1、SERVICE MANUAL Copyright 2013 D&M Holdings Inc. All rights reserved. WARNING: Violators will be prosecuted to the maximum extent possible. Ver.1 S0768-1V01DM/DG1312 Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referri

2、ng to the operating instructions without fail. For purposes of improvement, specifications and design are subject to change without notice. D&M Holdings Inc. MODELJPE3E2EKEAE1E1KE1C MC6000MK2EMPP Professional Digital Mixer and Controller CONTENTS ABOUT THIS MANUAL .3 What you can do with this manual

3、 .3 Using Adobe Reader (Windows version) .4 SAFETY PRECAUTIONS .6 NOTE FOR SCHEMATIC DIAGRAM .7 NOTE FOR PARTS LIST .7 INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNIT .7 TECHNICAL SPECIFICATIONS .9 DIMENSION .10 PRECAUTIONS DURING SERVICE .11 Initializing This Unit .11 DISASSEMBLY .12 SPE

4、CIAL MODE .23 Special mode setting button .23 PROCEDURE AFTER REPLACING THE MICROPROCESSOR, ETC .34 FIRMWARE UPDATE PROCEDURE .34 TROUBLE SHOOTING .43 WAVEFORMS and TROUBLESHOOTING .51 BLOCK DIAGRAM .55 POWER BLOCK DIAGRAM .56 LEVEL DIAGRAM .57 WIRING DIAGRAM .58 PRINTED WIRING BOARDS .59 SCHEMATIC

5、DIAGRAMS (1/5) .63 MAIN UNIT .63 I/O .64 CONTROL 1 .65 CONTROL 2 .66 FRONT .67 EXPLODED VIEW .68 PACKING VIEW .69 SEMICONDUCTORS .70 1. ICs .70 ABOUT THIS MANUAL Read the following information before using the service manual. What you can do with this manual Search for a Ref. No. (phrase) (Ctrl+Shif

6、t+F) You can use the search function in Acrobat Reader to search for a Ref. No. in parts lists. 1.Press Ctrl+Shift+F on the keyboard. The Search window appears. 2.Enter the Ref. No. you want to search for in the Search window, and then click the Search button. A list of search results appears. 3.Cli

7、ck an item on the list. The screen jumps to the page for that item, and the search phrase is displayed. Ctrl Shift F Jump to the target of a schematic diagram connector Click the Ref. No. of the target connector in the red box around a schematic diagram connector. The screen jumps to the target conn

8、ector. Pagemagnificationstaysthesameasbeforethe jump. CP401 CP106 v 3 Using Adobe Reader (Windows version) Properties Click this button and check that the printer is set to a suitable paper size. Page to print Select the following checkbox. More Options : Current View Page Sizing & Handling Select t

9、he following checkbox. Size / Size Options : Fit Add notes to this data (Sign) The Sign function lets you add notes to the data in this manual. Savethefileonceyouhavefinishedaddingnotes. Example using Adobe Reader X On the View menu, click Sign. The Sign pane appears. Example using Adobe Reader 9 On

10、 the Document menu, click Sign. Magnify schematic / printed wiring board diagrams - 1 (Ctrl+Space, mouse operation) Press Ctrl+Space on the keyboard and drag the mouse to select the area you want to view. Theselectedareaismagnified. When you want to move the area shown, hold down Space and drag the

11、mouse. When you want to show a full page view, press Ctrl+0 on the keyboard. CtrlSpace 0 Print a magnified part of the manual The Properties dialog box and functions will vary depending on your printer. 1. Drag the mouse to magnify the part you want to print. 2. On the File menu, click Print. 3. Con

12、figurethefollowingsettingsinthePrintdialogbox. 4. Click the Print button to start printing. 4 Magnify schematic / printed wiring board diagrams - 2 (Pan & Zoom function) The Pan & Zoom function lets you see which part of amagnifieddiagramisbeingshowninaseparate window. Example using Adobe Reader X O

13、n the View menu, point to Zoom, and then click Pan & Zoom. The Pan & Zoom window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Pan & Zoom Window. Magnify schematic / printed wiring board diagrams - 3 (Loupe Tool function) TheLoupeToolfu

14、nctionletsyoumagnifyaspecific part of a diagram in a separate window. Example using Adobe Reader X On the View menu, point to Zoom, and then click Loupe Tool. The Loupe Tool window appears on the screen. Example using Adobe Reader 9 On the Tools menu, point to Select & Zoom, and then click Loupe Too

15、l Window. 5 SAFETY PRECAUTIONS The following items should be checked for continued protection of the customer and the service technician. leakage current check Before returning the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check.

