1、Modular Lectern Array Models MLA40, MLA40T (Top) Instruction Manual 2000 Bogen Communications, Inc. All rights reserved. 54-5001-02R2 0007 Printed in U.S.A. RadioFans.CN 收音机爱 好者资料库 Notice Every effort was made to ensure that the information in this guide was complete and accurate at the time of prin

2、ting. However, this information is subject to change. Important Safety Information Always follow these basic safety precautions when installing and using the unit: 1.Read all instructions. 2.Follow all warnings and instructions marked on the product. 3.DO NOT block or cover the ventilation slots and

3、 openings. They prevent the product from overheating. DO NOT place the product in a separate enclosure or cabinet, unless proper ventilation is provided. 4. Never spill liquid on the product or drop objects into the ventilation slots and openings. Doing so may result in serious damage to the compone

4、nts. 5.Repair or service must be performed by a factory authorized repair facility. 6.The product is provided with a UL-CSA approved, 3-wire ground type plug. This is a safety feature. DO NOT defeat the safety purpose of the grounding type plug. DO NOT staple or otherwise attach the AC power supply

5、cord to building surfaces. 7.DO NOT use the product near water or in a wet or damp place (such as a wet basement). 8.DO NOT use extension cords. The product must be installed within 6 feet of a grounded outlet receptacle. 9.DO NOT install telephone wiring during a lightning storm. 10. DO NOT install

6、 telephone jacks in a wet location unless the jack is specifically designed for wet locations. 11. Never touch uninsulated wires or terminals, unless the line has been disconnected at the paging or controller interface. 12. Use caution when installing or modifying paging or control lines. Maintenanc

7、e & Service Caution There are no user-serviceable parts within the unit. Have all internal servicing performed by a qualified technician. The war- ranty will become void if repairs are made by other than the Bogen Service Department or an authorized service agency. Our Applications Engineering Depar

8、tment is available to help you troubleshoot problems with your Bogen equipment. Engineers are available from 8:30 AM to 6:00 PM, Eastern Standard Time. Phone 1-800-999-2809. Service can be obtained from our factory service department. No merchandise may be returned for repair without prior written a

9、uthorization. Please contact our factory service department at 1-800-999-2809 for a RA number. Only mer- chandise specified in the return authorization form can be returned to obtain warranty or non-warranty repair. When shipping your unit, pack your system well using the original shipping carton or

10、 a similar container and filler material to prevent damage in transit. Send the unit fully insured and pre- paid via UPS or other responsible carrier. Domestic and International Listings UL and CSA Listed. Page 2 of 8 RadioFans.CN 收音机爱 好者资料库 Introduction Bogens MLA lecterns represent an innovative a

11、pproach to podium and table-top lectern design. The multi-speaker array con- cept offers wider horizontal dispersion than traditional podium style lecterns. The modular design ensures flexibility. Performance advantages make it well suited for demanding applications in schools, churches, hotel and r

12、ental situations. Please take the time to read the instructions. You will receive the greatest benefit if you understand how the system oper- ates. System Overview The MLA40 consists of two modular components: the table-top portion and the podium base. The MLA40T is a table-top only lectern. The MLA

13、40 contains the amplifier and a 2 speaker array. The podium base contains a 4 speaker array. It connects electrically to the MLA40T table-top section. The MLA40T consists of the amplifier and a 2-speaker array. Note: The MLA40 can be unassembled so that it can also be used as a table-top only lecter

14、n, when needed. The amplifier is specifically designed to meet virtually all applications needs. It includes: 2 microphone inputs (Mic 1 and Lectern Mic) Aux input for a music source Tape out to a tape recorder or secondary amplifier Phantom power (DC power for certain types of microphones) Automati

15、c Level Control (ALC) Speech filter (reduces low-frequency feedback) Bass and Treble controls Switched and unswitched outputs for external systems. The product is shipped unassembled. Before attempting to assemble or operate the system, please read through these instructions to familiarize yourself

16、with the unit. Assembly Begin assembly by removing contents from cartons. Handle all parts carefully to avoid damage to finished surfaces. Carton 1 Contents (MLA40T/Top for table-top version, this is the only carton you will receive.): MLA40T lectern top section Gooseneck microphone Power cords (2)

17、4 plastic feet 4 Mounting bolts (1/4” x 20, round head) Instruction manual Carton 2 Contents (MLA40B/Base): Base with casters Speaker column Connecting plate 4 round head bolts (1/4” x 20) 4 flat head bolts (1/4” x 20) Page 3 of 8 RadioFans.CN 收音机爱 好者资料库 Follow the instructions below and refer to Fi

18、gure 1 to assemble the lectern. 1.Attach the column(s) to the base plate using 4 round head mounting bolts. The casters go toward the rear of the assembly. 2.Attach the connecting plate to the top of the speaker columns with 4 flat head bolts. Make sure the electrical connectors pass through the con

19、necting plates and are not crimped or pinched. 3.Connect the electrical connectors from the column into the jacks on the underside of the tabletop portion. 4.Set the table top section onto the connecting plate and secure with 4 round head bolts. 5.If using the MLA40 tabletop section alone or the MLA

20、40T, attach the 4 plastic feet to the underside of the tabletop using the 4 round head bolts. ELECTRICAL CONNECTORS TABLE TOP UNIT PLASTIC FOOT (SEE STEP 5) 4 MOUNTING BOLTS 1/4 x 20 FLAT HEAD 4 MOUNTING BOLTS 1/4 x 20 ROUND HEAD SPEAKER COLUMN 4 MOUNTING BOLTS 1/4 x 20 ROUND HEAD CONNECTING PLATE B

