Level Controls Controls output level of module tones. Front Panel Callouts GAINMUTING MUTE IN MUTE OUT BUS ASSIGNMENT PRIORITY LEVEL BUS A BUS B MUTE LOW MUTE MED MUTE HIGH A B C D E F G H TONE SELECTION MICROPROCESSOR CONTROLLED TONE GENERATOR T1 T4 T3 T2 COM RadioFans.CN 收音机爱 好者资料库

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > Bogen

copyright@ 2008-2026 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号