1、 2010 Bogen Communicat ions , Inc. Al l r ight s r es er v ed. 54-5946-01B 1002 Bogen Model PCMTIM Telephone Interface Module for Bogens PCM2000 Zone Paging System RadioFans.CN 收音机爱 好者资料库 PCMTIM 2 UL Approved Notice Every effort was made to ensure that the information in this manual was complete and
2、 accurate at the time of printing. However, information is subject to change. Federal Communications Commission (FCC) Statement (Part 68) This equipment is component registered with the Federal Communications Com- mission (FCC) in accordance with Part 68 of its rules. In compliance with the rules, b
3、e advised of the following: Registered equipment may not be used with Coin Telephone Lines. Equipment may be used with Party Lines in areas where state tariffs permit such connections and when equipment is adaptable for such service. This equipment is registered as follows: Registration Number - CD2
4、KOR-74854-PA-N Ringer Equivalence - 1.0B If trouble is experienced, the equipment should be disconnected from the interface to determine if this equipment, or the telephone line is the trouble source. If the equipment is determined to be malfunctioning, it should not be reconnected until re- pairs a
5、re effected. Repairs to this equipment, other than routine repairs, can be made only by the man- ufacturer or its authorized agents. If the equipment causes harm to the telephone network, the local telephone com- pany may temporarily discontinue your service and, if possible, notify you in ad- vance
6、. If advance notice is not practical, you will be notified as soon as possible. You will be given the opportunity to correct the problem and informed of your right to file a complaint with the FCC. The local telephone company may make changes in its facilities, operations, or pro- cedures that could
7、 affect the proper functioning of your equipment. If they do, you will be given adequate notice in writing to allow you an opportunity to maintain un- interrupted telephone service. RadioFans.CN 收音机爱 好者资料库 PCMTIM 3 Important Safety Information Always follow these basic safety precautions when instal
8、ling and using the system: 1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. DO NOT block or cover the ventilation slots and openings. They prevent the product from overheating. DO NOT place the product in a separate enclosure or cabinet, unle
9、ss proper ventilation is provided. 4. Never spill liquid on the product or drop objects into the ventilation slots and openings. Doing so may result in serious damage to the components. 5. Repair or service must be performed by a factory authorized repair facility. 6. The product is provided with a
10、UL-CUL approved, 3-wire ground type plug. This is a safety feature. DO NOT defeat the safety purpose of the grounding type plug. DO NOT staple or otherwise attach the AC power supply cord to building surfaces. 7. DO NOT use the product near water or in a wet or damp place (such as a wet basement). 8
11、. DO NOT use extension cords. The product must be installed within 6 feet of a grounded outlet receptacle. 9. DO NOT install telephone wiring during a lightning storm. 10. DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations. 11. Never touch uni
12、nsulated wires or terminals, unless the line has been discon- nected at the paging or controller interface. 12. Use caution when installing or modifying paging or control lines RadioFans.CN 收音机爱 好者资料库 PCMTIM 4 Contents Section 1 - Connecting the Telephone Interface Description.5 Interface.5 PBX Stat
13、ion Access/CO Line.6 PBX Loop Start Trunk Port .8 PBX Ground Start Trunk Port .10 Page Port Contact Closure .12 Page Port VOX.13 Override.15 Night Ring .16 Section 2 - Accessing Paging Zones Zone Accessing .17 To Page a Zone .17 To Make an All-Call Page .18 To Page a Zone Group .18 Code Calling .18
14、To Make a Pattern Code Call.19 To Make an Echo Code Call .20 Code Call Notes .20 Section 3 - BGM, Tone, Zone, & Zone Group Features BGM SRC Volume.21 Single Amp BGM/Page Connections.21 Tones.22 Tone Notes .23 Relay Contacts .23 Priority Order .23 Section 4 - Programming System Programming .24 Recomm
15、ended Initial Programming Procedure.24 To Program the PCM2000 System .24 Programming Paging Zone Groups.26 To Erase a Zone Group .26 Programming Signaling Zone Groups.26 Interface Default Timer .26 Interface VOX Timer .27 Dialing Timeout .27 Trunk Disconnect.27 Single Amp BGM Enable.27 Programming R
16、eal Time Clock .27 Clock Synchronization.28 Time-Triggered Events .28 Setup Tone .28 Reset Default Values.29 Feature Codes And Defaults .29 Connections to MIC using VAR1 .34 Using Night Ring with External Tone Generator .35 PCMTIM 5 Section 1 - Connecting The Telephone Interface Description The Boge
17、n Model PCMTIM is the Telephone Interface Module for the Bogen PCM Zone Paging System. Only one PCMTIM module is required per system (1 through 99 zones). The PCMTIM provides the telephone interface (including talk battery), night ringer input, emergency override input, background music source input
18、, and auxiliary relay contacts for the system. The module is also responsible for all tone signaling features. Controls are included for background music volume and tone volume. For instructions on the physical installation of the module to other system modules, refer to the documentation supplied w
19、ith the PCMCPU module. Interface The PCM connects to virtually any analog telephone port, including: PBX station lines and CO lines, PBX Loop Start Trunk Ports, PBX Ground Start Trunk Ports, and Page Ports (using contact closure or VOX activation). Interface installation consists of setting slide sw
20、itches and connecting with modular (RJ11) telephone plugs. Refer to the appropriate procedure on the following pages to connect the PCM2000 to your telephone system. In all cases, make sure that power is off before per- forming the installation. PCMTIM 6 PBX Station Access/CO line In the PBX Station
