1、Power Vector Mixer Model VMIX Installation and Use Manual 2005 Bogen Communic ations, Inc . All rights reserved. Spec if ic ations subj ec t to c hange without notic e. 54-2134-01C 1204 RadioFans.CN 收音机爱 好者资料库 Notice Every effort was made to ensure that the information in this guide was complete and
2、 accurate at the time of printing. However, information is subject to change. Important Safety Information WARNING:To Reduce The Risk of Fire Or Electric Shock, Do Not Expose This Apparatus To Rain Or Moisture. Always follow these basic safety precautions when installing and using the unit: 1.Read t
3、hese instructions. 2.Keep these instructions. 3.Heed all warnings. 4.Follow all instructions. 5.Do not use this apparatus near water. The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus. 6. Clean only with dr
4、y cloth. 7.DO NOT block any ventilation openings. Install in accordance with the manufacturers instructions. 8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.Do not defeat the safety purpose of the polari
5、zed or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician fo
6、r replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Only use attachments/accessories specified by the manufacturer. 12. Unplug this apparatus during lig
7、htning storms or when unused for long periods of time. 13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the ap
8、paratus has been exposed to rain or moisture, does not operate normally, or has been dropped. IMPORTANT CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. The lightning flash with arrowhead symbol,
9、within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to al
10、ert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. RadioFans.CN 收音机爱 好者资料库 Contents Page(s) PANEL DESCRIPTIONS.2-3 VMIX Front Panel .2 VMIX Rear Panel.3 INSTALLATION .4 Package Contents .4 Mounting .4 Rack Mounti
11、ng .4 Shelf/Table Mounting .4 Module Installation .4 MODULES .5 Output Modules .5 Functionality .5 Input Modules .5 Functionality .5 Priorities .5 CONNECTIONS .6-7 Unbalanced Output .6 Balanced Output .6 Remote Volume Control .6 Bridging .6 Mute Control.7 System Expansion of Power Vector Mixers .7 O
12、PERATION .8-9 Front Panel Controls red indicates clipping of the input signal. 3. Treble Control Controls the amount of cut or boost of treble frequencies above 10 kHz. 4. LED Output Meter An 11-segment LED output level meter monitors the output level of the mixer. 5. Master Volume Control Controls
13、overall level of mixed input signals. 6. Power Indicator An LED indicates AC power status. 7. Bass Control Controls the amount of cut or boost of bass frequencies below 100 Hz. 8. Average/Peak Switch This switch determines whether the LED Output Meter registers the average or peak level of the mixer
14、s output. 9. Power Switch Controls AC power to the mixer. 2 Panel Descriptions VMIX Rear Panel 1. AC Receptacle A grounded, unswitched AC convenience receptacle with a 500W maximum capacity is provided for external equipment. 2. Unbalanced Output Jack Provides an unbalanced output for connection to
15、an auxiliary or high-impedance input. 3. Bridging Jack An RCA connector that allows the bridging of Power Vector products together for system expansion. 4. Remote Volume Control Terminals Three terminals are provided for connection to a Bogen Model RVCP, Remote Volume Control Panel, to control the m
16、ixers motorized Master Volume Control. 5. Low-Cut Switch A slide switch (located in module bay 6) that allows roll off of frequencies below 125 Hz. 6. Tone Control Bypass Switch A slide switch (located in module bay 6) that allows the effects of the bass and treble controls to be bypassed. 7. AC Lin
17、e Cord and Circuit Breaker A grounded, 3-wire AC line cord provides power to the mixer and is protected by a resettable circuit breaker. 8. Balanced Out Level Switch Three-position slide switch that selects the signal level of the balanced output. 9. Balanced Out Terminals Provides a balanced transf
