《Rotel-RKF-100-OM 电路图 维修手册.pdf》由会员分享,可在线阅读,更多相关《Rotel-RKF-100-OM 电路图 维修手册.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、Owners manual RFK-100 Cooling Fan Kit Owners manual Manuel dutilisation Manuale Di Istruzioni Anvndarmanual Manual de Instrucciones Bedienungsanleitung Gebruiksaanwijzing RKF-100 Cooling Fan Kit Kit de Ventilation Kit ventole di raffreddamento Flktsystem Kit de Ventilacin Lfter-Kit Koelventilator ee
2、nheid RadioFans.CN 收音机爱 好者资料库 9. Do not use attachments not recommended in this owners manual as they may cause hazards. 10. Do not use the equipment near water; for example near a bathtub, washbowl, kitchen sink, a wet basement, swimming pool, etc. This product is meant for indoor use only. 11. Do
3、not place the product on an unstable cart, stand tripod, bracket or table. The equipment is heavy and should it fall, it could cause serious injury to a person and/or serious damage to the equipment. Caution For Installation 1. The dealership from which you purchased the product is an expert on cust
4、om installation procedures and can provide invaluable advice to help you make an aesthetically pleasing and trouble free installation. Caution For Connections 1. Connect this equipment only to the type of AC power source as marked on the unit. Always route AC power cords so they are not likely to be
5、 walked on, or tripped over, or where they may be pinched by items placed on or against them. Always pay particular attention to cords at plugs and/or convenience receptacles, and at the point where they exit from the product. 2. Do not defeat the inherent design features of the polarized plug. Non-
6、polarized line cord adapters will defeat the safety provided by the polarized AC plug. If the plug should fail to fi t, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding-type plug. If you use this product in a country which only has two slott
7、ed receptacles in the house, you must use a three-pin adapter plug to earth ground which is the “E” (earth pin) of the power cord connected to this product. 3. Do not overload wall outlets, extension or integral convenience receptacles, as this could result in a risk of fi re or shock. Operating Vol
8、tage The Fan System is factory-set for 110V, 120V or 230V AC operation at either 50 or 60 Hz, according to the country for which the unit was manufactured (230V in European Union countries, in compliance with CE regulations). The operating voltage cannot be changed by the user and any attempt to do
9、so will void the warranty. Thank you so much for your decision to purchase the model RKF-100 Cooling Fan Kit. We take enormous pride in the design and build quality of all of our products and we are confi dent that they will provide you with many years of enjoyable and product will trouble-free serv
10、ice. Should you have any need to call upon our services please feel free to contact us at the address shown at the end of this booklet; or, of course, you can contact the dealership from which you purchased the product. Fill out and send in the owners registration card packed with the RKF-100. Also
11、be sure to keep the original sales receipt. It is your best record of the date of purchase, which you will need in the event warranty service is ever required. Safety Instructions 1. Important Safety Instructions! Please read all the safety and operating instructions shown in this manual before oper
12、ating this equipment. 2. The lightning fl ash within an equilateral triangle shown below is intended to alert you to the presence of uninsulated dangerous voltage within the products enclosure that may be of suffi cient magnitude to constitute an electric shock. 3. The exclamation point within an eq
13、uilateral triangle shown above is intended to alert you to the presence of important operating and maintenance (servicing) instructions in the literature accompanying this appliance. 4. Please retain this manual in a safe place for future reference about safety and operating matters. 5. Adhere to al
14、l warnings and follow all operating instructions. 6. Warning: To reduce the risk of fi re or electrical shock, do not expose this equipment to rain or moisture. There are no user serviceable parts inside. Refer servicing to qualifi ed personnel. 7. Caution: To prevent electrical shock do not use thi
15、s (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure. 8. For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time, it is recommended that you unp
16、lug the unit from the wall outlet. This will prevent damage to the product due to lightning or power line surges. AVAVIS IS WAWARNIRNINGNGSHSHOCOCK K HAHAZAZARD RD - DODO NONOT T OPOPENEN RIRISQSQUEUE DEDE CHCHOCOC ELELECECTRTRONONIQIQUEUE -N-NE E PAPAS S OUOUVRVRIRIR RKF-100 Cooling Fan Kit2 Rotel
17、products are designed to comply with international directives on the Restriction of Hazardous Substances (RoHS) in electrical and electronic equipment and the disposal of Waste Electrical and Electronic Equipment (WEEE). The crossed wheelie bin symbol indicates compliance and that the products must
