1、Published by KC-TE 0740 V&MA Printed in he Netherlands Subject to modication EN 3139 785 32971BDP7100/12BLU-RAY DISC PLAYER1 Technical Specications 2Location PCB Drawing 32 Safety Precautions 4Servicing Precautions 6ESD Precautions 7Handing optical pick-up 8Lead-Free Requirement 9 3 Disassembly Inst

2、ructions 104 Trouble Shooting 165 Firmware Upgrading 356 Block and Wiring Diagram 37Block Diagram 37Wiring Diagram 387 Circuit Diagrams and PCB Layouts 39S.M.P.S (S.M.P.S PCB) 39SMP8634 DDR SDRAM (Main PCB) 40SMP8634 Flash Memory (Main PCB) 41Nand Flash, Controller (Main PCB) 42SMP8634 Power, Decoup

3、ling (Main PCB) 43Sil9134 HDMI (Main PCB) 44HDMI-CEC (Main PCB) 45Ethernet contol (Main PCB) 46Audio (Main PCB) 477 Circuit Diagrams and PCB Layouts 48SMP8634 GPIO Control, JTAG, Debug (Main PCB) 48MM1757 Analog Video Out (Main PCB) 49PATA Control (Main PCB) 50Power (Main PCB) 51PCI, ETC (Main PCB)

4、52 Front Interface (Main PCB) 53Front (Front PCB) 54Power Key (Power Key PCB) 557 PCB Layouts 56Main PCB Component Side-1 56Main PCB Component Side-2 57Main PCB Conductor Side-2 58S.M.P.S PCB Component Side 59S.M.P.S PCB Conductor Side 60Front PCB Component Side andConductor Side 61Power Key PCB Com

5、ponent Side andConductor Side 628 Exploded View and Service Parts List 63Cabinet Assembly 63Service Parts List 64 9 Directions for Use 6510 Revision List 67Copyright 2007 Philips Consumer Electronics B.V. Eindhoven, The Netherlands.All rights reserved. No part of this publication may be reproduced,

6、stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permission of Philips.Version 1.1Contents Page Contents PageEN 2 3139 785 329701. Technical Specications1. Technical Specication1.1 GeneralMains voltage : 22

7、0V 230VMains frequency : 50HzPower consumption : 29 WStandby Power consumption : -60dB on all output Bandwidth Y : 5.7MHz 3dB (480i)11.6MHz 3dB (480p)26.1MHz 1dB (720p/1080i)Bandwidth PbPr : 2.9MHz 3dB (480i)5.8MHz 3dB (480p)13MHz 1dB (720p/1080i)Supports: : BD: 1080i, 720p, 480p, 480iDVD : 480p, 48

8、0i1.8.2 Composite Video (CVBS):Output Impedance : 75SNR Luminance : -65dBSNR Chrominance AM : -59dBSNR Chrominance PM : -49dBBandwidth Luminance : 4.2MHz 1dBSupports: : BD: 480i / DVD: 480i1.8.3 S-Video:Output Impedance : 75SNR Y : -65dBSNR C AM : -59dBSNR C PM : -49dBBandwidth Y : 4.2MHz 1dBSupport

9、s: : BD: 480i / DVD: 480i1.9 Audio PerformanceOutput voltage : 2Vrms 5%Channel unbalance (1kHz) : 115dBDynamic range 1kHz : 95dBDistortion and noise 1kHz : 50dB1.10 Laser Output Power & Wavelength1.10.1 Blu-Ray DiscOutput power : 0.35mW (single), 0.7mW (Dual)Wavelength : 405nm1.10.2 DVDOutput power

10、: 0.8mWWavelength : 650nm1.10.3 CDOutput power : 0.3mWWavelength : 780nmEN 33139 785 32970 1.Location PCB DrawingMAIN PCBS.M.P.S PCBBDP LOADER ASSY1.11 PCB LocationEN 4 3139 785 329702. Precautions2-1 Safety Precautions1) Before returning an instrument to the customer, always make a safety check of

11、the entire instrument, including, but not limited to, the following items:(1) Be sure that no built-in protective devices are defective or have been defeated during servicing. (1) Protective shields are provided to protect both the technician and the customer. Correctly replace all missing protectiv

12、e shields, including any removed for servicing convenience. (2) When reinstalling the chassis and/or other assembly in the cabinet, be sure to put back in place all protective devices, including, but not limited to, nonmetallic control knobs, insulating sh papers, adjustment and compartment covers/s

13、hields, and isolation resistor/capacitor networks. Do not operate this instrument or permit it to be operated without all protective devices correctly installed and functioning.(2) Be sure that there are no cabinet openings through which adults or children might be able to insert their ngers and con

