《Denon-TU604CI-tun-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《Denon-TU604CI-tun-sm维修电路图 手册.pdf(73页珍藏版)》请在收音机爱好者资料库上搜索。
1、Denon Brand Company, D&M Holdings lnc. e Ver. 1 SERVICE MANUAL AM-FM / XM MULTIPLE TUNER MODELJPE3E2EKE2AE1CE1KEUT TU-604CI ? For purposes of improvement, specifications and design are subject to change without notice. Please use this service manual with referring to the operating instructions witho
2、ut fail. Some illustrations using in this service manual are slightly different from the actual set. 注意 前、 必読。本機、火災、感電、 対安全性確保、 配慮、法的電気用品安 全法、所定許可得製造 。従際、 安全性維持、 記載注意事項必守。 本機仕様性能改良、予告変更 。 補修用性能部品保有期間、製造打切後 8 年。 修理際、必取扱説明書参照上、作業行 。 本文中使用、説明都合上現物 多少異場合。 X0369 V.01 DE/CDM 0805 RadioFans.CN 2 TU-604CI P
3、lease heed the points listed below during servicing and inspection. Heed the cautions! Spots requiring particular attention when servicing, such as the cabinet, parts, chassis, etc., have cautions indicated on labels or seals. Be sure to heed these cautions and the cautions indicated in the handling
4、 instructions. Caution concerning electric shock! (1) An AC voltage is impressed on this set, so touching in- ternal metal parts when the set is energized could cause electric shock. Take care to avoid electric shock, by for example using an isolating transformer and gloves when servicing while the
5、set is energized, un- plugging the power cord when replacing parts, etc. (2)There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Though great care is taken when manufacturing parts from sheet metal, there may in some rare
6、 cases be burrs on the edges of parts which could cause injury if fingers are moved across them. Use gloves to protect your hands. Only use designated parts! The sets parts have specific safety properties (fire resis- tance, voltage resistance, etc.). For replacement parts, be sure to use parts whic
7、h have the same properties. In par- ticular, for the important safety parts that are marked z on wiring diagrams and parts lists, be sure to use the desig- nated parts. Be sure to mount parts and arrange the wires as they were originally! For safety reasons, some parts use tape, tubes or other in- s
8、ulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires inside and clamps are used to keep wires away from heating and high voltage parts, so be sure to set everything back as it was originally. Inspect for saf
9、ety after servicing! Check that all screws, parts and wires removed or discon- nected for servicing have been put back in their original po- sitions, inspect that no parts around the area that has been serviced have been negatively affected, conduct an insu- lation check on the external metal connec
10、tors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and turn the power switch on. Us- ing a 500V insulation resistance tester, check that the in- sula
11、tion resistance between the terminals of the power plug and the externally exposed metal parts (antenna ter- minal, headphones terminal, microphone terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Concerning important safety parts Many of the e
12、lectric and structural parts used in the set have special safety properties. In most cases these prop- erties are difficult to distinguish by sight, and using re- placement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be pr
13、eserved. Parts with safety properties are indicated as shown below on the wiring dia- grams and parts lists is this service manual. Be sure to re- place them with parts with the designated part number. (1) Schematic diagrams . Indicated by the z mark. (2) Parts lists . Indicated by the z mark. Using
14、 parts other than the designated parts could result in electric shock, fires or other dangerous situations. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Before returning the unit to the customer,
15、 make sure you make either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective. CAUTION CAUTION RadioFans.CN 3 TU-604CI 、点
16、検時注意願。 注意事項守! 特注意必要個所 、 部品、 捺印注意 事項表示。 注意書取扱説明 書注意事項必守。 感電注意! (1) 、交流電圧印加通電 時内部金属部触感電。 従通電時、絶縁使用手 袋着用、部品交換、電源抜 感電注意。 (2) 内部高電圧部分、通電時取扱 十分注意。 分解、組立作業時注意! 板金部品端面、部品製造時充分管理 、 板金端面鋭利箇所有 、 部品端面触指動怪我 場合十分注意作業下。 手 保護手袋着用。 指定部品使用! 部品難燃性耐電圧安全上特性持 。 従交換部品、 使用 同特性部品使用。特配線 図、部品表 z 印指定安全上重要部品 必指定使用。 部品取付配線引、 元!
