《meguro_mak-6581_service_manual.pdf》由会员分享,可在线阅读,更多相关《meguro_mak-6581_service_manual.pdf(94页珍藏版)》请在收音机爱好者资料库上搜索。
1、 1 Instruction ManualInstruction Manual Audio AnalyzerAudio Analyzer Classification No. 1056Classification No. 1056- -821821- -001001 MEGURO ELECTRONICS CORPORATIONMEGURO ELECTRONICS CORPORATION 4 4- -1111- -1, MINAMIKASE, SAIWAI1, MINAMIKASE, SAIWAI- -KU, KAWASAKI 212KU, KAWASAKI 212- -0055, JAPAN0
2、055, JAPAN TEL : 044 ( 589 ) 0823TEL : 044 ( 589 ) 0823 FAX : 044 ( 589 ) 0825FAX : 044 ( 589 ) 0825 2 PRECAUTIONS FOR USEPRECAUTIONS FOR USE 1. The AC line voltage of this unit is set using the line voltage selector located on the rear panel. Verify that this has been set properly before applying p
3、ower. 2. Before turning the power switch ON, make sure that the meters are mechanically zeroed. 3. This unit uses a memory backup battery. Therefore, if the unit is not being used for a long period, the battery may become discharged. For this reason, the unit should be turned on occasionally to main
4、tain the battery charge. 4. Since this instrument uses a high-sensitivity input circuit, its use near strong electric or electromagnetic fields should be avoided. 5. Since this unit uses reed relays, it should not be subjected to excessive shock. 3 Table of ContentsTable of Contents 1 1 O OUTLINEUTL
5、INE . 5 5 1.1 GENERAL DESCRIPTION . 5 1.2 FEATURES . 5 1.3 ACCESSORIES . 6 2 2 SPECIFICATIONSSPECIFICATIONS . 7 7 2.1 OSCILLATOR . 7 2.2 VOLTAGE SETTING . 8 2.3 DISTORTION MEASUREMENT . 8 2.4 S/N MEASUREMENT . 8 2.5 GENERAL SPECIFICATIONS . 9 3 3 PANEL DISTORTIONPANEL DISTORTION . 1111 3.1 FRONT PAN
6、EL DESCRIPTION . 11 3.2 REAR PANEL DESCRIPTION . 15 4 4 OPERATIONOPERATION . 1717 4.1 PREPARATIONS FOR USE . 17 4.2 OSCILLATOR OPERATION . 17 4.3 MEASUREMENT SECTION OPERATION . 22 4.4 PRESS FUNCTION . 25 5 5 MEASUREMENT METHODMEASUREMENT METHOD . 3333 5.1 DISTORTION MEASUREMENT USING THE INTERNAL O
7、SCILLATOR . 33 5.2 DISTORTION MEASUREMENT USING AN EXTERNAL SIGNAL . 35 5.3 LEVEL MEASUREMENTS . 35 5.4 S/N MEASUREMENT . 36 6 6 REMOTE CONTROL (OPTIREMOTE CONTROL (OPTION)ON) . 3737 6.1 REMOTE CONTROL FUNCTION . 37 6.2 CONNECTIONS . 37 6.3 OPERATION . 37 6.4 REMOTE CONTROL (WITHOUT USING AN OPTION)
8、 . 38 7 7 GPGP- -IBIB. 4848 4 7.1 GENERAL DESCRIPTION . 48 7.2 FEATURES . 48 8 8 INTERFACEINTERFACE . 4949 8.1 INTERFACE FUNCTIONS . 49 8.2 INTERFACE ELECTRICAL SPECIFICATIONS. 49 9 9 OPEROPERATIONATION . 5050 9.1 FRONT PANEL CONTROLS AND CORRESPONDING COMMANDS . 50 9.2 GP-IB INTERFACE RELATED REAR
9、PANEL LOCATIONS . 51 9.3 PANEL DESCRIPTIONS . 52 9.4 PRECAUTIONS BEFORE USE . 53 9.5 OPERATION PROCEDURE . 54 1010 CONNECTOR PIN ARRANGCONNECTOR PIN ARRANGEMENTEMENT . 7272 1111 PROGRAM EXAMPLEPROGRAM EXAMPLE . 7373 5 1 1 OUTLINEOUTLINE 1.1 General Description The MAK-6581 is an audio analyzer which
10、 incorporates the functions of an audio oscillator, distortion meter, S/N meter and AC voltmeter in a single instrument. The oscillator frequency and distortion meter fundamental tuned frequency are linked automatically, making it into an effective linked distortion meter, and, with all its other fu
11、nctions, this instrument can replace a variety of individual audio measuring instruments. In setting frequency and output levels, LED displays are used to indicate setting values and two meters are used to indicate the input level and measured values, thereby increasing measurement efficiency. The u