14、tact a hazardous voltage. Such openings include, but are not limited to, excessively wide cabinet ventilation slots, and an improperly tted and/or incorrectly secured cabinet back cover.(3) Leakage Current Hot Check-With the instrument completely reassembled, plug the AC line cord directly into a 23

15、0V(220V 240V) AC outlet. (Do not use an isolation transformer during this test.) Use a leakage current tester or a metering system that complies with American National Standardsp institute (ANSI) C101.1 Leakage Current for Appliances and Underwriters Laboratories (UL) 1270 (40.7). With the instrumen

16、ts AC switch rst in the ON position and then in the OFF position, measure from a known earth ground (metal water pipe, conduit, etc.) to all exposed metal parts of the instrument (antennas, handle brackets, metal cabinets, screwheads, metallic overlays, control shafts, etc.), especially any exposed

17、metal parts that offer an electrical return path to the chassis. Any current measured must not exceed 0.5mA. Reverse the instrument power cord plug in the outlet and repeat the test. See Fig. 1-1.Any measurements not within the limits specied herein indicate a potential shock hazard that must be eli

18、minated before returning the instrument to the customer.Fig. 1-1 AC Leakage Test(4) Insulation Resistance Test Cold Check-(1) Unplug the power supply cord and connect a jumper wire between the two prongs of the plug. (2) Turn on the power switch of the instrument. (3) Measure the resistance with an

19、ohmmeter between the jumpered AC plug and all exposed metallic cabinet parts on the instrument, such as screwheads, antenna, control shafts, handle brackets, etc. When an exposed metallic part has a return path to the chassis, the reading should be between 1 and 5.2 megohm. When there is no return p

20、ath to the chassis, the reading must be innite. If the reading is not within the limits specied, there is the possibility of a shock hazard, and the instrument must be repaired and rechecked before it is returned to the customer. See Fig. 1-2.Fig. 1-2 Insulation Resistance Test2. PrecautionsEN 53139

21、 785 32970 2.Precautions2) Read and comply with all caution and safety related notes on or inside the cabinet, or on the chassis.3) Design Alteration Warning-Do not alter or add to the mechanical or electrical design of this instrument. Design alterations and additions, including but not limited to,

22、 circuit modications and the addition of items such as auxiliary audio output connections, might alter the safety characteristics of this instrument and create a hazard to the user. Any design alterations or additions will make you, the servicer, responsible for personal injury or property damage re

23、sulting therefrom.4) Observe original lead dress. Take extra care to assure correct lead dress in the following areas: (1) near sharp edges, (2) near thermally hot parts (be sure that leads and components do not touch thermally hot parts), (3) the AC supply, (4) high voltage, and (5) antenna wiring.

24、 Always inspect in all areas for pinched, out-of-place, or frayed wiring, Do not change spacing between a component and the printed-circuit board. Check the AC power cord for damage.5) Components, parts, and/or wiring that appear to have overheated or that are otherwise damaged should be replaced wi

25、th components, parts and/ or wiring that meet original specications. Additionally, determine the cause of overheating and/or damage and, if necessary, take corrective action to remove any potential safety hazard.6) Product Safety Notice-Some electrical and mechanical parts have special safety-relate

26、d characteristics which are often not evident from visual inspection, nor can the protection they give necessarily be obtained by replacing them with components rated for higher voltage, wattage, etc. Parts that have special safety characteristics are identied by shading, an ( )or a ( )on schematics

27、 and parts lists. Use of a substitute replacement that does not have the same safety characteristics as the recommended replacement part might create shock, re and/or other hazards. Product safety is under review continuously and new instructions are issued whenever appropriate.PrecautionsEN 6 3139

28、785 329702. PrecautionsCAUTION : Before servicing units covered by this service manual and its supplements, read and follow the Safety Precautions section of this manual.Note : If unforseen circumstances create conict between the following servicing precautions and any of the safety precautions, alw

29、ays follow the safety precautions.Remember: Safety First. 2-2-1 General Servicing Precautions (1) a. Always unplug the instruments AC powercord from the AC power source before (1) re-moving or reinstalling any component, circuit board, module or any other instrument assembly, (2) disconnecting any i

30、nstrument electrical plug or other electrical connection, (3) connecting a test substitute in parallel with an electrolytic ca pacitor in the instrument. b. Do not defeat any plug/socket B+ voltage interlocks with which instruments covered by this service manual might be equipped.c. Do not apply AC

31、power to this instrument and/or any of its electrical assemblies unless all solid-state device heat sinks are correctly installed.d. Always connect a test instruments ground lead to the instrument chassis ground before connecting the test instrument positive lead. Alwaysremove the test instrument gr