17、安全上、絶縁材料使用、 基板浮取付部品。 内部配線引発熱部品 高圧部品接近配慮、 必元。 後安全点検! 取外、 部品、 配線元 、 個所周辺劣化 点検、 外部金属端 子部、 電源刃間絶縁 、安全性確保確認。 (絶縁方法) 電源電源抜、 外、電源入。500V 絶縁抵抗計 用、 電源端子外部露出金属部 端子、端子、端子、入力端子 間、絶縁抵抗値 M 以上 確認。 値以下点検修理 必要。 安全上重要部品 本機使用多電気部品、 機構部品安 全上、 特別特性持。 特性 場合、 外観判別、 部品高 定格(定格電力、耐圧)持使用安全性 維持、 限。 安全上特性持部 品、 配線図、 部品表 表示必指定部品番号
18、 使用願。 (1) 配線図 z 表示。 (2) 部品表 z 表示。 指定部品異使用場 合、感電、火災危険生恐 。 注意 注意 RadioFans.CN 4 TU-604CI DIMENSION RadioFans.CN 5 TU-604CI 整形図 調整部品交換等、類結束 移動場合、作業完了時点 整形。正整形 発生原因。 上面整形 WIRE ARRANGEMENT If wire bundles are untied or moved to perform adjustment or parts replacement etc., be sure to rearrange them neatl
19、y as they were originally bundled or placed afterward. Otherwise, incorrect arrangement can be a cause of noise generation. Wire arrangement viewed from the top Back Panel side Front Panel side RadioFans.CN 6 TU-604CI 時注意事項 初期化 周辺部品、Digital 基板等交換場 合、初期化。 1.ON/STANDBY 押、起動状態。 2.MODE TUNER 3 同時押 、SELE
20、CT/ENTER 3 秒以上押。 3.表示約 1 秒間隔点滅確認後、 2 指離。 初期化。 注意 :上記 3 状態場合、一度操作 1 直。 初期化行客様設定内容工場出 荷状態戻、設定内容 控初期化後再設定。 Option board 修理対象外製品。 対応製品交換。 ACD-AMFM ACD-XMSIR ACD-HD ACD-DAB CAUTION IN SERVICING Initializing MULTI TUNER MULTI TUNER initialization should be performed when the com and peripheral parts of co
21、m, and Digital P.W.B. are re- placed. 1. Press the “ON/STANDBY” button, starting state it does. 2. Press the “SELECT/ENTER” button and hold it in for at least 3 seconds, while simultaneously pressing the “MODE” button and the “TUNER 3” button. 3. Check that the entire display is flashing with an int
22、erval of about 1 second, and release your fingers from the 2 but- tons. The microprocessor will be initialized. Note:If step 3 does not work, start over from step 1. All user settings will be lost and this factory setting will be recovered when this initialization mode. So make sure to m+emorize you
23、r setting for re- storing after the initialization. ON / STANDBYSELECT / ENTERMODETUNER 3 The parts of Option board are not serviceable. Please replace the product itself. ACD-AMFM ACD-XMSIR ACD-HD ACD-DAB RadioFans.CN 7 TU-604CI DISASSEMBLY Disassemble in order of the arrow of the figure of followi
24、ng flow. 下記図矢印順番。 In the case of the re-assembling, assemble it in order of the reverse of the following flow. 再組立場合、下記逆順番組立 In the case of the re-assembling, observe attention of assembling it. 再組立場合、 組立注意遵守。 CABINET TOP PANEL FRONT SUB ASSYCHASSIS BACK SUB ASSY Refer to DISASSEMBLYRefer to DISASSE
25、MBLY 1.PANEL FRONT SUB ASSY 4.CHASSIS BACK SUB ASSY and EXPLODED VIEWand EXPLODED VIEW POWERON UNIT AMFM BUILT-IN P.W.B UNIT ASSY (Ref. No. of EXPLODED VIEW : 7) (Ref. No. of EXPLODED VIEW : 42) FRONT P.W.B UNIT (Ref. No. of EXPLODED VIEW : 10) HEAT SINK MAIN L SUB ASSYSTBY UNIT ASSYIO OPTION UNIT /
