JBL Technical Note - Vol.1, No.23 电路原理图.pdf

上传人:cc518 文档编号:113022 上传时间:2020-11-20 格式:PDF 页数:8 大小:561.52KB
下载 相关 举报
JBL Technical Note - Vol.1, No.23 电路原理图.pdf_第1页
第1页 / 共8页
JBL Technical Note - Vol.1, No.23 电路原理图.pdf_第2页
第2页 / 共8页
JBL Technical Note - Vol.1, No.23 电路原理图.pdf_第3页
第3页 / 共8页
亲,该文档总共8页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《JBL Technical Note - Vol.1, No.23 电路原理图.pdf》由会员分享,可在线阅读,更多相关《JBL Technical Note - Vol.1, No.23 电路原理图.pdf(8页珍藏版)》请在收音机爱好者资料库上搜索。

1、Technical Notes Volume 1, Number 23 JBLs HLA Series Loudspeaker Systems and DCD Transducers Introduction: HLA stands for horn loaded array and is JBLs name for a revolutionary new series of loudspeaker systems intended for the highest quality tour sound applica- tions. DCD stands for dual coil drive

2、 and refers to a completely new magnet/voice coil topology for cone transducers that results in more efficient use of both steel and magnetic material, enabling us to reduce the transducer weight to about one-third that of traditional designs. Other characteristics of these transducers are their hig

3、h linearity, excellent heat dissipation, and adaptability to driving horn loads. The basic HLA system is a three-way horn loaded array that makes good use of the light-weight trans- ducers developed for it. Arrayability is the key word.These components are mounted in an aluminum SpaceFrame, and thro

4、ugh an ingenious system of Figure 1. HLA array for medium size venue (flat front) interlocking parts, the MultiBand Waveguide can be tilted up or down as required without the need for altering the basic rigging. It is the small size and weight of the transducers that makes this possible. A unique du

5、al 460-mm (18 in) subwoofer system com- plements the 3-way horn array. In this Technical Note we will discuss the new trans- ducer topology in detail inasmuch as it is central to the HLA system design. We will then present details and performance data on the total system. Basic System Concept: We wi

6、ll begin with an overview of the basic system concept. Figure 1 shows a typical array for a medium size venue with the systems adjusted for 40 horizon- tal and 45 vertical coverage. Note that the basic 3- way horn/waveguide assembly in the model 4895 can Figure 2. HLA array for medium size venue (cu

7、rved front) be tilted 15 as a unit while the SpaceFrame remains fixed. For wider coverage the two vertical stacks may be splayed outward as shown in Figure 2. The goal is to use a minimum number of high intensity, highly directive sources so that each listener hears a mini- mum number of effective s

8、ources, with a resultant high direct-to-reverberant ratio. The model 4897 subwoofer part of the system is not horn loaded and makes use of two 460 mm (18 in) diameter cone transducers in an optimized enclosure. The MultiBand Waveguide with attached magazine is clearly seen in Figures 1 and 2. All th

9、ree horn sec- tions are of Optimized Aperture design. The high-fre- quency horn (shown at the top of the middle module) is driven by the model 2451SL, which was discussed in detail in Technical Note Volume 1, Numbers 21. This portion of the system covers the frequency range from 1140 Hz to 16 kHz. T

10、he lower and upper-midrange parts of the spec- trum are covered by waveguides that span the fre- quency ranges from 100 to 280 Hz and 280 Hz to 1140 Hz. As a group, the three horns comprise a MultiBand Waveguide. Key elements in the perfor- mance of the two midrange horns are the new cone transducer

11、s designed specifically for horn application. These are known as DCD, Direct Cooled, Differential Drive transducers, and we will now describe them in detail. The DCD Transducers: Anatomy of a DCD transducer: Figure 3 shows a section view of a standard JBL magnet-voice coil assembly at the left and a

12、n equiva- lent DCD version of it at the right. We use the term equivalent in that this comparison of both motors will have the same electrical-to-mechanical power cou- pling coefficient, (Bf/RE, and also the same moving mass. We are analyzing the two structures in paral- lel, so to speak, in order t

13、o clarify the differences between them. In the standard design, magnetic flux B crosses the gap in which a coil of wire of length / is placed. The Figure 3. Comparison of standard and DCD technology coil has an electrical resistance, RE. These quantities establish the value of (Bf/RE. Next, we move

14、to the DCD topology, as shown at the right in Figure 3. In this design there are two mag- netic gaps that have opposite flux. Two voice coils are used, and they are connected in reverse so that the mechanical forces they produce will add (be in phase). For the moving mass to remain the same, the voi

15、ce coil winding must have the same height and half the width as in the standard case. The value of B will be kept the same. When these changes are made, the total length (I) of the voice coil will be doubled and the resistance per-unit length of wire will be doubled, since the cross- sectional area