18、be appropriately recycled or processed in accordance with these directives. RadioFans.CN 收音机爱 好者资料库 Trigger In/Out 12VDC Mode With the mode switch in the 12V position, and the in input being used, the RKF-100 will move into its auto mode whenever a 6V to 15V input signal is supplied and the prescrib
19、ed initial temperature has been reached. Should you want to use one or more RKF-100s within the same location you can synchronize the units by using the sync switch. For this situation you should use the out jack from one unit (which then becomes the master) and go into the in jack for the second un
20、it (which then becomes the slave). The two units will now be in sync and will start to work in unison once the prescribed initial temperature of the master unit has been reached. Note that in this type of multi-unit installation all of the internal temperature sensors of the slave units are defeated
21、. Fan Auto-On Temperature This switch enables you to pre-select one of two temperature settings for activating the RKF-100. The low setting is 95 degrees Fahrenheit (35 degree Celsius) and the high setting is 104 degrees Fahrenheit (40 degrees Celsius). This important feature ensures that the fans o
22、nly work above the selected ambient temperature. If you want to exhaust the hot air to the outside you will need to remove the two plugs and attach fl exible tubing (not included with the unit). Please see page 4 for a fuller description of this feature. Fill out and send in the owners registration
23、card packed with the RKF-100. Also be sure to keep the original sales receipt. It is your best record of the date of purchase, which you will need in the event warranty service is ever required. Care of the Product Clean the product by dusting with a dry cloth. Do not permit objects of any kind to b
24、e pushed and/or fall into the product through the enclosure openings. General Description The RKF-100 is a multi-directional fan system that uses three 4.75-inch (120 mm) whisper quiet fans, the speeds of which are governed by thermal sensing circuitry. The RKF-100 is designed to be used in three di
25、fferent formats -intake/blow/exhaust air. The required mode can be confi gured locally according to the cooling requirements of your system. The RKF-100 has many other features and functions that are all described in the following pages. Front Panel Description The (removable) rack mountable front p
26、anel houses a switch for controlling the on/off and auto functions. A blue LED indicates when the units fans are actually working. Behind the grille front is a removable air-fi lter pad. It is important to note that the only time the switch needs to be in the on position is during an initial test wh
27、en the fans will be operating at their maximum speed. Once the RKF-100 has completed its test, it is recommended that the switch be placed in its auto position. In this mode neither the fans nor the LED will operate until the selected ambient temperature is reached. Rear Panel Description The follow
28、ing description identifi es each of the main controls /connections and follows the rear panel from left to right. Temperature Sensor This input enables you to connect the (supplied) pigtail sensing cord. The magnetized head should be placed on the hot spot of your installation whereupon it will meas
29、ure the ambient temperature, which in turn will govern the speed of the three fans. Please note that there is also an in-built sensing device located on the underside of the chassis that is by-passed if the pigtail sensor is used. If the pigtail sensor is not used, then the in-built sensor will auto
30、matically activate once the selected minimum temperature has been reached. 3 EnglishRadioFans.CN 收音机爱 好者资料库 2 SCREW PLASTIC COVER OVER TOP COVER VENTS 3 SQUEEZE FOAM CYLINDERS AND INSERT IN BOTH REAR HOLES TO BLOCK AIR 1 LOOSEN SCREWS ON BOTH SIDES AND LOWER INSIDE FAN ASSEMBLY TO BOTTOM POSITION AN
31、D RETIGHTEN Front Exhaust 1 LOOSEN SCREWS ON BOTH SIDES AND RAISE INSIDE FAN ASSEMBLY TO TOP POSITION AND RETIGHTEN SCREW PLASTIC COVER OVER BOTTOM COVER VENTS 2 SQUEEZE FOAM CYLINDERS AND INSERT IN BOTH REAR HOLES TO BLOCK AIR 3 Top Exhaust (Front Entry) REMOVE TOP COVER AND PLACE FOAM BLOCK BEHIND
32、 FRONT PANEL TO BLOCK AIR FLOW 2 SQUEEZE FOAM CYLINDERS AND INSERT IN BOTH REAR HOLES TO BLOCK AIR 3 1 LOOSEN SCREWS ON BOTH SIDES AND RAISE INSIDE FAN ASSEMBLY TO TOP POSITION AND RETIGHTEN Top Exhaust (Bottom Entry) LOOSEN SCREWS ON BOTH SIDES AND LOWER INSIDE FAN ASSEMBLY TO BOTTOM POSITION AND R
33、ETIGHTEN 1 REMOVE TOP COVER AND PLACE FOAM BLOCK BEHIND FRONT PANEL TO BLOCK AIR FLOW 2 REPLACE TOP COVER AND SCREW PLASTIC COVER OVER AIR VENTS 3 SCREW AIR TUBING IN REAR PANEL HOLE FOR TWO TURNS TO SECURE. USE TWO TUBES FOR MAXIMUM VENTING OR BLOCK AIR IN SECOND HOLE WITH FOAM CYLINDER AS SHOWN AB