21、ASE (CASTERS IN BACK) Figure 1 Page 4 of 8 Operation Install Lectern Microphone The gooseneck lectern microphone plugs into the three-pin receptacle located on the top of the lectern. Connect Power Use the power cord supplied. Plug one end of the cord into the receptacle on the lectern labeled AC LI

22、NE INPUT. Plug the other end of the cord into a properly grounded three-wire AC receptacle. Caution: For safe operation, it is important to ground the amplifier properly. Do not attempt to defeat the grounding pin of the 3-wire plug. If you use a “pigtail” adapter to connect the plug to a two-wire o

23、utlet, you must ensure that the adapter is connected properly and that the outlet is properly grounded. Apply Power 1.Rotate the MIC and LECTERN MIC controls to their full counterclockwise positions. 2.Place the POWER switch in the ON (illuminated) position. Adjust Volume, Bass and Treble While spea

24、king into the lectern gooseneck microphone, rotate the LECTERN MIC control to a comfortable listening level. Rotate the BASS and TREBLE controls as necessary to enhance audio output. Adjusting Reading Lamp The lamp is controlled by the amplifier POWER switch. Use the switch on the lamp line cord to

25、set the lamp to always on or always off. Page 5 of 8 Additional Amplifier Functions Install Additional Microphone The lectern amplifier supports an external microphone. Plug the additional microphone into the 3-pin receptacle labeled MIC 1. Use the MIC 1 control to adjust the level. Aux Input The le

26、ctern amplifier can accommodate input from an auxiliary (music) source, such as a cassette deck. Connect the source via a mono RCA plug to the jack labeled AUX. Use the AUX control to adjust the level. Tape Out The lectern amplifier includes a Tape Out jack to permit recording. Connect a tape record

27、er using an RCA plug to the jack labeled TAPE OUT. Note that the level at this output is not affected by the volume controls. Phantom Power The lectern provides phantom power to condenser microphones. When shipped from the factory, phantom power is enabled. To turn off phantom power, use a phillips

28、head screwdriver to remove the locking tab(s) from the switches labeled PHANTOM. Place the switch in the OFF position. Replace the locking tab(s) to lock the switch in place. Speech Filter The Speech Filter can be used to reduce low-frequency feedback, most often caused by speaking too close to the

29、microphone. Place the switch labeled SPEECH FILTER in the ON position to enable the filter. Place the switch in the OFF position to bypass the filter. ALC The Automatic Level Control keeps the amplifier output constant when different people use the system. Place the switch labeled ALC in the IN posi

30、tion to enable the circuit. Place the switch in the OUT position to bypass the circuit. You should set the volume control for the person who speaks the quietest. The amplifier will then reduce the volume for louder persons. External Speakers The lectern permits the connection of an external speaker

31、system. The external system should be terminated in a 1/4” mono phone plug. To add an external system in addition to the lectern speakers, insert the phone plug into the jack labeled EXTER- NAL SPEAKER UNSWITCHED. To bypass the lectern speakers and use only the external system, insert the plug into

32、the jack labeled EXTERNAL SPEAKER SWITCHED. Important Note: The total external speaker impedance should not be less than 16 ohms. Accessory Outlet Caution: The POWERswitch does not control the auxiliary receptacle. An unswitched three-wire outlet (AUX POWER) is provided to power accessory equipment

33、(tape recorder, auxiliary source, etc.). Ensure that the equipment does not require more than 300 watts maximum. Use the accessory power cord to connect external equipment. Page 6 of 8 Feedback Control Feedback can occur when part of the output signal returns back to the input side of the amplifier.

34、 It is often caused by the microphone being too close or in front of the speakers. It can also result from the proximity effect, that is, when a person speaks too closely to a microphone. If you encounter feedback while using the lectern, try these techniques: If using the Lectern Microphone (goosen

35、eck mic): Reposition the microphone Reduce volume level Reduce the Treble level Enable the Speech Filter If using another microphone (Mic 1): Make sure that the person using the microphone stays in back of the lectern Reduce the volume level Reduce the Treble level Enable the Speech Filter Maintenan

36、ce The exterior surfaces should be cleaned with a soft cloth moistened with a mild soap solution. Do not use abrasives or solvent-based cleaners. Do not allow liquid to enter the black grille material. Service Caution: There are no user serviceable parts within the amplifier. To avoid an electric sh

37、ock, do not remove any of the amplifier covers. Have all internal servicing performed by a qualified technician. The warranty will become void if repairs are made by other than the Bogen Service Department or authorized service agency. In the event of difficulty, contact our techni- cal support grou

38、p, 1-800-999-2809, 8:30 AM until 6:00 PM, Eastern Standard Time, Monday through Friday. Page 7 of 8 Specifications Rated Power Output:40 watts RMS Frequency Response:20Hz to 20kHz 1dB -2dB rated power THD:Less than 0.5%, 20Hz to 20kHz -2dB 85mV Microphone:High-quality cardioid condenser microphone T

39、one Control Action:Treble 11dB 10kHz, Bass 11dB 100Hz ALC:Switch IN/OUT Speech Filter:-15dB 80Hz Volume Controls:MIC 1, Lectern Mic, Aux Tone Controls:Bass and Treble Switches:Phantom Power, ALC, Speech Filter, Power External Speaker Impedance:16 ohms (minimum) Tape Output:500mV Output Connections:T

40、ape Out RCA jack Speaker Out (2) 1/4” mono phone jack Auxiliary AC Power:300 watts max., unswitched Dimensions:MLA40 21-5/8” W x 48” H x 19-1/2” D MLA40T 21-5/8” W x 17” H x 19-1/2” D Shipping Weight:MLA40T (carton 1) 53 lbs. MLA40B (carton 2) 70 lbs. 50 Spring Street, Ramsey, NJ 07446 Tel. 201-934-8500, Fax: 201-934-9832 Web Site: / E-mail: