1、Owners Manual RLC-1040 Power Conditioner RadioFans.CN 收音机爱 好者资料库 2RLC-1040 Power Conditioner Inspect the line cords. telephone/data cords, or DSS/Cable TV coaxial cables connected to this device to ensure they remain fully pushed in or attached, and that they are not frayed or otherwise damaged. Imm

2、ediately stop using the component and have it inspected and/or serviced by a qualified service agency if: The power supply cord or plug has been damaged. Objects have fallen or liquid has been spilled into the unit. The unit has been exposed to rain. The unit shows signs of improper operation The un

3、it has been dropped or damaged in any way Place the unit on a fixed, level surface strong enough to support its weight. Do not place it on a moveable cart that could tip over. Important Safety Information WARNING: There are no user serviceable parts inside. Refer all servicing to qualified service p

4、ersonnel. WARNING: To reduce the risk of fire or electric shock, be sure that the apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus. Do not use this product in an environment where the relative humidity ma

5、y exceed 95% (non-condensing). Do not allow foreign objects to get into the enclosure. If the unit is exposed to moisture, or a foreign object gets into the enclosure, immediately disconnect the power cord from the wall. Take the unit to a qualified service person for inspection and necessary repair

6、s. Read all the instructions before connecting or operating the component. Keep this manual so you can refer to these safety instructions. Heed all warnings and safety information in these instructions and on the product itself. Follow all operating instructions. Unplug this device from the wall out

7、let before cleaning. Clean the enclosure only with a dry cloth or a vacuum cleaner. Note: A product that is meant for uninterrupted service and for some specific reason, such as the possibility of the loss of an authorization code for a cable TV converter, is not intended to be unplugged by the user

8、 for cleaning or any other purpose, may exclude the reference to unplugging this device. You must allow 10 cm or 4 inches of unobstructed clearance around the unit. Do not place the unit on a bed, sofa, rug, or similar surface that could block the ventilation slots. If the component is placed in a b

9、ookcase or cabinet, there must be ventilation of the cabinet to allow proper cooling. Keep the component away from radiators, heat registers, stoves, or any other appliance that produces heat. The unit must be connected to a power supply only of the type and voltage specified on the rear panel of th

10、e unit. Do not use a plug adapter which defeats the ground pin of the AC plug. Connect the component to the power outlet only with the supplied power supply cable or an exact equivalent. Do not modify the supplied cable in any way. Do not attempt to defeat grounding and/or polarization provisions. D

11、o not use extension cords. Do not route the power cord where it will be crushed, pinched, bent at severe angles, exposed to heat, or damaged in any way. Pay particular attention to the power cord at the plug and where it connects to the back of the unit. After connecting other devices to this device

12、, do not push the rear of the device up against any surface (wall or shelving unit), as this may create an undesired bend in the power cords which may break the wire strands of the cord. Although this device provides protection against electrical surges, when connecting an outside antenna or cable s

13、ystem to devices connected to this device, ensure the antenna or cable system is grounded so as to provide additional protection against voltage surges and static charges in accordance with Section 810 of the National Electric Code, ANSI/NFPA No.70 or later (see illustration). This device provides a

14、 grounding lug at the rear panel for grounding the device to an external Transient Voltage Surge Suppression (TVSS) device. Ensure this connection is made in accordance with the instructions provided by the TVSS device. This device employs Metal Oxide Varisters (MOVs), and other circuitry to protect

15、 against lightning and other sources of voltage surges and sags. It is not necessary to turn this device or the devices connected to this device, off during a lighting storm. Do not locate outside antenna systems near overhead power lines, or other electric light or power circuits, or where it may f

16、all or otherwise come in contact with these power sources. Do not allow the ladder being used, or the antenna itself to come into contact with these power sources, as such contact may be fatal. Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure

17、the total load to this device does not exceed that which is listed in the Specifications section of this manual. Federal Communications Commission (FCC) Compliance Information This device complies with Part 68 and Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) Th

18、is device must not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. As required, the bottom of this equipment contains, among other information, the Registration Number and Ringer Equivalence Number (REN

19、) for this equipment. If requested, this information must be provided to the telephone company. RadioFans.CN 收音机爱 好者资料库 3English Front and Rear Panel Controls and Connections Rack Ear Mounting RadioFans.CN 收音机爱 好者资料库 4RLC-1040 Power Conditioner About Rotel A family whose passionate interest in music

20、 led them to manufacture high fi delity components of uncompromising quality founded Rotel over 40 years ago. Over the years that passion has remained undiminished and the goal of provid- ing exceptional value for audiophiles and music lovers regardless of their budget, is shared by all Rotel employ

21、ees. Rotels reputation for excellence has been earned through hundreds of good reviews and awards from the most respected reviewers in the industry, who listen to music every day. Their comments keep the company true to its goal the pursuit of equipment that is musical, reliable and af- fordable. Al

22、l of us at Rotel thank you for buying this product and hope it will bring you many hours of enjoyment. Getting Started Thank you for purchasing the Rotel RLC-1040 Power Conditioner. When used in a high-quality music or home theater system, your Rotel power conditioner will protect your high performa

23、nce audio and video components from damaging power surges, spikes and lightning. Protection is guaranteed. Isolated noise fi lter banks and automatic voltage regulation will eliminate power as a source of audio and video signal degrada- tion. Phone-line surge protection jacks will stop surges travel

24、ing over phone lines. Digital satellite system, cable modem, and CATV coaxial cable lines are equally protected. With the RLC-1040 you can enjoy your home theater experience with the peace of mind that performance is optimized and protection is guaranteed. Features Automatic Voltage Regulation (AVR)

25、 - The RLC-1040 is unique in that it provides automatic voltage regulation, which is engaged to correct low and high voltage conditions. All equipment connected to the RLC-1040 is protected against these undesired voltage fluctuations, thus prolonging the life of the equipment. Low voltage condition

26、s can also negatively impact video quality. Consequently this feature may help improve picture quality if power line voltage is low. Surge Protection - The RLC-1040 provides guaranteed protection against damaging surges, spikes and even lightning. It not only provides protection from surges from AC

27、power lines, it also protects against surges from system data lines including COAX and telephone lines. With the RLC-1040 all your equipment is protected. Isolated Noise Filter Banks - The RLC-1040 eliminates electromagnetic and radio frequency interference (EMI/RFI) that, when severe enough, can ne

28、gatively impact sound and video quality. Each filter bank is electrically isolated from each other to prevent noise generated by one component from polluting other connected components. This noise filtering lets your system perform to its maximum capabilities. DC Trigger - When connected to a com- p

29、onent that provides a DC trigger, that component controls the turning on and off of the delayed outlet. The RLC-1040 also allows that DC signal to pass through to another connected component. Sequenced Turn ON/OFF - This feature ensures that connected equipment is powered- up/down in the proper orde

30、r and with the right amount of delay between the stages. It allows the user to program a delay into the sequence of from 0 to 12 seconds. This delay eliminates transient noises that can affect connected components. Contents Important Safety Information .2 Front and Rear Panel Controls and Connection

31、s 3 Rack Ear Mounting 3 About Rotel .4 Getting Started .4 Features 4 Parts List 5 A Few Precautions .5 Power Capacity 5 Placement 5 Front Panel .5 FILTERING Status Indicator 1 5 LINE OK Status Indicator 2 5 WIRING OK Indicator 3 5 OVERLOAD Status Indicator 4 5 Backlit LCD Display 5 5 LINE TRIM Statu

32、s Indicator 6 5 DELAYED ON Status Indicator 7 6 SWITCHED ON Status Indicator 8 6 LINE BOOST Status Indicator 9 6 On/Off Switch 0 6 SETUP Button - 6 SELECT Button = 6 Rear Panel .6 AC-Power Outlets q 6 Surge Protected COAX/RF Connectors w 6 SYSTEM GROUND Screw e 6 CIRCUIT BREAKER r 6 Input Power Conn

33、ector t 7 Surge Protected Telephone Jacks y 7 DC TRIGGER Jacks u 7 Installation .7 Placement 7 Rack Mounting 7 Making Connections .7 Power Input Connection t 7 Turning on the RLC-1040 0 7 Component Connection q e 7 Setting Up the RLC-1040 .8 Dimmer Function 8 AVR Range Function 8 Delay Time Function