16、has been halved. The total resistance of both voice coils in series will then be four times what it was in the standard case. Since (Bf will have quadrupled (remember that I has doubled), the new value of (Bif/RE will be (B2f/4RE. This is equal to 4(Blf/4RE, which of course reduces directly to (Bf/R

17、E. In terms of electrical-to-mechanical coupling the two approaches are identical; but in other areas we have gained a great deal: 1. The new voice coil assembly now has twice the surface area of the old one. This means that it will have twice the heat dissipation of the old coil, which translates d

18、irectly into twice the power input capability for a given operating temperature and observed amount of dynamic compression. 2. The new voice coil structure will have less effec- tive inductance than the standard one, since the reversely wound coils will have negative mutual induc- tance between them

19、. This translates into a flatter impedance curve at higher frequencies, producing more acoustical output for a given drive signal. 3. The compact nature of the DCD magnet structure requires much less iron in the magnetic return path. As a result, a DCD transducer can weigh as little as one-third the

20、 equivalent standard design. This advan- tage shows up primarily in overall system weight and ease of installation and adjustment. Other design features in the DCD transducers include: 1. The small overall magnet structure can be conve- niently nested in a large heat sink for efficient dissipa- tion

21、 of heat from the coils, as can be seen in Figure 4. 2. The heatsink fins protrude outside the magazine in which the transducers are mounted. The fins are shaped in such a way that they provide optimum cool- ing via airflow through the heatsinks. In addition, the lower-midrange driver has vented gap

22、 cooling. Transducer linearity: The neodymium magnet material used in the DCD transducers is much less prone to flux modulation 2 Standard Magnetic structure DCD Magnetic structure % is four times greater than in standard design; / is two times longer than in standard design f? and / Figure 4. Secti

23、on view of JBL 2251H transducer than ferrite materials. As a result, the flux shorting ring, an essential part of JBLs Symmetrical Field Geometry, is not necessary with neodymium struc- tures. Figure 5 shows the second quadrant perfor- mance of the B-H curves for typical neodymium and ferrite magnet

24、 materials. We can see that a typical operating point for the neodymium magnet is much higher along the B-axis than that of a ferrite magnet. Therefore, for a given change in magnetizing force produced by signal current in the voice coil, the result- ing change in induced flux (AB/BJ will be fairly

25、small. By contrast, the resulting change in induced flux for the ferrite magnet will be AB/B,. Since B, is less than B, the total variation in induced flux will be greater with the ferrite magnet. There is about a three-to-one ratio between the amount of flux modulation of the two magnet materials,

26、corresponding to an approximate 10 dB advantage for neodymium over ferrite at any operating level. Figure 5. Flux modulation in ferrite and neodymium magnet structures Figure 6 shows the on-axis response and 2nd and 3rd harmonic distortion for the 4895 three-way wave- guide array. The nominal power

27、input to the lower and upper-midrange sections is 10 watts, while the match- ing power required for the HF section would be about 1 watt, due to the higher sensitivity of the HF section. This corresponds to a 1 watt, 1 meter output of 116 dB. Note that the 2nd harmonic distortion in the range from 3

28、00 Hz to about 1 kHz is well below 1 %, rising to about 3% in the range above about 1600 Hz. Third harmonic distortion is well below 1% throughout the range. Figure 6. HLA 4895, distortion at 10 watts (dashed curve 2nd harmonic; dotted curve 3rd harmonic) Finally, we want to point out the extremely

29、flat on- axis response of the 4895 system. This illustrates the inherent linearity and smooth response of the MultiBand Waveguide, augmented by the capability of the JBL DSC 280 controller in fine-tuning and time aligning of complex systems. Driver optimization for LF horn application: Our founder,

30、James B. Lansing, knew the impor- tance of light weight moving systems and high magnet strength in designing cone transducers for the large theater horn systems he develop during the thirties and forties. Many years later, Keele (1977) analyzed the application of cone transducers with bass horns and

31、 arrived at the graphical data shown in Figure 7. Keele Thiele-Small parameters to define the useful range of the transducer as a low frequency horn dri- ver. The range of flat power response for a cone trans- figure 7. Keeles data on driver parameters for LF horn application Log frequency (Hz) MAGN

32、ITUDE (dB) + B (gauss) AB/Bn AB/Bf - H (oersteds) 6dB/octave 6dB/octave nr.mm Relative response (dB) 3 ducer in this application generally extends up to fHM, which is given by: Generally, low frequency performance of the dri- ver/horn is basically dependent on horn parameters. High frequency respons

33、e is driver related, and the pri- mary roll-off is caused by the drivers mass breakpoint, fHM. The mass breakpoint for the 2254 355 mm (14 in) DCD transducer is 560 Hz, an octave above the 280 Hz upper crossover frequency. As we move higher in frequency, the mass break- points cannot always extend t

