1、Ceiling Speaker Enclosure & Tile Bridge Models RE84 and TB8 Installation and Use Manual UL LISTED (UUMW) Flush-Mounted Loudspeaker Installation For Use In Return Air Ceiling Plenum Spaces Enclosures (UL Listed)RE84 Intended for use with:TB8 (Tile Support Bridge) Listed by Underwriters Laboratories,

2、Inc. Category UUMW. Material and construction permits use where ceiling plenum is part of the air handling system. Compound knockout(s) provided for listed type metallic type fittings for 1/2 and 3/4 plenum rated cable and plenum whip flex conduit. Four horseshoe tab slots provided on each enclosure

3、 to mate with four horseshoe tabs on TB8 bridge eliminates the need for screws. Two seismic tie-off tabs and four tie-off tab slots with enclosure. RE84 Features RE84 TB8 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2108-01A 0404 Distribute

4、s the weight of a speaker, grille, and protective enclosure onto the ceiling grid. Four locator tabs to prevent sliding on ceiling tile. Four horseshoe tabs to mate with four horseshoe tab slots on enclosure. TB8 Features A Listed assembly requires that the enclosed loudspeaker is not exposed within

5、 the air handling plenum. Wiring, and/or conduit enclosure entry fittings, and installation must comply with local codes. Many local codes require a separate enclosure assembly with customer-supplied tie-off wire to secure the assembly to the top of the building structure. NOTE: All cable splices an

6、d connections to Speaker/Transformer pigtails must be made inside of Listed enclosure. NOTE: When the RE84 and the TB8 are installed together, the clearance holes on the TB8 are used during installation. However, when the TB8 is installed without the RE84, the threaded holes on the TB8 are used duri

7、ng installation. RadioFans.CN 收音机爱 好者资料库 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500, Fax: 201-934-9832, The RE84 and TB8 are warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser. Any part of the prod- uct cov

8、ered by this warranty that, with normal installation and use, becomes defec- tive will be repaired or replaced by Bogen, at our option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. The product will be returned to y

9、ou freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been remov

10、ed or defaced. THE FOREGOING LIMITED WARRANTY IS BOGENS SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASERS SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FIT- NESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS

11、CLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogens liability arising out of the manufacture, sale or supplying of products or their use or disposi- tion, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. In no event shall Bogen b

12、e liable for special, incidental or con- sequential damages (including, but not limited to, loss of profits, loss of data or loss of use damages) arising out of the manufacture, sale or supplying of products, even if Bogen has been advised of the possibility of such damages or losses. Some States do

13、 not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State. Products that are out of warranty will also be r

14、epaired by the Bogen Factory Service Department - same address as above or call 201-934-8500. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to parts and labor charges will be at the owne

15、rs expense. All returns require a Return Authorization number. Limited Warranty 1.Place ceiling tile with the finished side facing up over a large trash can (provides support and saves clean up time). 2.Cut hole in the center of the ceiling tile using the raw speaker as a template. 3.Position the ti

16、le bridge on the unfinished side of the ceiling tile and bend (4) locator tabs into tile opening to prevent sliding. 4.Install Ceiling Speaker assembly using (4) 8-32 screws and the threaded holes of the tile bridge as shown. (Screws are provided with Ceiling Speaker assembly). 1.Place ceiling tile

17、with the finished side facing up over a large trash can (provides support and saves clean up time). 2.Cut hole in the center of the ceiling tile using the raw speaker as a template. 3.Bend (4) horseshoe tabs up on tile bridge. 4.Position the tile bridge on the unfinished side of the ceiling tile and

18、 bend (4) locator tabs into tile opening to prevent sliding. 5.Slip seismic mounting tie-off tabs (2) through RE84 tie-off tab slots until they click into place and secure customer-supplied “tie-off” wire to tab. 6.Punch out knockout in the RE84 and install Listed metallic enclosure entry fitting to

19、 knockout to accommodate plenum cable or plenum whip and feed cable or whip through the knockout. 7.Install RE84 to tile bridge by orienting horseshoe tab slots (4) over horseshoe tabs (4) of bridge. 8.With pliers, twist horseshoe tabs (4) of tile bridge 1/2 turn, securing enclosure to bridge. 9.Scr

20、ew the Ceiling Speaker assembly to the RE84 using (4) 8-32 screws provided with the Ceiling Speaker assembly, sandwiching the TB8 and ceiling tile in between. The screws must go through the TB8 clearance holes as shown. (Screws anchor into the RE84). TB8 with RE84 InstallationTB8 Installation RadioFans.CN 收音机爱 好者资料库