32、ound lead last.Note : Refer to the Safety Precautions section ground lead last. (2) The service precautions are indicated or printed on the cabinet, chassis or components. When servicing, follow the printed or indicated service precautions and service materials.(3) The components used in the unit ha

33、ve a specied ame resistance and dielectric strength. When replacing components, use components which have the same ratings. Components identied by shading, by ( ) or by ( ) in the circuit diagram are important for safety or for the characteristics of the unit. Always replace them with the exact repl

34、acement components.2-2 Servicing Precautions(4) An insulation tube or tape is sometimes used and some components are raised above the printed wiring board for safety. The internal wiring is sometimes clamped to prevent contact with heating components. Install such elements as they were.(5) After ser

35、vicing, always check that the removed screws, components, and wiring have been installed correctly and that the portion around the serviced part has not been damaged and so on. Further, check the insulation between the blades of the attachment plug and accessible conductive parts.2-2-2 Insulation Ch

36、ecking ProcedureDisconnect the attachment plug from the AC outlet and turn the power ON. Connect the insulation resist-ance meter (500V) to the blades of the attachment plug. The insulation resistance between each blade of the attachment plug and accessible conductive parts (see note) should be more

37、 than 1 Megohm.Note : Accessible conductive parts include metal panels,input terminals, earphone jacks, etc.EN 73139 785 32970 2.PrecautionsElectrostatically Sensitive Devices (ESD)Some semiconductor (solid state) devices can be dam-agedeasily by static electricity.Such components commonly are calle

38、d Electrostatically Sensitive Devices(ESD). Examples of typical ESD devices are integrated circuits and some eld-effect transistors and semiconductor chip components. Thefollowing techniques should be used to help reducethe incidence of component damage caused by static electricity.(1) Immediately b

39、efore handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be removed for potential shock reasons

40、 prior to applying power to the unit under test.(2) After removing an electrical assembly equipped with ESD devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.(3) Use only a grounded-tip soldering iron to sol

41、der or unsolder ESD devices.(4) Use only an anti-static solder removal devices. Some solder removal devices not classied as “anti-static” can generate electrical charges sufcient to damage ESD devices.(5) Do not use freon-propelled chemicals. These can generate electrical charges sufcient to damage

42、ESD devices.(6) Do not remove a replacement ESD device from its protective package until immediately before your are ready to install it.(Most replacement ESD devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive materials).(7) Immed

43、iately before removing the protective materials from the leads of a replacement ESD device, touch the protective material to the chassis or circuit assembly into which the device will be installed.2-3 ESD PrecautionsCAUTION : Be sure no power is applied to the chassis or circuit, and observe all oth

44、er safety precautions.(8) Minimize bodily motions when handling unpackaged replacement ESD devices. (Otherwise harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted oor can generate static electricity sufcient to damage an ESD device).EN 8 3

45、139 785 329702. Precautions2-4 Handling the optical pick-upThe laser diode in the optical pick up may suffer electrostatic breakdown because of potential static electricity from clothing and your body.The following method is recommended.(1) Place a conductive sheet on the work bench (The black sheet

46、 used for wrapping repair parts.)(2) Place the set on the conductive sheet so that the chassis is grounded to the sheet.(3) Place your hands on the conductive sheet (This gives them the same ground as the sheet.)(4) Remove the optical pick up block(5) Perform work on top of the conductive sheet. Be

47、careful not to let your clothes or any other static sources to touch the unit. Be sure to put on a wrist strap grounded to the sheet. Be sure to lay a conductive sheet made of copper etc. Which is grounded to the table.Fig.1-3(6) Short the short terminal on the PCB, which is inside the Pick-Up ASSY,

48、 before replacing the Pick- Up. (The short terminal is shorted when the Pick- Up Assy is being lifted or moved.)(7) After replacing the Pick-up, open the short terminal on the PCB.EN 93139 785 32970 2.Precautions2.5 Lead Free RequirementInformation about Lead-free produced setsPhilips CE is starting

49、 production of lead-free sets from 1.1.2005 onwards. INDENTIFICATION:Regardless of special logo (not always indicated) One must treat all sets from 1 Jan 2005 onwards, according next rules. Example S/N:Bottom line of typeplate gives a 14-digit S/N. Digit 5&6 is the year, digit 7&8 is the week number, so in this case 1991 wk 18So from 0501 onwards = from 1 Jan 2005 onwardsImportant note: In fact also products of year 2004 must be treated in this way as lon

展开阅读全文
相关资源
猜你喜欢
相关搜索

当前位置:首页 > 功放/音响/收扩 > Philips

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号