Classe-CAP150-int-sm维修电路图 手册.pdf

上传人: 文档编号:93039 上传时间:2020-10-18 格式:PDF 页数:21 大小:1.09MB
下载 相关 举报
Classe-CAP150-int-sm维修电路图 手册.pdf_第1页
第1页 / 共21页
Classe-CAP150-int-sm维修电路图 手册.pdf_第2页
第2页 / 共21页
Classe-CAP150-int-sm维修电路图 手册.pdf_第3页
第3页 / 共21页
亲,该文档总共21页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Classe-CAP150-int-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《Classe-CAP150-int-sm维修电路图 手册.pdf(21页珍藏版)》请在收音机爱好者资料库上搜索。

1、PRO-SVR_LEGACY Page 1 of 12 Date: August 22, 2007 Model Number: CAP-100 / CAP-150 Class Audio Inc. Subject: Service manual Class Audio, Inc. 5070 Franois Cusson Lachine, Qubec Canada H8T1B3, RadioFans.CN PRO-SVR_LEGACY Page 2 of 12 Table of Contents Introduction 3 Important Notes on Servicing 3 Orde

2、ring Replacement Parts 3 Block Diagrams 4 Start up Procedure 5 Protection Modes and Indicators 6 Troubleshooting Guide 7 Output Transistors Testing and Replacement 8 Calibrations and Adjustments 9 Parts List 10 Fuses 11 Voltage Change 12 Schematics 13 The contents of this document as well as the fil

3、es associated with it contain confidential information that is proprietary to Class Audio Incorporated and are intended solely for the purpose of servicing product. No part of its contents may be used, copied, disclosed, or conveyed to any party in any manner whatsoever without prior written permiss

4、ion from Class Audio Incorporated. RadioFans.CN PRO-SVR_LEGACY Page 3 of 12 Introduction Please read this manual carefully before commencing servicing! Only qualified and authorized personnel should attempt to service this product. The lightning flash with arrowhead symbol, within an equilateral tri

5、angle, is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presenc

6、e of important operating and maintenance (servicing) instructions. Class has a global product support network. For product assistance or to order replacement parts please contact your nearest service center always quoting the unit serial number. North America Phone: (978) 664-2870 E-mail: Europe Pho

7、ne: 44 (0) 1903 221 700 E-mail: Asia Phone: (852) 2790 8903 E-mail: classebwgroup.hk Rest of the World Phone: (514) 636-6384 E-mail: Important Notes on Servicing 1.ALWAYS observe ESD precautions when handling electronic modules or PCBAs. 2.NEVER exchange boards with a different revision number, unle

8、ss authorized by Class. 3.ALWAYS use Class original replacement parts. The use of generic parts may void the warranty of the unit. Ordering Replacement Parts There may be a delay in processing incomplete requests. Please be sure to include all required information. Remember to quote the serial numbe

9、r of the unit on all replacement part orders and the Class order number when returning defective parts for credit. RadioFans.CN PRO-SVR_LEGACY Page 4 of 12 Block diagrams RadioFans.CN PRO-SVR_LEGACY Page 5 of 12 Start Up Procedure When receiving a unit, an assiduous visual inspection must be perform

10、ed. Do not connect the unit without analysing the symptoms reported by the customer and the results of the inspection. Using the troubleshooting guide, find the problem and proceed to the repair. Once this step is done, follow these steps, known as the start-up procedure, to ensure that everything i

11、n the unit is in working condition. 1. Proceed with a post repair visual inspection. Take the time to check if every wire is reconnected properly, every screw is bolted on, no soldering and/or metal residues lying in the unit, every fuse has been replaced, etc. 2. Turn the bias trimpots, counter clo

12、ckwise until a click is heard. 3. Since there is no soft-start sequence of the CAP-100 / CAP-150, it is impossible to use a bypass to perform a slow start up. 4. Connect Main supply, and turn on the unit. 5. If one or more supply are not within specifications, return to the troubleshooting guide. 6.

