1、Technical Notes Volume 3, Number 2: JBLs New LSR Mid-Field Monitors 1. Introduction and Basic System Description: As the digital recording community con- templates higher sampling rates and greater resolution and more playback channels the need for continuing refinement in all aspects of monitoring

2、takes on high priority at JBL. LSR stands for Linear Spatial Reference, and it represents a change in the way we have traditionally measured and qualified monitor frequency response. Essentially, we have defined a nominal listening zone that is 30 horizontally and 15 vertically, and we have worked t

3、o make the response extremely flat within that entire solid angle, instead of limiting the design criteria to the more conventional approach of optimizing response along the primary (zero degree) axis.The need for this approach arises in the new era of surround sound mixing, where we expect there to

4、 be an accurate listening zone that will accommodate several important auditors: engineer, producer, and of course arranger/musician. JBLs first product embodying these design principles is the mid-field LSR32, a three-way system consist- ing of a 300 mm (12 in) LF transducer, a new 125 mm (5 in) MF

5、 transducer, and a new damped titanium 25 mm (1 in) dome HF transducer. In order to achieve the degree of response smoothness necessary in this program, we had to pay closer attention than usual to details of transition frequency and slope, as well as transducer placement. For example, the LSR32 has

6、 its MF and HF transducers mounted on a rotatable sub-baffle so that their desired optimum orientation can be maintained for either vertical or horizontal positioning of the LF enclosure. Two other aspects of monitor design have received added attention: reduction of distor- tion (by nearly an order

7、 of magnitude) and control of enclosure resonances (the entire baffle is a composite carbon fiber material that reduces resonances to a very low level). The quest for lower distortion meant changes in diaphragm materials as well as fundamental changes in magnet/motor topol- ogy. JBLs Differential Dr

8、iveTMtechnology, developed earlier for certain high-level music reinforcement applications, has been adapted to high-performance LF transducers for moni- toring. Electromagnetic damping is used to control dynamic offset tendencies at high drive levels.The MF driver has the excursion capability to be

9、 crossed over at 250 Hz. Because of its extreme smoothness, the MF transducer can be crossed over to the HF unit at 2.2 kHz, providing nearly a decade- wide range of low distortion performance. The HF unit, a damped titanium 25 mm dome, is integrated with an Elliptical Oblate 2 clarify the differenc

10、es between them. At 2A we show details of JBLs standard magnetic structure. Magnetic flux Bcrosses the gap in which a coil of wire of length lis placed.The voice coil has an electrical resis- tance Re.These quantities establish the value of (Bl)2/Re. Now, let us look at the Differential Drive topolo

11、gy shown at 2B. In this design there are two magnetic gaps with opposite flux. The two voice coils are connected in reverse so that the mechanical forces they produce will add (be in-phase). For the moving mass to remain the same, the two voice coils must have the same height and half the thickness

12、as in the standard case.The value of B will remain the same. When these changes are made, the total length (l) of the voice coil will be doubled and the resistance-per-unit length of wire will be doubled, since the cross-sectional area has been halved.The total resistance of both coils in series wil

13、l then be four times what it was in the standard case shown at 2A. Since (Bl)2will have quadrupled (remember that l has doubled), the new value of (Bl)2/Rewill be (2Bl)2/4Re.This is equal to 4(Bl)2/4Re, which of course reduces directly to (Bl)2/Re. In terms of electrical-to-mechanical cou- pling the

14、 two approaches are identical; but in other areas we have gained a great deal: 1.The new voice coil assembly now has twice the surface area of the old one.This means that it will have twice the heat dissipa- Spheroidal waveguide with nominal 60 by 100 dispersion. This technical note will cover all a

15、spects of the system design, beginning with the trans- ducers.We then move on to the details of enclosure/baffle and low-loss porting design, and dividing network considerations. Finally, we will present comprehensive measure- ments on all aspects of system performance: 1.The LSR principle; response

16、 data and directivity curves 2. Harmonic distortion measurements 3. Port compression measurements 4. Power compression measurements 5. Impulse response measurements 6. Impedance measurements 7. Network high frequency adjustment. 2.Transducers: 2.1 Low frequency (LF) transducer: Figure 1 shows a sect

