Denon-AVRX6400H-avr-sm维修电路图 手册.pdf

上传人: 文档编号:93665 上传时间:2020-10-20 格式:PDF 页数:203 大小:22.11MB
下载 相关 举报
Denon-AVRX6400H-avr-sm维修电路图 手册.pdf_第1页
第1页 / 共203页
Denon-AVRX6400H-avr-sm维修电路图 手册.pdf_第2页
第2页 / 共203页
Denon-AVRX6400H-avr-sm维修电路图 手册.pdf_第3页
第3页 / 共203页
亲,该文档总共203页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Denon-AVRX6400H-avr-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《Denon-AVRX6400H-avr-sm维修电路图 手册.pdf(203页珍藏版)》请在收音机爱好者资料库上搜索。

1、START:|sX3k6VQNaf/6VbQg1Aav9Q=|NtOOpK8Hw7SVyAFQuznArZMqgzToOuTqeouhB6NC5/c=|XOIUVeyoWOE5XcWqSdEcbA=|:END INTEGRATED NETWORK AV RECEIVER AVR-X6400H Click here! On-line service parts list Online Parts List (P5 to P7) WEB owners manual (Release schedule) (July 2017) (July 2017) (September 2017) CAUTION

2、 IN SERVICING ELECTRICAL MECHANICAL REPAIR INFORMATION UPDATING Service Manual Ver. 1 Forpurposesofimprovement,specificationsanddesignaresubjecttochangewithoutnotice. Pleaseusethisservicemanualwithreferringtotheoperatinginstructionswithoutfail. Someillustrationsusinginthisservicemanualareslightlydif

3、ferentfromtheactualset. RadioFans.CN CAUTION IN SERVICING SAFETY PRECAUTIONS NOTE FOR SCHEMATIC DIAGRAM NOTE FOR PARTS LIST INSTRUCTIONS FOR HANDLING SEMICONDUCTORS AND OPTICAL UNIT Online Parts List Accessing the Parts List Logging in to New SDI and Accessing the Parts List Accessing the Part List

4、from the Model Asset Screen PRINTED CIRCUIT BOARDS Parts Table Downloading the Parts List as an Excel File Revision History Searching Part Numbers or Ref. Numbers CAUTION IN SERVICING. Initializing This Unit JIG FOR SERVICING 2 Caution in servicing ElectricalMechanicalRepair InformationUpdating Radi

5、oFans.CN The following items should be checked for continued protection of the customer and the service technician. Leakage current check Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage curren

6、t exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and standby mode), if applicab

7、le. CAUTION Please heed the following cautions and instructions during servic- ing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautions described in the

8、handling instructions. Cautions concerning electric shock! (1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing gloves when servicing w

9、hile the set is energized, or by unplugging the power cord when replacing parts, for example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufactured from sheet me

10、tal, there may be burrs on the edges of parts. The burrs could cause injury if fingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). Be sure to use pa

11、rts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were

12、 originally placed! For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mount- ed away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and hi

13、gh voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area a

14、round. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V in

15、sulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Many of the electric and the structu

16、ral parts used in the set have special safety properties. In most cases these properties are difficult to distinguish by sight, and the use of replacement parts with higher rat- ings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts w

17、ith safety properties are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams Indicated by the z mark. (2) Parts lists Indicated by the z mark. The use of parts

18、 other than the designated parts could cause electric shocks, fires or other dangerous situations. CAUTION Concerning important safety parts SAFETY PRECAUTIONS 3 Caution in servicing ElectricalMechanicalRepair InformationUpdating RadioFans.CN WARNING: Parts indicated by the z mark have critical char

19、acteristics. Use ONLY replacement parts recommended by the manufacturer. CAUTION: Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chass

20、is to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DO NOT return the set to the customer unless the problem is identified and remedied. NOTICE: ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNL

21、ESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. N INDICATES NANO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. 1. Parts indicated by nsp on this table cannot be supplied. 2. When ordering a part, make

22、a clear distinction between 1 and I (i) to avoid mis-supplying. 3. A part ordered without specifying its part number can not be supplied. 4. Part indicated by mark is not illustrated in the exploded view. WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement part

23、s recommended by the manufacturer. Electrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential differ- ence caused by electrostatic charge during unpacking or repair work. 1. Ground for Human Body Be sure to wear a grounding band (1 M ohm) that is properly grounded

24、to remove any static electricity that may be charged on the body. 2. Ground for Workbench Be sure to place a conductive sheet or copper plate with proper grounding (1 M ohm) on the work- bench or other surface, where the semi-conductors are to be placed. Because the static electricity charge on clot

25、hing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing CBA Grounding Band Conductive Sheet or Copper Plate 1M 1M CBA NOTE FOR SCHEMATIC DIAGRAM NOTE FOR PARTS LIST INSTRUCTIONS FOR HANDLING SEMICONDUCTORS AND OPTICAL UNIT 4 Caution in