13、 If every supply is within specifications, report to calibration and adjusments to adjust bias and DC offset. Note that bias can be adjusted to 20mV, and the following tests can be performed before the unit is send to the burn-in bench for a 24 hours warm-up. 7. Connect the unit to a load, and to a

14、source using single ended inputs. 8. Perform a test with a 200Hz, a 2kHz and a 20kHz tone, both sinus wave and square wave. Check the output with a oscilloscope, on 4 ohms and 8 ohms loads. Take special cares about oscillation and phase correlation between channels. 9. Connect the unit to a small sp

15、eaker, and short the input. Check for any noise. 10. Put the unit on a burn-in bench, and let it sit for 24 hours, then readjust bias. Let the unit on the burn- in bench for another 72 hours. 11. Redo steps 7 to 11 before shipping to the customer. RadioFans.CN PRO-SVR_LEGACY Page 6 of 12 Protection

16、Modes and Indicators The front LED display shows the status of the amplifier. When starting up normally, the CAP100 / CAP150 will show a FLASHING MUTE LED for about 20 sec. However, there is no protection on the CAP100 / CAP150. The CAP100 / CAP150 is equipped with four rail protection fuses. In the

17、 event that one or more of these fuses would blow, the technician will first need to identify and cure the cause of failure (please report to troubleshooting guide). When the cause has been identified, disconnect the unit from the system including the AC power. Remove the top cover and look for dama

18、ged or burned components. If no other components than the fuses appear to be damaged, the technician can then replace the broken fuses with the same value and rating (please report to fuses section). The rail fuses are located on the main board. When replacing fuses, please make sure that the fuse h

19、older are holding the fuses very tightly. A loose fuse holder can translate into distortion on top of the signal. RadioFans.CN PRO-SVR_LEGACY Page 7 of 12 Troubleshooting Guide Symptom Possible cause Unit won t turn on Check connections; Check fuses; Check soft-start circuit; Check relays; Check pow

20、er supply circuits (positive rail, negative rail, Mosfet supply). Smoked and/or burned components Check for short between components and ground; Check output transistors; Check output relays; Check power supply circuits (positive rail, negative rail, Mosfet supply). Blown fuses Check for short betwe

21、en fuse and ground; Check power supply circuits (positive rail, negative rail, Mosfet supply). No output Check connexions; Check output relays; Check power supply circuits (positive rail, negative rail, Mosfet supply); Check output transistors. Unit turn into protection Check for smoked and/or burne

22、d components; Check power supply circuits (positive rail, negative rail, Mosfet supply); Check source and load; Check protection circuit; Check sensor wires between sensor PCB and control PCB; Check outputs transistors and Mosfet drivers. Excessive buzz and/or hum Check electrical lines; Check for a

23、 ground loop in the system. Oscillation Check source; Check capacitors on main board; Check 4.7? resistor. Intermittent signal Check connections; Replace shield wires. RadioFans.CN PRO-SVR_LEGACY Page 8 of 12 Output Transistors Testing and Replacement PLEASE NOTE THAT THESE TESTS ARE ONLY EFFECTIVE

24、ON BIPOLAR TRANSISTORS. DO NOT PERFORM THESE TESTS ON MOSFET DEVICES, AS THEY ARE LIKELY TO BECOME SHORT DURING THE TEST. You should check all pin combinaisons, as there is a chance that only one side of the transistor is short. When replacing outputs transistors, the technician should first disconn

25、ect both outputs and main board to check if the blown outputs were caused by a faulty component on the amplifier s base. Blown output transistors should be replaced by kits, not individually. These kits contains matched transistors for both rails of one channel. When replacing blown output transisto

26、rs, you must also replace positive and negative Mosfet drivers and bias transistor. Carefully inspect 4.7? resistor and 10? soft start resistor, and replace if necessary. Replace any burnt component or board. Pins : 1 Base 2 Collector 3 Emitter You should have these results, if the transistor is goo

27、d. 2SC3264 (NPN) Positive lead Negative lead Result B C Conductive B E Conductive C B Infinite C E Infinite E B Infinite E C Infinite 2SA1295 (PNP) Positive lead Negative lead Result B C Infinite B E Infinite C B Conductive C E Infinite E B Conductive E C Infinite RadioFans.CN PRO-SVR_LEGACY Page 9

28、of 12 Calibrations and Adjustments Bias adjustment: Note: Bias adjustment should be made without any load connected to the amplifier s output, and no signal connected to the amplifier s input. 1. Since it is impossible to connect a multimeter to both emitter s resistors in order to measure and adjus

29、t bias without disassembling the heatsink from the chassis, we provided a test point to ease the bias procedure. It is located near the bias trimpot. 2. Connect the positive probe of a millivoltmeter to the test point and the negative probe to the positive speaker post of the channel to be adjusted.