26、 Refer to DISASSEMBLYRefer to DISASSEMBLYIO BUILT-IN UNIT / 2.HEAT SINK MAIN L SUB ASSY7.STBY UNIT ASSYETHERNET P.W.B UNIT ASSY and EXPLODED VIEWand EXPLODED VIEWRefer to DISASSEMBLY POWER2 UNIT STBY1 UNIT5.IO OPTION UNIT / (Ref. No. of EXPLODED VIEW : 16) (Ref. No. of EXPLODED VIEW : 33)IO BUILT-IN
27、 UNIT / POWER3 UNIT STBY2 UNITETHERNET P.W.B UNIT ASSY (Ref. No. of EXPLODED VIEW : 17) (Ref. No. of EXPLODED VIEW : 34)and EXPLODED VIEW IO OPTION UNIT (Ref. No. of EXPLODED VIEW : 35) HEAT SINK MAIN R SUB ASSYTRANS IO BUILT-IN UNIT Refer to DISASSEMBLYRefer to DISASSEMBLY (Ref. No. of EXPLODED VIE
28、W : 36) 3.HEAT SINK MAIN R SUB ASSY8.TRANS ETHERNET P.W.B UNIT ASSY and EXPLODED VIEWand EXPLODED VIEW (Ref. No. of EXPLODED VIEW : 37) POWER1 UNIT TRANS (Ref. No. of EXPLODED VIEW : 15) (Ref. No. of EXPLODED VIEW : 28) XMBUS UNIT (Ref. No. of EXPLODED VIEW : 18)MAIN P.W.B UNIT ASSY Refer to DISASSE
29、MBLY 6.MAIN P.W.B UNIT ASSY and EXPLODED VIEW MAIN P.W.B UNIT ASSY (Ref. No. of EXPLODED VIEW : 30) Front side Picture B Picture E Picture A Picture C Picture D Picture G Picture F Top view The viewpoint of each photograph (photography direction) 各図視点(撮影方向) RadioFans.CN 8 TU-604CI 1. PANEL FRONT SUB
30、 ASSY (1) Remove the screws.(。 ) (2) Disconnect the connector wires and remove the screw.(。 ) Please refer to EXPLODED VIEW for the disassembly method of each P.W.B included in PANEL FRONT SUB ASSY . PANEL FRONT SUB ASSY 各基板 EXPLODED VIEW 参照。 proceeding ( 手順 ) : CABINET TOP PANEL FRONT SUB ASSY Bott
31、om view CORD HOLDER : Loose CP1003CP1001 Picture F CORD HOLDER : Loose CP1102 FFC CABLE Picture C cut RadioFans.CN 9 TU-604CI 2. HEAT SINK MAIN L SUB ASSY (1) Disconnect the connector wires. (。 ) (2) Disconnect the connector wires and remove the screws.(。 ) proceeding ( 手順 ) : CABINET TOP PANEL FRON
32、T SUB ASSY HEAT SINK MAIN L SUB ASSY (A) Picture A HEAT SINK MAIN R SUB ASSY HEAT SINK MAIN L SUB ASSY CP302CN303CN302CP301CP305 CP304CP303 Picture A Detail : (A) CP307CP306 Top view (B) HEAT SINK MAIN L SUB ASSY RadioFans.CN 10 TU-604CI (3) Disconnect the connector wires.(。 ) Please refer to EXPLOD
33、ED VIEW for the disassembly method of each P.W.B included in HEAT SINK MAIN L SUB ASSY . HEAT SINK MAIN L SUB ASSY 各基板 EXPLODED VIEW 参照。 3. HEAT SINK MAIN R SUB ASSY (1) Disconnect the connector wires.(。 ) (2) Disconnect the connector wires and remove the screws.(。 ) Please refer to EXPLODED VIEW fo
34、r the disassembly method of each P.W.B included in HEAT SINK MAIN R SUB ASSY . HEAT SINK MAIN R SUB ASSY 各基板 EXPLODED VIEW 参照。 Picture D Detail : (B) CP118CN311CP308 proceeding ( 手順 ) : CABINET TOP PANEL FRONT SUB ASSY HEAT SINK MAIN L SUB ASSY HEAT SINK MAIN R SUB ASSY CP309CP119 CN304CN305CN307CN3
35、08 Picture D HEAT SINK MAIN R SUB ASSY CP309CP119 Top view HEAT SINK MAIN R SUB ASSY RadioFans.CN 11 TU-604CI 4. CHASSIS BACK SUB ASSY (1) Remove the P.W.B HOLDER and disconnect the connector wire.(P.W.B 。 ) proceeding ( 手順 ) : CABINET TOP CHASSIS BACK SUB ASSY CHASSIS BACK SUB ASSY AMFM BUILT-IN P.