16、 If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. Be sure to test for leakage current with the AC plug in both polarities, in addition, when the sets power is in each state (on, off and stan

17、dby mode), if applicable. CAUTION Please heed the following cautions and instructions during servicing and inspection. Heed the cautions! Cautions which are delicate in particular for servicing are labeled on the cabinets, the parts and the chassis, etc. Be sure to heed these cautions and the cautio

18、ns described in the handling instructions. Cautions concerning electric shock! (1) An AC voltage is impressed on this set, so if you touch internal metal parts when the set is energized, you may get an electric shock. Avoid getting an electric shock, by using an isolating transformer and wearing glo

19、ves when servicing while the set is energized, or by unplugging the power cord when replacing parts, for example. (2) There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Through great care is taken when parts were manufa

20、ctured from sheet metal, there may be burrs on theedgesofparts.Theburrscouldcauseinjuryiffingers are moved across them in some rare cases. Wear gloves to protect your hands. Use only designated parts! Thesetspartshavespecificsafetyproperties(fire resistance, voltage resistance, etc.). Be sure to use

21、 parts which have the same properties for replacement. The burrs have the same properties. In particular, for the important safety parts that are indicated by the z mark on schematic diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they w

22、ere originally placed! For safety seasons, some parts use tapes, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires by arranging them and using clamps to keep them away from heating and h

23、igh voltage parts, so be sure to set everything back as it was originally placed. Make a safety check after servicing! Check that all screws, parts and wires removed or disconnected when servicing have been put back in their original positions, check that no serviced parts have deteriorate the area

24、around. Then make an insulation check on the external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and on the power. Using a 500V i

25、nsulation resistance tester, check that the insulation resistance value between the inplug and the externally exposed metal parts (antenna terminal, headphones terminal,inputterminal,etc.)is1Morgreater.Ifitis less, the set must be inspected and repaired. Many of the electric and the structural parts

26、 used in the set have special safety properties. In most cases these propertiesaredifficulttodistinguishbysight,andtheuse of replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be preserved. Parts with safety propertie

27、s are indicated as shown below on the wiring diagrams and the parts list in this service manual. Be sure to replace them with the parts which have the designated part number. (1) Schematic diagrams .Indicated by the z mark. (2) Parts lists .Indicated by the z mark. The use of parts other than the de

28、signated parts could cause electric shocks,firesorotherdangerous situations. CAUTION Concerning important safety parts 6 NOTE FOR SCHEMATIC DIAGRAM WARNING: Parts indicated by the z mark have critical characteristics. Use ONLY replacement parts recommended by the manufacturer. CAUTION: Before return

29、ing the set to the customer, be sure to carry out either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the set is defective. WARNING: DONO

30、Treturnthesettothecustomerunlesstheproblemisidentifiedandremedied. NOTICE: ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHM ALL CAPACITANCE VALUES ARE EXPRESSED IN MICRO FARAD, UNLESS OTHERWISE INDICATED. P INDICATES MICRO-MICRO FARAD. EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL IN

31、PUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNIT Electrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential difference caused by electrostatic charge during unpacking or repair w

32、ork. 1. Ground for Human Body Besuretowearagroundingband(1M)thatisproperlygroundedtoremoveanystaticelectricitythatmaybecharged on the body. 2. Ground for Workbench Besuretoplaceaconductivesheetorcopperplatewithpropergrounding(1M)ontheworkbenchorothersurface, where the semi-conductors are to be place

33、d. Because the static electricity charge on clothing will not escape through the body grounding band, be careful to avoid contacting semi-conductors with your clothing CBA Grounding Band Conductive Sheet or Copper Plate 1M 1M CBA NOTE FOR PARTS LIST 1. Parts indicated by nsp on this table cannot be