30、 3. Turn trimpots counterclockwise until it reaches 0?. A click should be heard. 4. Turn on amplifier, and let it warm up for 15 minutes on idle. 5. Adjust trimpot to get a 20mV reading. 6. Let the amplifier warm up for a 24 hours period with signal and load. 7. Remove signal and load, and reconnect

31、 the multimeter. 8. Readjust to 24mV. DC offset: Note: DC offset adjustment should be made without any load connected to the amplifier s output, and no signal connected to the amplifier s input. On these units, DC offset can t be adjusted. Measure DC offset using a voltmeter connected to the output

32、posts, scale setted to mV. DC offset should be less than 10mV. RadioFans.CN PRO-SVR_LEGACY Page 10 of 12 Parts List This is not a detailed part list. It is a list of major chassis parts and PCBs. If you need to order a specific part, please contact Classe Audio with the part location, PCB number, an

33、d model and serial number of the unit. If you need a complete PCB, please replace the (x) in the Classe part number with the revision number printed on the board. Parts Description Classe part number B0F1X Complete PCB, input B0F1XR(x) B0F2X Complete PCB, supply B0F2XR(x) B0F3X Complete PCB, heatsin

34、k B0F3XR(x) B0F4X Complete PCB, amplifier B0F4XR(x) B0F5X Complete PCB, caps B0F5XR(x) B0F6X Complete PCB, preamp B0F6XR(x) B0F7X Complete PCB, front panel B0F7XR(x) B0F9X Complete PCB, phono B0F9XR(x) RadioFans.CN PRO-SVR_LEGACY Page 11 of 12 Fuses EXTRA PRECAUTIONS SHOULD BE TAKEN WHEN REPAIRING,

35、MODIFYING,OR TROUBLESHOOTING IN THE POWER SUPPLY AREA. UNIT MUST BE DISCONNECT FROM MAIN SOURCE AND CAPACITORS MUST BE DISCHARGED USING A 100W INCANDESCENT BULB. WHEN REPLACING FUSES, PLEASE MAKE SURE THAT THE FUSE HOLDERS ARE HOLDING THE FUSES VERY TIGHTLY. A LOOSE FUSE HOLDER CAN TRANSLATE INTO DI

36、STORTION ON TOP OF THE SIGNAL. CAP-100 Main fuses: For 100 120v units: 4A slo-blo, Classe part number GDC-4A For 220 240v units: 3.15A slo-blo, Classe part number GDC-3.15A The main fuse is located at the back of the unit, on the rear panel. CAP-150 Main fuses: For 100 120v units: 5A slo-blo, Classe

37、 part number GDC-5A For 220 240v units: 4A slo-blo, Classe part number GDC-4A The main fuse is located at the back of the unit, on the rear panel. Rail fuses: 4A, Classe part number GDB-4A The rail fuses are located on the heatsink board (B0F3X). Control board fuse: 0.75A, Classe part number 225.750

38、 The control board fuse is located on top of the supply board (B0F2X) Mosfet fuses: 0.50A, Classe part number 225.500 The Mosfet fuses are centered on the heatsink board (B0F3X) RadioFans.CN PRO-SVR_LEGACY Page 12 of 12 Voltage Change EXTRA PRECAUTIONS SHOULD BE TAKEN WHEN REPAIRING, MODIFYING,OR TR

39、OUBLESHOOTING IN THE POWER SUPPLY AREA. UNIT MUST BE DISCONNECT FROM MAIN SOURCE AND CAPACITORS MUST BE DISCHARGED USING A 100W INCANDESCENT BULB. 1. Set the jumper position according to the table below. 2. Replace the varistor, according to new line voltage, following Classe s recommendations. If v

40、aristor is not available, remove old varistor and leave it empty. Jumper positions, main transformer Mains Jumper 1 Jumper 2 Jumper 3 Varistor 100VAC A E F 221 120VAC A C D 221 220VAC B E - 391 / 441 240VAC B D - 391 / 441 Jumpers, auxiliary transformer Mains Position 1 Position 2 Position 3 Position 4 Position 5 100/120VAC In Out Out Out In 220/240VAC Out Out In Out Out RadioFans.CN B0F1XR02.sch-1 - Mon Aug 20 08:53:17 2007 RadioFans.CN B0F2XR04.sch-1 - Mon Aug 20 08:54:27 2007 RadioFans.CN RadioFans.CN RadioFans.CN RadioFans.CN RadioFans.CN RadioFans.CN RadioFans.CN RadioFans.CN

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > Classe

copyright@ 2008-2025 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号