12、se of microprocessor technology dramatically enhances ease of use, and a full range of memory/recall functions in addition to a remote control function and furthermore, the GPIB function is included. 1.2 Features The use of numerical and incrementing keys greatly simplifies the task of setting oscil
13、lator frequencies and output levels. The oscillator output level may be set in units of volts, dBV or dBm, and conversions between units can be made as desired. An input level meter and measurement meter are provided to enable independent displays of input levels and distortion or other measured val
14、ues simultaneously. By using an input ALC circuit, the distortion measurement setting level is not adversely affected by residual noise caused by input level fluctuations. Fast-acting response in the fundamental elimination circuit ensures reduced measurement times. A variety of filters, namely, 400
15、Hz highpass, 30/80kHz lowpass and WTD (weighted, JIS A), usable in all measuring mode are provided as standard. The indicating circuit of the measurement system uses an rms value response circuit with excellent frequency response, thus achieving accurate measured results. 6 All panel operating funct
16、ions may be stored in memory (up to 100 steps), these steps being recallable whenever desired. (10 memory address 10 step numbers for a total of 100 steps. Step number expansion may be made up 100 steps.) In making S/N measurements, an automatic signal level hold function and signal off function ope
17、rate to increase ease of operation. All panel key function may be operated by means of a rear panel remote control connector, enabling external control. (A remote control box is optional.) With the GPIB function provided, including data output, in addition to remote control, it is possible to use th
18、e A/D outputs of the two meter indications. 1.3 Accessories Item Model Qty Remarks Input / Output cable 060-1800 1 BNC-to- alligator clips Input / Output cable MC-2051B 1 With 2 BNC connectors Fuse 2 2A, or 1A ; slow-blow type Power cable 1 with AC plug Instruction Manual MAK-6581 1 Option : BNC Ada
19、pter (Binding post / BNC plug) Model 1296 7 2 2 SPECIFICATIONSSPECIFICATIONS 2.1 Oscillator Frequency Range 5.0Hz199.9kHz Accuracy 2% of setting value Output Level range 0.238mV2.37Vrms into a 600 load 0.238mV0.999mVrms in 0.001mV steps 1.00mV9.99mVrms in 0.01mV steps 10.0mV99.9mVrms in 0.1mV steps
20、100mV999mVrms in 1mV steps 1.00V2.37Vrms in 0.01V steps -72.5dB+7.5dB in 0.1dB steps -70.3dBm+9.7dBm in 0.1dBm steps Accuracy At 1kHz : -32.5dB+7.5dB : 0.2dB -32.6dB and below : 0.5dB Flatness 20Hz19.99kHz : 0.2dB 5.0Hz1999.9kHz : 0.5dB Distortion 20Hz10kHz -95dB (0.0018%), 80kHz BW 5.0Hz50kHz : -85
21、dB (0.0056%), 600kHz BW 50kHz1999.9kHz : -75dB (0.018%), 600kHz BW Impedance 600 1%, unbalanced (floating) 8 2.2 Voltage Setting Measurement range +40dB-90dB (100Vrms0.03mVrms) fullscale in 14 ranges Frequency characteristics 20Hz100kHz : 0.3dB 5.0Hz300kHz : 1.0dB 2.3 Distortion Measurement Measurem
22、ent frequency 5.0Hz199.9kHz Distortion measurement range -10dB-90dB (30%0.003%) fullscale with an input level of 1Vrms or greater. Fundamental elimination ratio 20Hz19.99kHz : 100dB or greater 5.0Hz50kHz 90dB or greater 50kHz199.9kHz : 80dB or greater Residual distortion For an input voltage of 1Vrm