34、supplied. 2. When ordering a part, make a clear distinction between 1 and I (i) to avoid mis-supplying. 3. A part ordered without specifying its part number can not be supplied. 4. Part indicated by mark is not illustrated in the exploded view. WARNING: Parts indicated by the z mark have critical ch

35、aracteristics. Use ONLY replacement parts recommended by the manufacturer. 7 Personal notes: 8 9 TECHNICAL SPECIFICATIONS nAudio(0 dBu=0.775 Vrms, 0 dBV =1 Vrms) PHONO inputs2 Stereo Unbalanced RCA terminal Input impedance:50 k/kohms Level:40 dBV(10 mV) Signal to Noise ratio:Over 82 dB LINE 1, 2 inp

36、uts2 Stereo Unbalanced RCA terminal Input impedance:10 k/kohms Level:0 dBV Signal to Noise ratio:Over 84 dB LINE 3, 4 inputs2 Stereo Unbalanced RCA terminal Input impedance:10 k/kohms Level:0 dBV Signal to Noise ratio:82 dB or later Equalizer (CH)3 Band Channel EQ Adjustment Range: HI (High Range) :

37、 , 90 dB +10 dB MID (Medium Range) : , 90 dB +10 dB LOW (Low Range) : , 90 dB +6 dB MIC inputs 2 Monaural MIC 1:Combo jack (terminal for balanced XLR and balanced 1/4 inch TRS) (1: ground, 2: hot, 3: cold, chip: hot, ring: cold, sleeve: ground) MIC 2:Balanced 1/4 inch TRS terminal Input impedance:5

38、k/kohms Level:60 dBu 16 dBu Equalizer (MIC)3 Band Adjustment Range: HI (High Range) : 15 +15 dB MID (Medium Range) : 15 +15 dB LOW (Low Range) : 15 +15dB USB audio inputs2 Stereo (4 Monaural) 16 bit, Fs : 44.1 kHz USB B MASTER output Balanced:Stereo, balanced XLR terminal (1: Ground, 2: Hot, 3: Cold

39、) DA converter:24 bit Load impedance:Over 600 /ohms Level:+ 4 dBu (Max + 24 dBu) When RL=100 k/kohms Frequency response:20 Hz 20 kHz (1 dB) THD:Less than 0.05% Crosstalk:Less than 90 dB (1 kHz) Unbalanced:Stereo RCA terminal Load impedance:100 k/kohms Level:0 dBu (Max + 20dBu) BOOTH Output Stereo ba

40、lanced 1/4 inch TRS terminal Load impedance:Over 600 /ohms Level:+ 4 dBu (Max + 24 dBu) When RL=100 k/kohms Headphone outputStereo Load impedance:40 /ohms Level:100 mW USB audio output2 Stereo (4 Monaural) 16 bit, 44.1 kHz USB B nGeneral USB MIDI I/O:IN: 1ch, OUT: 1ch MIDI 1.0, MIDI Clock USB B CH/M

41、ASTER Meter: PPM 7 Point LED 20 +10 dB, Peak CH Fader: 45 mm Slim Type Fader Cross Fader: 45 mm Fader Power voltage:DC12V (the unit) AC adapter input: U.S.A. and Canada models:AC 120 V, 60 Hz European,U.K. and Asia/ Pacific models:AC 230 V, 50 Hz AC adapter output:DC 12V 3A Power consumption:24 W Op

42、erating temperature:+5 C +35 C Operating humidity:25 % 85 % Storage temperature:20 C 60 C For the purpose of improvement, the specifications and design are subject to change without notice. 10 DIMENSION Unit : in. (mm) 18 11/32 (460.0) 7/16 (11.0) 27/32 (21.5) 1 57/64 (48.0) 10 3/64 (255.0) 45/64 (17.7) 5/64 (2.0) Weight : 9 lbs 8 oz (4.3 kg) 11 Initializing This Unit Initialize this unit if you have replaced the microprocessor, one of the parts around the microprocessor, or the main PWB. 1. Turn on the power while pressing the BACK, FWD and X-F LINK buttons simultaneously. 2. Return to def