《Jvc-TSC-01-FANG-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-TSC-01-FANG-Service-Manual电路原理图.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALTS-C01FANGFAN UNITBASIC CHASSISCHNo. 52040May 2002COPYRIGHT 2002 VICTOR COMPANY OF JAPAN, LTD.TS-C01FANGTotal Mass : 1.1 k10715414638467.552.5160174MODEL No. IF-C01FANGFAN UNIT BFAN UNIT A(Unit : mm)TO FAN UNITCONTENTSa INSTRUCTIONS.2a PARTS LIST .32 No. 52040TS-C01FANGINSTRUCTIONSTS-C
2、01 FANGInstructions for AssemblyWARNINGOnly attach to the JVC specified PDP Monitor. Attachment to other objects could result in fire or damage.Only use the screws provided for assembly of this unit. Failure to do so could cause the Monitor to collapse or fall, resulting in injury or damage.Only use
3、 the screws provided. Failure to do so could cause the screws to interfere with the circuits, resulting in electric shock or damage to the monitor.Only use the wire clamp provided to keep the electric wires in place. Failure to do so could result in fire or damage when attaching to a wall unit.Plug
4、in the DC plug provided into its corresponding DC jack. Failure to do so could result in fire or damage due to inappropriate operation.Do not cover the ventilation areas of the Fan Unit and PDP Monitor. Failure to do so could result in fire and damage due to insufficient ventilation.Clean the ventil
5、ation areas of both the Fan Unit and PDP Monitor. Operation when the unit is covered in dust could result in fire or damage.Fan Unit Parts List;ATTENTION During assembly, be careful not to touch metal edges.qFan Unit A x 1wFan Unit B x 1DC plugeScrew x 8rWire Clamp X 10Non output terminalDC plug(Bla
6、ck) Length: 12mmOutput terminalDC jackS tight screwAssembly, Set Up Precautions 2002 VICTOR COMPANY OF JAPAN, LIMITEDVICTOR COMPANY OF JAPAN, LIMITEDFor more details, consult your local dealer.Printed in Japan LC21141-001AHow to assemble (Install the Fan Units before attaching in the wall or ceiling
7、 units.)1.Using four black screws provided e, affix Fan Unit A qto the rear right side of the PDP Monitor, as illustrated below.2.Using four black screws provided e, affix Fan Unit B wto the rear left side of the PDP Monitor, as illustrated below.3.Plug the DC plug for Fan Unit A qinto the OPTION te
8、rminal for the PDP Monitor.4.Plug the DC plug for Fan Unit B w into the DC jack for Fan Unit A, labeled “TO FAN UNIT”.5.Peel off the sticker attached to the wire clamp r, and attach to the PDP Monitor to fix the wires in place, attach tothe spots illustrated below.6.Turn the PDP Monitor on and confi
9、rm that the fans are operating.PDP Monitor OPTION terminalPDP MonitorFan Unit A qFan Unit B wATTENTIONWhen using in the upright position (illustrated above), ensure Fan Unit A, located on the rear right of the PDP Monitor, is facing upward.Attach using the black screws provided eUpright position.ATT
10、ENTIONWhen attaching on to a wall or ceiling unit, be careful that the wires do not get tangled and that the DC plug does not come loose.Attach using the black screws provided eTS-C01FANGNo. 52040 3H18549 PARTS LIST! Ref.No. Part No. Part Name Description LocalPARTS LISTFAN UNIT A FAN UNIT BDC PLUG1
11、. OUTER 2. CENTER +FAN FAN +DC OUT DC OUT +DC IN DC IN +DC JACK (PIN)REDBLACKDC JACK (OUTER)FAN FAN +DC IN DC PLUG1. OUTER 2. CENTER +DC IN +REDBLACK81(7T O F AN UNIT92MODEL No . IF-C01F ANG3)%4* 5 & 6 $ !01 YAC3608-001 FAN CASE For FAN UNIT A2 YAC3608-002 FAN CASE For FAN UNIT B3 YAC3616-001 FAN BA
12、SE (X 2)4 YAC4570-001 FAN COVER (X 2)5 YAC4574-001 DC JACK BKT6 YDD4974-002 FAN PWB ASSY (X 2)7 YWA1221-00A DC JACK8 YAB4571-001 DC PLUG CORD For FAN UNIT A9 YAB4571-002 DC PLUG CORD For FAN UNIT B10 YAM4572-001 STUD (X 8)11 ASB-320 STUD (X 4)12 KF-21 CORD BUSH (X 2)14 QYSDST3005M SCREW (X 8)15 QYSP
13、SPD3030Z SCREW (X 8)16 QYSBSB4012M SCREW (X 8)17 QRG039J-560 OM R (X 2) 56 3W J18 QAR0238-002 FAN (X 2)19 YAA4537-001 LABEL20 LC41402-002A CAUTION LABEL (X 2)LC21141-001 INST BOOKKAJ3613-001 PACKING CASELC32507-002A CARTON LABELPrinted in JapanVP0205SWTS-C01FANGVICTOR COMPANY OF JAPAN, LIMITEDHOME AV NETWORK BUSINESS UNIT 12, 3-chome, Moriya-cho, kanagawa-ku, Yokohama, kanagawa-prefecture, 221-8528, Japan