34、OVE. 4 Rear Exhaust How To Confi gure The RKF-100 For Different Air-Direction Flow The RKF-100 is a versatile system that enables you to confi gure the direction of the airfl ow in many different ways according to the specifi c needs of your installation. Be sure to disconnect the power supply befor
35、e removing the top cover. RKF-100 Cooling Fan Kit4 10. Ne pas utiliser cet appareil prs dune source deau ; par exemple, une baignoire, une douche, un vier de cuisine, un sol constamment humide, une piscine, etc. Cet appareil ne doit tre imprativement utilis quen intrieur. 11. Ne pas poser cet appare
36、il sur un support instable, un trpied, un support quelconque ou une table. Cet appareil est particulirement lourd et, en tombant, il peut causer de srieuses blessures une personne tout en se retrouvant srieusement ou mme dfi nitivement endommag. Prcautions pour linstallation 1. Le revendeur auprs du
37、quel vous vous tes procur cet appareil est un spcialiste, expert dans les installations personnalises. Il pourra donc vous prodiguer de trs prcieux conseils pour une intgration discrte de cet appareil, avec lassurance de son fonctionnement optimal. Prcautions concernant les branchements 1. Branchez
38、cet appareil sur une source de courant correspondant exactement aux caractristiques indiques sur lappareil mme. Toujours disposer les cbles dalimentation secteur de telle manire quon ne puisse pas marcher dessus, les craser, et vrifi er quon ne les ait pas pincs entre deux appareils. Vrifi er notamm
39、ent la qualit des prises, des contacts, et la position des cbles la sortie des appareils. 2. Ne jamais modifi er la prise dalimentation. Certains cbles-rallonge font perdre les caractristiques correctes et la scurit des cbles dalimentation dorigine. En cas de dfectuosit de la prise, contactez immdia
40、tement un lectricien agr. Ne pas changer la prise secteur et notamment ne pas liminer la prise de terre associe. Si votre prise murale ne comporte que deux broches, vous devez utiliser un adaptateur spcial possdant une troisime broche (repre E ou T ) relie la terre, et donc relie aussi cet appareil.
41、 3. Ne surchargez jamais les prises murales ou mme les blocs multiprises ventuellement utiliss. Cela entrane de grands risques dincendie, ou mme dlectrocution. Tension dalimentation secteur Ce kit de ventilation est rgl en usine pour fonctionner sur la tension secteur de votre pays, soir 110 V, 120
42、V ou 230 V, et 50 ou 60 Hz (230 V dans les pays de lUnion Europenne, selon les normes CE). Cette tension dalimentation ne peut tre modifi e par lutilisateur, et toute tentative dans ce sens annule immdiatement la garantie. Nous vous remercions vivement pour lachat de ce kit de ventilation modle RKF-
43、100. Nous prenons un soin tout particulier quant la conception et la qualit de fabrication de tous nos produits, et nous sommes certains que cet appareil vous donnera des annes de satisfaction et de fonctionnement sans problme. En cas de problme, nhsitez pas contacter votre revendeur agr Rotel. De p
44、lus amples dtails concernant les conditions de garantie offertes par Rotel se trouvent la fi n de ce manuel dutilisation. Instructions importantes concernant la scurit 1. Instructions importantes concernant la scurit ! Veuillez lire trs attentivement les paragraphes qui suivent et le manuel dutilisa
45、tion avant de faire fonctionner lappareil. 2. Lclair dans un triangle quilatral indique la prsence interne de tensions lectriques leves susceptibles de prsenter des risques graves dlectrocution. 3. Le point dexclamation dans un triangle quilatral indique lutilisateur la prsence de conseils et dinfor
46、mations importantes dans le manuel dutilisation accompagnant lappareil. Leur lecture est imprative. 4. Conservez soigneusement ce livret pour le consulter nouveau pour de futures rfrences. 5. Tous les conseils de scurit doivent tre soigneusement respects. 6. Attention : Pour rduire tout risque dlect
47、risation ou dincendie, ne pas exposer lappareil une source humide ou la pluie. Il ny a lintrieur aucune pice susceptible dtre modifi e par lutilisateur. Adressez-vous imprativement une personne qualifi e. 7. Attention Pour viter tout risque dlectrisation, ne pas utiliser sa prise avec un cordon-rall
48、onge, une prise multiple ou tout autre adaptateur, moins que tous les contacts soient prsents et puissent tre insrs fond dans les logements correspondants (pas de partie mtallique visible). 8. titre de protection supplmentaire, pendant un orage ou pendant une longue priode de non-utilisation, il est
49、 recommand de dbrancher cet appareil de sa prise dalimentation murale. Cela permet dviter tout dommage pouvant rsulter dune surtension passagre, notamment pendant les orages. 9. Ne pas utiliser de dispositifs de fi xation autres que ceux indiqus dans ce manuel, afi n dviter tout risque de mauvais fonctionnement ou de blessure. AVAVIS IS WAWARNIRNINGNGSHSHOCOCK K HAHAZAZARD RD - DODO NONOT T OPOPENEN RIRISQSQUEUE DEDE CHCHOCOC ELELECECTRTRONONIQIQUEUE -N-NE E PAPAS S OUOUVRVRIRIR 5 Franais Tous les appareils Rotel