23、s or greater : 20Hz10kHz -95dB (0.0018%), 80kHz BW 6.0Hz50kHz -85dB (0.0056%), 600kHz BW 5.0Hz199.9kHz -75dB (0.018%), 600kHz BW Input level range 0.1100Vrms (0.3100V fullscale) in six ranges 2.4 S/N Measurement Measurement range 0dB90dB fullscale (with an input level of 1Vrms or greater) Signal lev
24、el range 0.1V100Vrms Residual noise -100dB (10V) or less. 80kHz BW -90dB (32V) or less, 600kHz BW 9 2.5 General Specifications Input impedance 100k 1%, unbalanced Input capacitance 100pF or less Filters 400Hz highpass filter, 18dB / oct (all measurement modes) 30kHz lowpass filter, 18dB / oct (all m
25、easurement modes) 80kHz lowpass filter, 18dB / oct (all measurement modes) WTD (JIS A) (all measurement modes) Meters Input level meter : Average value response, rms value indication with V, db and dBm scales. Measurement meter : Rms value response, rms value indication (crest factor of 5 or below),
26、 with V, %, dB and dBm scales. Oscillator frequency, distortion Made by means of numerical entry in meter fundamental frequency combination with a cursor and and output level settings incrementing keys. AC Output 1Vrms / meter fullscale Output impedance : 1k, unbalanced DC Output 1VDC / meter fullsc
27、ale Output impedance : 1k, unbalanced Presets 1010 memory, maximum of 100 steps. All panel functions storable. Remote control All panel functions may be controlled remotely. An optional remote control box is usable to perform memory recall, incrementing of frequencies and output levels and up / down
28、 shifting of meter ranges. A GP-IB function provided. Backup battery N-SB3 10 Power supply 100/115/215/230VAC 10% (voltage is selected by means of a line voltage selector on the rear panel), 50/60Hz, approx. 53VA. Maximum dimensions Approx. 430(W)110(H)380(D)mm Weight Approx. 9.5kg 11 3 3 PANEL DIST
29、ORTION PANEL DISTORTION 3.1 Front Panel Description Fig. 1 Fig. 1 12 POWER Switch This is the power switch of the MAK-6581 FREQ. This key is used to set the oscillator output frequency and, when setting the distortion meter fundamental frequency, is pressed to specify the frequency mode. LEVEL This
30、key is pressed when setting the oscillator output level to specify the level mode. RCL This key is pressed to recall data from a desired memory address which has been previously stored. STO This key is pressed to store any desired panel measurement settings. Numerical Keys These numerical keys are u
31、sed to specify oscillator frequency, output level, and address numbers for recall and storage. Units Key a) kHz/dB This key is used to select the units as follows. Frequency mode : kHz Level mode : dB (dBV) b) Hz / dBm This key is pressed to select the units as follows. Frequency mode : Hz Level mod
32、e : dBm (600) c) V This key is pressed in the level mode to specify units of volts. d) mV This key is pressed in the level mode to specify units of millivolts. FREQUENCY / OUTPUT LEVEL This display indicates the oscillator or distortion meter fundamental frequency or oscillator output level. It cons
33、ists of a 3.5-digit display, unit indicators, and a cursor function which is used to indicate the digit which will be incremented or decremented. 13 INCREMENT These keys are used to increment or decrement the lower three digits of frequency and level values indicated on the display. The key is used to bring the cursor to the desired digit and the and keys are used to increase and decrease the value, respectively. MEMORY ADDRESS This is the memory address and step number display. STEP (RTN)