26、servicing ElectricalMechanicalRepair InformationUpdating RadioFans.CN Online Parts List Accessing the Parts ListLogging in to New SDI and Accessing the Parts List (1) Click the URL link on the cover of the service manual. Examples of display NOTE : If the web browser does not open automatically, cop

27、y the URL and paste it into the address bar of the web browser and then press Enter. (2) When the login screen is displayed, enter your username and password. (3) Enter the 5 letters shown as the blue CAPTCHA code as single-byte characters. If the text is unclear, click Refresh to change the CAPTCHA

28、 code, and enter it again. (4) Press the Login button. (1) Access New SDI from the URL below. (2) When the login screen is displayed, enter your username and password. (3) Enter the 5 letters shown as the blue CAPTCHA code as single-byte characters. If the text is unclear, click Refresh to change th

29、e CAPTCHA code, and enter it again. (4) Press the Login button. (5) When the Home screen is displayed, click Advanced Search. (6) Enter the following search conditions and click Search. Keyword : Model name Brand : brand name Asset Type : Part list (7) Click the model name when the search results ar

30、e displayed. 5 Caution in servicing ElectricalMechanicalRepair InformationUpdating RadioFans.CN Downloading the Parts List as an Excel File Revision History (1) Displays the Parts List. Click the Download icon. (1) Click Revision history in the blue bar. The following details are displayed. Sheet :

31、Name of the changed sheet Description : Description of the changes Remarks : Destination, color information Factories : Factory number Ver : Version number after revision if changes were made to the parts list Date : Date of changes Accessing the Part List from the Model Asset Screen PRINTED CIRCUIT

32、 BOARDS Parts Table (1) Display Model Asset from New SDI. (2) Click the section displayed as Link to Part Lists under the model name. NOTE : If the Link to Parts List section is not displayed, download the parts table from the Asset list. (1) Display the Parts List. Click the PCB name in the blue ba

33、r to display the parts list for the board. Left and right arrow icons are displayed if the circuit board name does not fit in the blue bar. Click these icons to display a different part of the name when necessary. Icons to move the circuit board name left and right in the blue bar 6 Caution in servi

34、cing ElectricalMechanicalRepair InformationUpdating RadioFans.CN Searching Part Numbers or Ref. Numbers You can search a Parts List for part numbers or Ref. numbers. (1) Enter the part number or Ref. number in the search window of the Parts List, and press the search button. (2) The search results a

35、re displayed. The name of the sheet in which the search part is used and the parts line are displayed. (3) Next, click the Sheet section of the search results. (4) The Board Part Table opens and the line on which the searched part number appears is highlighted. 7 Caution in servicing ElectricalMecha

36、nicalRepair InformationUpdating RadioFans.CN Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the digital PCB. 1. Press the power button to turn off the power. 2. While holding down buttons CURSOR d and CURSOR f simultaneously, press the power butto

37、n to turn on the power. 3. Release the buttons after confirming that the display flashes at 1-second intervals. The unit is initialized. Use network initialization mode to initialize the network related settings. NOTE: If the unit fails to enter the service mode in step 3, repeat the procedure from

38、step 1. Initializing the device restores the customized settings to the factory settings. Write down your settings in advance and reconfigure the settings after initialization. Use the following jigs (extension cable kit) when repairing the PCBs. Order with your dealer for the jigs your dealer if ne

39、cessary. 8U-110084S : EXTENSION UNIT KIT : 1 Set (See JIG FOR SERVICING) CURSOR d CURSOR fX JIG FOR SERVICING Initializing This Unit CAUTION IN SERVICING. 8 Caution in servicing ElectricalMechanicalRepair InformationUpdating RadioFans.CN ELECTRICAL SCHEMATIC DIAGRAMS SCH01_DIGITAL CONNECT SCH02_MAIN

40、 CPU SCH03_EXPANDER SCH04_AUDIO PLD SCH05_DIR DA SUPPLY SCH06_ADI DSP1 SCH07_ADI DSP2 SCH08_ADI DSP3 SCH09_ADI DSP4 SCH10_HDMI SUPPLY SCH11_DECODER SCH12_HDMI SW2 SCH13_HDMI SW1 SCH14_IP OSD SCH15_IP OSD DDR SCH16_VIDEO PLD SCH17_HDMI TX SCH18_E ARC SCH19_NET MODULE CONNECT SCH20_AUDIO/VIDEO CONNECT

41、 SCH21_AUDIO VOLUME SCH22_PREOUT SCH23_VIDEO SELECTOR SCH24_CONNECT SCH25_AMP CONNECT SCH26_ZONEDAC ADC SCH27_MAIN DAC SCH28_FRONT HDMI USB SCH29_SMPS SCH30_232C PHONO SCH31_P.AMP1 SCH32_P.AMP2 SCH33_SPEAKER SCH34_REG SCH35_FLD PRINTED CIRCUIT BOARDS DIGITAL AUDIO VIDEO, FRONT HDMI USB, CONNECT-1, C