17、ion view of the LF transducer. Note that there are two voice coils wound along the same axis and spaced approximately 36 mm, center to center.The neodymium magnet is located in the center of the structure. Note the shorted coil located midway between the two drive coils. We can get a clearer underst

18、anding of the advantages of Differential Drive by comparing it with an equivalent single coil structure, as shown in Figure 2.We use the term “equiva- lent” in that this comparison of both motor structures will have the same electromechan- ical coupling coefficient, (Bl)2/Re, and also the same movin

19、g mass.We will analyze the two structures in parallel, so to speak, in order to Figure 1.Woofer Cutaway Figure 2.Comparison of Standard and DCD technology 3 tion of the old coil, which translates directly into twice the power (+3 dB) input capability for a given operating temperature and observed am

20、ount of dynamic compression. 2.The new voice coil structure will have less effective inductance than the standard one, since the reverse wound coils will have negative mutual inductance between them. This translates into a flatter impedance curve at higher frequencies, producing more acoustical outp

21、ut for a given drive signal. 3.The compact nature of the Differential Drive magnet structure requires much less iron in the magnetic return path. As a result, a Differential Drive transducer can weigh as little as one-third the equivalent standard design.The small overall magnet structure can be con

22、veniently nested in a large heat sink for efficient dissipation of heat from the coils. The LF cone is a carbon fiber composite that has an optimum combination of internal damping and stiffness.The outer suspension is a half-roll butyl rubber ring that provides a broadband termination for the cone,

23、ensuring smooth response at upper frequencies and long term reliability. The 252G also has a third shorted coil which operates as a dynamic brake. At nor- mal operating levels, the shorted coil has no function except to provide the target moving mass of the transducer. However, at higher operating l

24、evels, the shorted coil will move alternately in and out of the two magnetic flux regions.The induced current will act in oppo- sition to the force generated by the voice coil current, progressively damping, or braking, the peak excursions of the moving system. While this at first appears to be dist

25、ortion generation, it is the opposite! The nonlinearity generated by the damping coil is in opposi- tion to the dynamic instability of Bl product seen by the drive coils at their excursion extremes, and thus counteracts that loss, resulting in lower overall distortion at high cone displacements. 2.2

26、 Midrange transducer: A section view of the MF transducer is shown in Figure 3. It is a neodymium motor design and has a 50 mm (2 in) edge wound voice coil for high power handling capability. The cone is of woven Kevlar, and the outer surround is a half roll of butyl rubber.The transducer has suffic

27、ient excursion range and linearity to enable it to be crossed over at 250 Hz, operating comfortably at rated input power. It is essentially free of the midrange distortion characteristic typical of similar dri- vers operating in the 250 Hz range at high levels. 2.3 High frequency transducer: The HF

28、transducer is a 25 mm (1 in) smooth titanium dome that is damped by a thin coat of Aquaplasas well as a unique low recovery foam in the rear cavity. Its fre- quency response extends smoothly beyond 20 kHz. Figure 4 shows a vertical section view of the elliptical oblate spheroidal wave- guide that lo

29、ads the diaphragm. Figure 3.C500G Midrange Cutaway Figure 4.053ti HF Cutaway 4 3. Enclosure and baffle details: Figure 5 shows the two orientation options of the LSR32 system.The MF/HF section may be positioned inboard or outboard, depending on the width of the stereo sound- stage desired. Note that

30、 all orientations per- mit the MF and HF elements to be positioned vertically, ensuring consistent maintenance of LSR coverage angles. It is worth noting that system response is virtually the same, regardless of the position- ing of the baffle plate. The baffle itself is made of a carbon fiber compo

31、site that has a thickness of 38 mm. It is virtually resonance free and is comple- mented by enclosure walls that are braced. As we engineer better transducers with lower distortion, we find that enclosure resonances, even those produced by conventionally good, sturdy design, may be heard as such and

32、 contribute to a distortion “signature”. It is the next step in refinement of system perfor- mance to reduce them. Another source of distortion at high levels has been port turbulence, which occurs at enclosure resonance when cone excursion is at a minimum and air volume velocity through the port is

33、 at a maximum. Under that condi- tion, air particle velocity will also be maxi- mum, creating the “breathing” noises com- monly noted. Contouring the port tube is one method of minimizing this effect. Figure 6 shows a section view of the enclosure through the port tube. Note the continuous flare thr