34、o the limit of the intend- ed bandpass. The mass breakpoint for the JBL 2251 250 mm (10 in)DCD transducer is calculated to be 610 Hz, about an octave below the intended crossover fre- quency of 1200 Hz. However, the crossover frequency between the upper-midrange and HF portions of the HLA system is

35、1140 Hz, so the natural rolloff of the dri- ver adds directly to the electrical rolloff in the dividing network (see Figure 15) to achieve the ideal value at crossover. With HF compression drivers, as noted in JBL Technical Notes Volume 1, Numbers 8 and 11, the mass breakpoint, which is normally in

36、the 3500 Hz range, may be one-third to one-fourth of the desired upper frequency limit, thus requiring up to 9 or 12 dB of electrical equalization at high frequencies in order to maintain flat power response. Keele shows an additional inflection point, fHL, which is caused by voice coil inductance a

37、nd is given by: In the case of the upper mid-frequency DCD model 2251 ,which is already performing up to an octave above its mass breakpoint, we wanted to minimize the effects of any amount, however small, of voice coil inductance. A drawn copper sleeve was placed over the pole tip magnet assembly.

38、Acting like a shorted secondary turn in a transformer, it effectively swamps out the effect of voice coil inductance, making the high frequency impedance of the transducer virtually resis- tive. The result is extended HF performance approaching the theoretical limit. Performance of the Subwoofer Sys

39、tem: The model 4897 subwoofer uses two model 2242H SVG transducers in an enclosure made of a trape- zoidal tubular frame integrated with a carbon fiber/honeycomb composite material. The result of this is an increase in rigidity and a significant reduction in weight. The porting of the LF system is b

40、y way of a large area aperture, contoured at each end, that virtu- ally eliminates turbulence at the highest drive levels, allowing the LF system to deliver full output at enclo- sure resonance with minimum port compression. Since vent and enclosure losses have been signifi- cantly reduced, the syst

41、em Q has been raised an order of magnitude, resulting in about 3 dB more out- put than the same pair of transducers exhibit in a con- ventional enclosure. The data shown in Figure 8 indi- cates the improvement in LF headroom produced by the reduction in port turbulence. In this figure, port out- put

42、 level at 25 Hz is plotted as a function of relative input power level using standard porting as well as the radiused porting afforded by the Linear Dynamics Aperture vent design. Note that there is an 8-dB Figure 8. Port Compression: Linear Dynamics Aperture versus standard porting. fHM = 2VQB fHL

43、= RE/TCU Gain, dB 8dB Radiused 25Hz straight 25Hz i Power added , dB 4 improvement in output level over standard porting at the point where both porting systems exhibit 2 dB of compression. The 1-watt, 1-meter output and impedance modulus of the LF system are shown in Figure 9, and the one- tenth po

44、wer (160 watts) output and distortion (second and third harmonics raised 20 dB) are shown in Figure 10. When used in multiples, the effective LF alignment of the ensemble will change, producing a 3-dB rise in very low frequency relative response with each dou- bling of units. Directional Performance

45、 of the HLA System: The data shown in Figures 11, 12, and 13 show respectively the -6-dB beamwidth, directivity index(DI) and Q, and the off-axis response of the 4895 system. The horizontal beamwidth narrows uniformly from 125 Hz to 10 kHz. The vertical beamwidth shows only slight inflections in the

46、 vicinity of the crossover fre- quencies, but is otherwise quite uniform in its pattern narrowing over the same frequency range. The hori- zontal coverage is 40 from 1 to 16 kHz, while the ver- tical coverage is 30 over the same frequency range. This indicates that coverage of multiple units, splaye

47、d both horizontally and vertically will be uniform. The DSC 280 Digital Controller: The JBL DSC 280 digital controller is an integral element in the HLA system concept. Multiple system files are stored in the DSC 280, which take into account the number of array elements and the interac- tion among t

48、hem at long wavelengths. As an example of the degree of control, Figure 14 shows the electrical drive curves for a 2x1 array configuration. Individual acoustical contributions of the three sections of the waveguide are shown in Figure 15, and overall acoustical amplitude and phase response of the sy

49、s- tem is shown in Figure 16. References: 1. J. Eargle and W. Gelow, Performance of Horn Systems, Low-Frequency Cut-off, Pattern Control, and Distortion Trade-offs, presented at the Audio Engineering Society Convention, Low Angeles, November 1996; preprint number 4330. 2. M. Gander and J. Eargle, Measurement and Estimation of Large Loudspeaker Array Performance, J. Audio Engineering Society, volume 38, number 4 (1990). 3. D. B. Keele, Low Frequency Horn Design Using Thiele-Small Driver Parameters, presente

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > JBL

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号