42、ONNECT-2, CONNECT-4 DAC, L AMP CONNECT, R AMP CONNECT, FRONT SPEAKER, HEIGHT2 SP, HP, P.SW, CONNECT-3 AMP1, AMP2, SMPS, 232C PHONO, POSISTER, RADIATOR COVER LEVEL DIAGRAM FRONT ch CENTER / SURROUND ch SUBWOOFER ch SURROUND BACK / HEIGHT1 / HEIGHT2 ch ZONE2 / ZONE3 ch BLOCK DIAGRAM ANALOG AUDIO DIAGR

43、AM DIGITAL AUDIO DIAGRAM VIDEO DIAGRAM POWER DIAGRAM SEMICONDUCTORS 1. ICs 2. FL DISPLAY 3. Remote Code Table 9 Caution in servicing ElectricalMechanicalRepair InformationUpdating RadioFans.CN SCHEMATIC DIAGRAMS SCH01_DIGITAL CONNECT All Ref.No. has been described in the parts list are four digits.

44、But there are less than four digits of printed Ref.No. on the PCB, and they have become four digits after the header by adding 0 in the parts list. AUDIO SIGNALTMDS SIGNALANALOG VIDEODIGITAL VIDEOGND LINEPOWER- LINEPOWER+ LINE Confdential DIGITAL_UNIT 8U-310223(1/19) BLM21PG221L6006 BLM21PG221L6002

45、BLM21PG221L6004 BLM21PG221L6005 BLM21PG221L6003 R6014 100 2SC4617EB Q6008 Q6006 KRC402E-RTK KDS160D6002 0.1C6013 R6007 3.3K R6013100K R6006 10K C6010OPEN C6011 OPEN C6009 OPEN C6012 1u R600910K 0.1C6014 KDS160 D6001 R601247K R601010K R6008 OPEN OPEN U6002 R6011 4.7K Q6007 2SA2018 M3.3V DGND SWM3.3V

46、40P-FFC N6004 33P-SOCKET(C125Z2) N6012 33P-SOCKET(C125Z2)N6014 33P-FFC N6010 33P-FFC N6011 OPEN N6002 OPEN N6003 DV5V DV3.3V 19P-FFC N6005 Q6002 KRC402E-RTK BLM21PG221 L6001 C60020.1 Q6003 2SA2018 100K R6004 C6001OPEN Q6005 FDC608PZ 10K R6003 R6002 3.3K C60030.1 Q6004 KRC402E-RTK R6001 10K 0R5075 C6

47、018OPEN 4.7uC6020 0.1C6019 100/6.3C6016 100/6.3C6015 C6017OPEN 4.7uC6022 OPENC6023 0.1C6021 C9116330P BLM21PG221 L9100 R9110 15K C91220.1 C91210.01 C91201000P C910110/6.3 C911710/6.3 R9108 47K C911822/6.3 BLM21PG221 L9104 R9109 0 C91031u SN74AHCU04PWR U1904 R1929 47 SN74AHCU04PWR U1904 SN74AHCU04PWR

48、 U1904 R19271M SN74AHCU04PWR U1904 SN74AHCU04PWR U1904 1.5K R1931 SN74AHCU04PWR U1904 1000P C1939 SN74AHCU04PWR U1904 C1936 0.1 C1937 1000P XCL212B082DR U9201 SWM5V DA+5V VCOM DA3.3V DACGND D5V DGND 7P-EHs N6001 OPENR9217 OPEN.C6024 R6005 OPEN Q6001 HN1K02FU OPENC6004 0R6015 To_8U-210228-6(N5907) CO

49、NNECT-1_UNIT To_8U-210228-2(N5001) DAC_UNIT(1/2) To_8U-210228-1(N9018) A.AUDIO/VIDEO_UNIT(1/4) To_8U-110210-2(N6405) FLD_UNIT To_8U-110207-7(N6513) SMPS_UNIT To_8U-110210-11(N5202) CONNECT-3_UNIT To_8U-110207-8(N3903) 232C/PHONO_UNIT NET_FACT_RST Z2DAC_64fs DLHD Z2DAC_MUTE Z2DAC_256fs Z2DAC_fs Z2DAC_DATA AEXP_OE MIC_DET AEXP_DA_6OUT Z2NETADC_L DIRECT_LED MDAX_LED AEXP_CLK ILLUMI_LED AEXP_STB H/P_DET Z2NETADC_R AVSDA DAC_CCLK TU_SCL TU_INT SEL_CLK FANDET_HIGH MAINADC_RST AVSCL ZONESTB FANDET_ON AMPSIGDET 232I_MO DAC_RST1 ZONECL

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > Denon

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号