21、 Access/CO line configuration, the unit answers after the first full ring. As soon as it answers, the default timer is started. The default timer determines the maximum length of any page. When a paging zone is selected, the VOX timer is started (if enabled). This timer repeatedly resets as long as
22、audio is detected on the line. If no audio is detected within the VOX time period, the page will end. If audio con- tinues to be detected, the default timer will control page length. The unit will also respond to CPC pulses (a short loss of loop current when the call- ing party hangs up). When a CPC
23、 pulse is detected, the unit will immediately drop the line. 1. Make sure that power is off and all connections completed before proceeding. 2. Move the TELEPHONE INTERFACE SLIDE SWITCH on the module to the po- sition shown in the illustration below. PCMTIM 7 3. Use a modular RJ11 telephone cord (mi
24、nimum 2-conductor) to connect the mod- ule to the phone system. The two center conductors are Tip and Ring and are not polarity sensitive (see illustration below). Plug one end of the cord in to the PBX or CO modular jack and the other end in to the STATION jack on the module. 4. Finish all system c
25、onnections and connect power. 5. Set Default and VOX timers. (See Programming section for procedure.) NOTE: The default timeout is factory set to 30 seconds, and the VOX timeout is set to 6 seconds. If both the default and VOX timers are inhibited, the only way to dis- connect the system from the st
26、ation line is the CPC pulse. (Locking tab on back) The center two contacts connect to Tip & Ring of the PCMTIM. They are not polarity sensitive. PCMTIM 8 PBX Loop Start Trunk Port In the PBX Loop Start Trunk Port configuration, the unit supplies a 48V talk battery and detects loop current. There are
27、 two modes of operation for Loop Start Trunk. When the unit detects a loop resistance between Tip and Ring, it activates. When the loop opens, the page ends. When the Trunk Disconnect feature is inhibited (factory default), the VOX and De- fault timers are not used. If the Trunk Disconnect feature i
28、s enabled, the unit will operate as above, except it will also provide a one-second hook flash if the page is still active when the VOX and/or Default timers expire. Operation in this mode will enable the unit to automatically dis- connect itself from the loop start trunk of the PBX. This will preve
29、nt the paging sys- tem from being locked up indefinitely in the event a telephone is accidentally left off hook after a page has been completed. The feature codes are 014 to inhibit and 015 to enable this feature. The factory default feature code is 014 (inhibited). 1. Make sure that the power is OF
30、F and all connections completed before proceeding. 2. Move the TELEPHONE INTERFACE SLIDE SWITCHES on the module to the positions shown in the illustration below. PCMTIM 9 3. Use a modular telephone cord to connect the module to the phone system. Plug one end of the cord into the Loop Start Trunk (us
31、ing a modular jack) and the other end in to the TRUNK jack on the module. The two center conductors are Tip and Ring 48V DC and have a specific polar- ity. If the polarity of trunk is opposite, you can use a reversing modular cord to make the connection or reverse the connection through a modular bl
32、ock. Refer to the illustration below for more information. Caution: The polarity of the Tip & Ring contacts of the RJ11 jack for the Trunk and Override were chosen so that when a standard modular cord (one with the tops of both end plugs on the same side of the flat cable) is used to connect the PCM
33、 to a modular wall block, the modular block G (Tip) terminal will be positive with respect to the R (Ring) terminal. Because of variations in types of modular cords, and when stripping a modular cord for direct connection, always check the polarity of the center conductors or R & G terminals to dete
34、rmine Tip & Ring (the positive lead is Tip and the negative lead is Ring). 4. Finish all system wiring and connect power. 5. Set VOX and Default times if the Trunk Disconnect feature (previously described) has been enabled. (Locking tab on back) This contact connects to PCMTIM Ring (negative). This
35、contact connects to PCMTIM Tip (positive). PCMTIM 10 PBX Ground Start Trunk Port In the PBX Ground Start Trunk Port configuration, the unit supplies 48V talk battery and detects loop current. When the ground start trunk grounds the PCMs Ring, the PCM responds by closing the connection to its Tip, wh
36、ich completes the ac- cess procedure. There are two disconnect modes for Ground Start Trunk. When the unit detects a loss of loop current between Tip and Ring, the page ends. If the Trunk Disconnect feature is inhibited (factory default), the VOX and Default timers are not used. If the Trunk Disconn
37、ect feature is enabled, the unit will operate as above, except it will also provide a one-second hook flash if the page is still active when the VOX and/or Default timers expire. Operation in this mode will enable the unit to auto- matically disconnect itself from the loop start trunk of the PBX. Th
38、is will prevent the paging system from being locked up indefinitely in the event a telephone is acci- dentally left off hook after a page has been completed. The feature codes are 014 to inhibit and 015 to enable this feature. The factory default feature code is 014 (in- hibited). 1. Make sure that
39、the power is OFF and all connection completed before proceeding. 2. Move the TELEPHONE INTERFACE SLIDE SWITCHES on the module to the positions shown in the illustration below. PCMTIM 11 3. Use a modular telephone cord to connect the module to the phone system. Plug one end of the cord into the Ground Start Trunk (using a modular jack) and the other end in to the TRUNK