36、W.B UNIT ASSY Top view P.W.B HOLDER CP1102 Picture C ETHERNET P.W.B UNIT ASSY AMFM BUILT-IN P.W.B UNIT ASSY RadioFans.CN 12 TU-604CI (2) Disconnect the connect wires.(。 ) (3) Remove the screws.(。 ) Please refer to EXPLODED VIEW for the disassembly method of each P.W.B included in CHASSIS BACK SUB AS
37、SY . CHASSIS BACK SUB ASSY 各基板 EXPLODED VIEW 参照。 CN401CP602 CN402CP603 (A) Picture A CP456 cut Top view Detail : (A) ? Picture B RadioFans.CN 13 TU-604CI 5. IO OPTION UNIT / IO BUILT-IN UNIT / ETHERNET P.W.B UNIT ASSY (1) Remove the IO OPTION UNIT , IO BUILT-IN UNIT and ETHERNET UNIT. (IO OPTION UNI
38、T IO BUILT-IN UNIT ETHERNET UNIT 。 ) 6. MAIN P.W.B UNIT ASSY Please refer to EXPLODED VIEW for the disassembly method of MAIN P.W.B UNIT ASSY. MAIN P.W.B UNIT ASSY EXPLODED VIEW 参照。 7. STBY UNIT ASSY (1) Disconnect the connector wires and FFC Cables.( FFC 。 ) Please refer to EXPLODED VIEW for the di
39、sassembly method of each P.W.B included in STBY UNIT ASSY. STBY UNIT ASSY 各基板 EXPLODED VIEW 参照。 proceeding ( 手順 ) : CABINET TOP CHASSIS BACK SUB ASSY IO OPTION UNIT / IO BUILT-IN UNIT / ETHERNET P.W.B UNIT ASSY CP405 Picture B CP1101 CP404CP407 IO OPTION UNITETHERNET P.W.B UNIT ASSY IO BUILT-IN UNIT
40、 proceeding ( 手順 ) : CABINET TOP CHASSIS BACK SUB ASSY IO OPTION UNIT / IO BUILT-IN UNIT / ETHERNET P.W.B UNIT ASSY MAIN P.W.B UNIT ASSY proceeding ( 手順 ) : CABINET TOP CHASSIS BACK SUB ASSY STBY UNIT ASSY Picture B STBY2 UNIT STBY1 UNIT MAIN P.W.B UNIT ASSY RadioFans.CN 14 TU-604CI 8. TRANS (1) Rem
41、ove the PANEL FRONT ASSY.(PANEL FRONT ASSY 。 ) (2) Disconnect the connector wires.(。 ) (3) Disconnect the connector wires and remove the screws.(。 ) proceeding ( 手順 ) : CABINET TOP PANEL FRONT SUB ASSY TRANS Picture A cut CP305CP301 CP303CP304 Picture B cut CP453 RadioFans.CN 15 TU-604CI 方法 1. 動作仕様
42、起動状態下記条件該当場合、 情報表示。 起動方法 ( 表示 ): MODE TUNER 1 同時押 、SELECT/ENTER 3 秒以上押。 後、SELECT/ENTER JOG 右内容 FL Display 表示。 2. 表示順序 仕向地表示 情報 情報 情報 CHECK WITH TEST MODE 1. Operation Spec When the following conditions are satisfied at its starting state, error information is displayed. Starting method (com version
43、display mode): Press the “SELECT/ENTER” button and hold it in for at least 3 seconds, while simultaneously pressing the “MODE” button and the “TUNER 1” button. Then, “SELECT/ENTER” JOG is turned clockwise and the following information is displayed on FL Display. 2. Display Order Destination informat
44、ion Main-com version information Sub-com version information Ethernet information SELECT / ENTERMODETUNER 1 RadioFans.CN 16 TU-604CI -MEMO- RadioFans.CN 17 TU-604CI TROUBLE SHOOTING 1. POWER 1.1. Power not turn on 1.2. Fuse is blown Power not turn on YES Is the fuse blown? NO Refer to Fuse is blown.
45、 YES Are there any incomplete connections in the connectors connecting between the various circuit boards? NOCheck for damage of the circuitry parts and replace any defective parts. YES YESConnect the connectors properly. Is DC3.3V voltage supplied to the com? NO Is a DC3.3V voltage output when the
46、cord supplying the power to the com is unplugged? NOCheck the parts from com to the primary circuitry and replace any defective parts. YESYES Check the com periphery circuitry and replace any defective parts. Check the circuitry and parts the com for damage and short-circuits, and replace any defect
47、ive parts. Fuse is blown YESYESYES Check for leaks or short circuits in the pri- mary side parts, and replace any defec- tive parts. Check for short circuits in the rectifier diodes and circuitry of the secondary side rectifying circuits, and replace any defec- tive parts. Check for short circuits i
48、n the power stabi- lizer units regulator output terminal and the ground, and replace any defective parts. YESYESYES After repairing, also replace the fuse. 1. 電源 1.1. 電源入 1.2. 断線 電源入 YES 断線? NO断線参照 。 YES各基板間接続不 完全接続部分? NO回路部品破損確認、不良部品 交換。 YES YES 正接続。 DC3.3V 供給 ? NO電源供給 抜 DC3.3V 出力? NO 1 次回路部品確認、 不良
49、部品交換。 YESYES 周辺回路確認、不良部品 交換。 電源回路部品破 損短絡確認、不良部品交換 。 断線 YESYESYES 1 次側部品短絡確認 、不良部品交換。 2 次側整流回路、整流 回路短絡確認、不良 部品交換。 電源安定化部出力端子 GND 短絡確認、短絡場 合、不良部品交換。 YESYESYES 修理後、FUSE 交換。 RadioFans.CN 18 TU-604CI BLOCK DIAGRAM RadioFans.CN 19 TU-604CI SEMICONDUCTORS Only major semiconductors are shown, general semiconductors etc. are omitted to list. 主半導体記載。汎用半導体記載省略。 1. ICs M30626FJPFP (IC103) M30626FJPFP Terminal Function Pin Pin