34、 8 Beeper Function 8 Language Function 8 Status and Information Screens .9 Power Screen 9 Vout / Iout Screen 9 Vin / Freq Screen 9 Serial Number / Firmware Screen 9 Troubleshooting .9 The RLC-1040 will not turn on. 9 The overload LED is lit. 9 “Wiring OK Indicator” LED is not illuminated. 9 The Line

35、 Boost and Line Trim LEDs are fl ashing. 9 Technical Support 9 Limited Warranty .10 Specifi cations .10 5English LCD Display - The LCD displays shows important information including voltage in (line voltage) and voltage out, frequency, and load. Additionally, the display is used to program features

36、such as the delay or dimmer settings. All information in the display can be shown in English, French, or Spanish. Overload Indicator - The Overload Indicator lights up if the power requirements of the equipment connected to the RLC-1040 is too great. Removable Support Feet - Feet can be unscrewed an

37、d removed to save space when the RLC-1040 is rack mounted. Parts List The RLC-1040 Power Conditioner includes the parts listed below. If any items are missing, please contact your authorized Rotel dealer. 1 Power Conditioner 1 Input Power Cord 2 Coaxial cables 1 Telephone cable 2 Rack-mount ears 1 U

38、ser manual 1 Equipment Protection Policy Sheet 1 Warranty Registration Card A Few Precautions Please read this manual carefully. In addition to installation and operating instructions, it also provides important safety information. It is very important that you have read and understand all of the sa

39、fety information located at the front of this manual. If you have any questions about the safety information, or are concerned that your home may not be properly wired for this equip- ment, please contact a qualifi ed and licensed electrician.Please contact your authorized Rotel dealer for answers t

40、o any questions you might have. In addition, all of us at Rotel welcome your questions and comments. Save the RLC-1040 shipping carton and pack- ing material for future use. Shipping or mov- ing the RLC-1040 in anything other than the original packing material may result in severe damage. Be sure to

41、 keep the original sales receipt. It is your best record of the date of purchase, which you will need in the event warranty service is ever required. Power Capacity The RLC-1040 Power Conditioner is rated for 1440 watts (continuous). It has been designed, however, to support current surges that are

42、much higher than its continuous power rating. The RLC-1040 is capable of supplying the dynamic peak current draws required by any component designed to work on a 15 amp circuit. Despite their nameplate power ratings, high performance A/V equipment draw much less than their listed power ratings. The

43、RLC-1040 can inform the user how much of the power capacity is available as equipment is connected to the unit. Placement The RLC-1040 weighs approximately 20 pounds. Keep this in mind when selecting an installation location. Make sure that the shelf or cabinet can support its weight. Proper install

44、ation of your new Power Condi- tioner is important. If the unit is being mounted in a standard 19” rack, see the Rack Mounting section of this manual. Front Panel See the illustration on page 3. FILTERING Status Indicator 1 When lit, this notifi es the user that the Electromag- netic Interference/Ra

45、dio Frequency Interference (EMI/RFI) noise reduction circuit is active. LINE OK Status Indicator 2 When lit, this indicates that the voltage from the wall outlet is within acceptable range. If this indicator is not lit, the Automatic Voltage Regulation circuit is active and is correcting high or low

46、 voltage levels to maintain safe voltage conditions for the connected components. WIRING OK Indicator 3 When this indicator is lit, the wall outlet the RLC-1040 is plugged into is properly wired. If it is not lit one of three wiring problems exists in the building wiring circuit: missing ground, ove

47、rloaded neutral, or reversed polarity. An electrician should be consulted to resolve the problem. OVERLOAD Status Indicator 4 When lit this indicates that the unit is overloaded; unplug some of the equipment connected to the unit until the indicator is no longer lit. Backlit LCD Display 5 Provides s

48、tatus information about the RLC-1040 and the equipment plugged into it. The infor- mation in the Display can be shown in English, French, or Spanish. The brightness of the display and other front panel indicators can also be dimmed or even turned off. See the information in the Dimmer Menu section of this manual. LINE TRIM Status Indicator