18、ormer-isolated output with selectable output levels. 10. Mute Control Terminals Provides access to mute buses for external control and system expansion. 11. Module Bays The mixer has eight module bays, all of which can accommodate input modules, with two bays (bays 7 and 8) that can accommodate eith
19、er input or output modules. 3 Installation Package Contents Power Vector Mixer Module Covers (8) Instruction Manual 12 mm Module Cover Screws (16) Mounting Rack Mounting When stacking equipment in a rack, the mixer should either be on the bottom of the stack or above equipment that does not produce
20、heat. A rack mount bracket kit (model RPK87) is available for the Power Vector mixer. Shelf/Table Mounting When using a shelf or table mount, the mixer should stand alone with no equipment on top of it or below it. If the mixer must be stacked with other equipment, care must be taken to ensure that
21、all the minimum clear- ance distances are met and that the equipment below the mixer produces little significant heat. Rubber feet are installed on the mixer to allow it to be placed on a tabletop. Module Installation Eight module bays are available to accept Bogens new advanced input modules. Modul
22、e bays 7 Exclusion of Certain Damages 13 The Bogen VMIX is wa rra nte d to b e f re e f rom d e f e c ts in ma te ria l a nd work ma nship f or thre e (3) ye a rs f rom the d a te of sa le to the origina l purc ha se r. Any pa rt of the prod uc t c ove re d b y this wa rra nty tha t, with norma l in
23、sta lla tion a nd use , b e c ome s d e f e c tive (a s c onf irme d b y Boge n upon inspe c tion) d uring the a pplic a b le wa rra nty pe riod , will b e re pa ire d or re pla c e d b y Boge n, a t Boge n s option, provid e d the prod uc t is shippe d insure d a nd pre pa id to: Boge n Fa c tory S
24、e rvic e De pa rtme nt, 50 Spring Stre e t, Ra mse y, NJ 07446, USA. Re pa ire d or re pla c e me nt prod uc t will b e re turne d to you f re ight pre pa id . This wa rra nty d oe s not e xte nd to a ny of our prod uc ts tha t ha ve b e e n sub j e c te d to a b use , misuse , imprope r stora ge ,
25、ne gle c t, a c c id e nt, imprope r insta lla tion or ha ve b e e n mod if ie d or re pa ire d or a lte re d in a ny ma nne r wha tsoe ve r, or whe re the se ria l numb e r or d a te c od e ha s b e e n re move d or d e f a c e d . THE FOREGOING LIMITED WARRANTY IS BOGENS SOLE AND EXCLUSIVE WARRANT
26、Y AND THE PURCHASERS SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS- CLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Boge ns lia b ility a
27、 rising out of the ma nuf a c ture , sa le or supplying of prod uc ts or the ir use or d isposition, whe the r b a se d upon wa rra nty, c ontra c t, tort or othe rwise , sha ll b e limite d to the pric e of the prod uc t. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DA
28、MAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some Sta te s d o not a llow the e xc lusion or limita tion of inc i
29、d e nta l or c onse que ntia l d a ma ge s, so the a b ove limita tion or e xc lusion ma y not a pply to you. This wa rra nty give s you spe c if ic le ga l rights, a nd you ma y a lso ha ve othe r rights whic h va ry f rom Sta te to Sta te . Prod uc ts tha t a re out of wa rra nty will a lso b e re
30、 pa ire d b y the Boge n Fa c tory Se rvic e De pa rtme nt sa me a d d re ss a s a b ove or c a ll 201-934-8500. The pa rts a nd la b or involve d in the se re pa irs a re wa rra nte d f or 90 d a ys whe n re pa ire d b y the Boge n Fa c tory Se rvic e De pa rtme nt. All shipping c ha rge s in a d d
31、 ition to pa rts a nd la b or c ha rge s will b e a t the owne rs e xpe nse . All re turns re quire a Re turn Authoriza tion numb e r. For most e f f ic ie nt wa rra nty or re pa ir se rvic e , ple a se inc lud e a d e sc ription of the f a ilure . 12/2008 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500 Fax: 201-934-9832