《JVC-MXGC5-cs-sm 维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《JVC-MXGC5-cs-sm 维修电路原理图.pdf(68页珍藏版)》请在收音机爱好者资料库上搜索。
1、MX-GC5MX-GC5ContentsCOPYRIGHT 2005 Victor Company of Japan,LimitedSafety precautions - 1- 2Preventing static electricity - 1- 3Important for laser products - 1- 4Disassembly method - 1- 5Adjustment method - 1- 18Flow of functional operation until TOC read - 1- 20Maintenance of laser pickup - 1- 21Re
2、placement of laser pickup - 1- 21Description of major ICs - 1- 22SERVICE MANUALCOMPACT COMPONENT SYSTEMArea SuffixJ . U.S.A.C . CanadaSP-MXGC5SP-MXGC5CA-MXGC5RadioFans.CN 收音机爱 好者资料库Warning ! CAUTIONGood earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/v1500 10Wolt
3、s,or more sensitivity)0.15 F AC TYPESafety Precautions1. This design of this product contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer.
4、Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterations of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additi
5、ons will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resulting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evid
6、ent from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical componen
7、ts having such features are identified by shading on the schematics and by ( ! ) on the Parts List in the Service Manual. The use of a substitute replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create
8、shock, fire, or other hazards. 4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required
9、, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling. 5. Leakage currnet check (Electrical shock hazard testing) After re-assembling the product, always perform an isolation check on the exposed metal parts o
10、f the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate without danger of electrical shock. Do not use a line isolation transformer during this check.? Plug the AC line cord directly into the AC outlet. Usin
11、g a Leakage Current Tester, measure the leakage current from each exposed metal parts of the cabinet, particularly any exposed metal part having a return path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.)? Alternate check method Plug the AC line
12、cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resistor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground. Measure the AC voltage across the resistor
13、 with the AC voltmeter.Move the resistor connection to each exposed metal part, particularly any exposed metal part having a return path to the chassis, and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. Voltage measured Any must not e
14、xceed 0.75 V AC(r.m.s.). This corresponds to 0.5 mA AC(r.m.s.). 1. This equipment has been designed and manufactured to meet international safety standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance wit
15、h the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector is provided, check setting for local voltage.Burrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such burr
16、s in the case of preforming repair of this system.RadioFans.CN 收音机爱 好者资料库Preventing static electricity1. Grounding to prevent damage by static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laser diode in
17、 the traverse unit (optical pickup). Take care to prevent this when performing repairs.2. About the earth processing for the destruction prevention by static electricityIn the equipment which uses optical pick-up (laser diode), optical pick-up is destroyed by the static electricity of the work envir
18、onment.Be careful to use proper grounding in the area where repairs are being performed.2-1 Ground the workbenchGround the workbench by laying conductive material (such as a conductive sheet) or an iron plate over it before placing the traverse unit (optical pickup) on it.2-2 Ground yourselfUse an a
19、nti-static wrist strap to release any static electricity built up in your body.3. Handling the optical pickup1. In order to maintain quality during transport and before installation, both sides of the laser diode on the replacement optical pickup are shorted. After replacement, return the shorted pa
20、rts to their original condition. (Refer to the text.)2. Do not use a tester to check the condition of the laser diode in the optical pickup. The testers internal power source can easily destroy the laser diode.4. Handling the CD changer unit (optical pickup)1. Do not subject the CD changer unit (opt
21、ical pickup) to strong shocks, as it is a sensitive, complex unit.2. Cut off the shorted part of the flexible cable using nippers, etc. after replacing the optical pickup. For specific details, refer to the replacement procedure in the text. Remove the anti-static pin when replacing the CD changer u
22、nit. Be careful not to take too long a time when attaching it to the connector.3. Handle the flexible cable carefully as it may break when subjected to strong force.4. It is not possible to adjust the semi-fixed resistor that adjusts the laser power. Do not turn it.Attention when traverse unit is de
23、composed* Please refer to “Disassembly method” in the text for pick up and how to detach the CD changer mechanism.1. Remove the CD changer unit.2. Disconnect the harness from connector on the CD motor board.3. Solder is put up before the card wire is removed from connector Cn601on the main board as
24、shown in Fig.A and Fig. B. (When the wire is removed without putting up solder, the CD pick-up assembly might destroy.)4. Please remove solder after connecting the card wire with CN601 when you install picking up in the substrate.Conductive material (conductive sheet) or iron plate(caption)Anti-stat
25、ic wrist strapSolderingFig.BFlexible cableFig.ACD changer unit1. CLASS 1 LASER PRODUCT2. DANGER : Invisible laser radiation when open and inter lock failed or defeated. Avoid direct exposure to beam.3. CAUTION : There are no serviceable parts inside the Laser Unit. Do not disassemble the Laser Unit.