34、ough the tube. 4. Dividing network design and performance: The network makes use of fourth-order Linkwitz-Riley acoustic response filters.The high slopes have the advantage of minimiz- ing lobing between adjacent elements in the regions of crossover.This is a crucial element in our efforts to assure

35、 smooth response throughout the target listening window. All network elements in the primary signal paths are of the highest quality including low loss capacitors and high saturation current, low distortion industors. Figure 7 shows the on-axis acoustical contributions of each dri- ver. Here, the -6

36、 dB (in-phase) relationships at both crossover points can be seen. 5. Performance measurements: 5.1 The LSR principle; axial measurements and directivity: Harman International research activities in loudspeaker measurements have developed Figure 7.Acoustic Contribution Figure 5.Horizontal and Vertic

37、al Orientation Figure 6.Linear Dynamics Aperture 5 a family of response curves that convey much information for the user regarding the performance of a loudspeaker in a typical lis- tening environment.The raw data for the analysis involves a set of anechoic axial fre- quency response measurements ma

38、de at angular intervals of 5 degrees in both hori- zontal and vertical planes.That data is weighted and averaged to produce the follow- ing plots of level versus frequency: 1. On-axis response. 2. Averaged response over a nominal lis- tening window which is 30 in the hori- zontal plane and 15 in the

39、 vertical plane. 3. Averaged simulated early reflections arriving 5 to 10 msec after the direct sound and lasting for approximately 10 to 20 msec. 4.Total radiated sound power. 5. Directivity index of sound power. 6. Directivity index of early reflections. Taken as a group, this family of six curves

40、 will to a very large extent, define a loud- speakers interaction with the listening space and give a clear indication of how listeners will respond to the system.The on-axis curve serves as a reference.The on-axis data and the averaged listening window data, present- ed in curve 2, will not vary gr

41、eatly from each other in a well executed design. The third curve is a calculation that simu- lates the ensemble of early reflections from walls, floor and ceiling.This curve normally tilts downward, showing the tendency of all loudspeakers to become more directional at higher frequencies. It is impo

42、rtant that the general trend of this curve be free of any response irregularities, especially those that do not occur in the listening window curve. The fourth curve is a calculation of total radiated sound power from the loudspeaker. It is a measurement of the total acoustical energy radiated into

43、the reverberant field of the listening room.This curve falls with rising frequency, indicating the normal tendency of all loudspeakers to become more directional with rising frequency. As with the previous curves, this one should also be uniform and free of irregularities. Curve 5 shows the directiv

44、ity index of the early reflections curve. Mathematically, this is the difference between the direct sound curve and the early reflections curve expressed in dB. Curve 6 is the directivity index of the total radiated sound power. It is the typical directiv- ity index curve seen on many loudspeaker sp

45、ecification sheets and represents the ratio in dB between sound radiated on-axis and the integration of sound radiated from the loudspeaker in all directions. As an example, we show in Figure 8 this family of curves for the LSR32 system.The on-axis response is virtually flat (+1.0 dB, -1.5 dB); the

46、listening window shows a slight divergence from on-axis at high frequencies, but is free of any abrupt variations.The aver- aged early reflections curve is likewise free of any abrupt variations, but shows slightly more roll-off at higher frequencies. As an example of an earlier three-way loudspeake

47、r system designed with attention primarily on attaining a flat on-axis response, we show the data of Figure 9. Note that the on-axis curve is fairly flat, but that the listen- ing window and early reflections curves show clear irregularities. Figure 8.LSR32 Curves 1 2 3 4 5 6 Figure 9.LSR Curves of

48、Earlier Design 1 2 3 4 5 6 6 5.2 Second and third harmonic distortion data: Plots of second and third harmonic distor- tion have traditionally been presented by JBL at various nominal operating levels.Typically, we will show the data for a level of 96 dB as measured at one meter.Those models intende

49、d for higher level applications may have their distortion at measured 102 dB as well. Distortion data for 1 m on-axis SPL levels of 96 dB and 102 dB are presented in figures 10A and 10B, respectively. In these curves the distortion components have been raised 20 dB for convenience in reading. Note in Figure 10A that the level of both distortion components in the frequency range above 100 Hz is -40 dB or lower, relative to the fundamental.This corresponds to distor- tion of less than 1% and represents unusual- ly fine performance at such a high acoustical output level.The data taken a