26、 Replace the complete Laser Unit if it malfunctions.4. CAUTION : The compact disc player uses invisible laser radiation and is equipped with safety switches which prevent emission of radiation when the drawer is open and the safety interlocks have failed or are defeated. It is dangerous to defeat th
27、e safety switches. Important for laser productsFUSE CAUTIONCAUTION: REPLACE WITH SAME TYPEAND RATING FUSE (S).ATTENTION:REMPLACER PAR UN(LES)FUSIBLE(S) DE MEME TYPE ET DE MEME VALEUR5. CAUTION : If safety switches malfunction, the laser is able to function.6. CAUTION : Use of controls, adjustments o
28、r performance of procedures other than those specified herein may result in hazardous radiation exposure. ! CAUTION Please use enough caution not to see the beam directly or touch it in case of an adjustment or operation check. Disassembly methodCommence disassembly of the set by removing the main u
29、nits and then proceed to the components and assemblies inside the units. Replacement of the fuses and the power IC? Top cover? CD changer unit? Front panel assembly ? CD changer unit? Removing the main PCB? Removing the CD changer mechanism assembly? Removing the CD pickup? Replacing the loading mot
30、or and belt of the CD changer tray? Replacing the CD tray rotor belt of CD changer, and removing the motor? Front panel assembly? Removing the (USB, AUX jack) earphone jack PCB? Removing the control/FL PCB? Removing the volume, preset and CD Function switch PCB? Removing the remote sensor PCB? Remov
31、ing the standby Led PCB? Removing jack Led backlight PCB? Removing Sound mode PCB 1-5Replacement of the fuses and the power IC? Replacing the fuses (See Fig.1) ? Prior to performing the following procedure, remove the left side BOARD. 1. Replace the fuses inside.Caution Be sure to use fuses with the
32、 specified ratings.? Replacing the heat sink cover (See Fig.3)1. Remove four screws B from the rear panel.2. Remove four screws E from the heat cover.3. Pull the heat sink cover outward.? Replacing the power IC (See Fig.2) ? Prior to performing the following procedure, remove the top cover.1. Remove
33、 the two screws A from the heat sink between the power IC(STK412-430)2. Remove the four screws B from the heat sink the between the power IC (D1889,B1340)3. Remove the solder fixing the power IC.AAFig.2Fig.1Fig.3BEFuse (F901)3.5A 125VFuse (F902)1.6A 250VBFig.5? Removing the top cover (See Fig.4 and
34、5)1. Remove six screws C that retain the top cover from the panel rear of the body.2. Remove six screws D that retain the top cover from the two sides of the body.3. Remove the top cover from the body by lifting it toward the rear.Top coverFig.4Right Front panel assemblyLeft Front panel assemblyDDDD
35、Fig.6Fig.9? Removing the CD changer unit(See Fig.6 to 9)? Prior to performing the following procedures, remove the top cover.Caution Although the CD mechanism unit can be removed without removing the CD tray panel, it is still recommended to remove it in order to prevent damage.a. From the front pan
36、el side of this set, push in the sections marked with arrows and pull out the CD tray toward the front.b. Remove the CD tray panel by pushing both of its extremities upward in the direction of the arrows.c. Push the CD tray deep into the set. 1.Disconnect the cord wires from the main PCB CN401,CN601
37、,CN501 and CN203.2. From the rear of the set, remove two screws E, two screws F and four screws G on the front panel left and right side.3. Handle the CD changer unit rear, take out the unit.Fig.7Fig.8FEFAntennaterminalGCD tray panelCD tray panel? Removing the front panel assembly(See Fig.10 to 11)?
38、 Prior to performing the following procedures, remove the top cover. ? Also remove the CD changer unit.1. Disconnect the parallel wire and the cord wire from the connectors CN201, CN401 on the main PCB.2. Remove one screws H retaining the front panel assembly onto the bottom of the body.3. Remove tw
39、o screws I on the left and right side of the set retaining the panel front from the bottom and then remove then GND lug b that comes from the power amp and supply PCB.4. Disengage the claws c on both sides of the front panel assembly and then remove the assembly.Fig.10HFig.11Claw cGND lug bFig.13CD
40、PCBShort round CN601Fig.12? Removing the MAIN PCB (See Fig.12 to 13)? Prior to performing the following procedures, remove the top cover. ? Also remove the CD changer unit.1. Disconnect the wires from CN701, CN702 and CN703 on the CD PACK PCB, which is located on the down side of the CD changer unit
41、.2. The four screws J that retain the CD PCB should be removed.3. Remove the CD PCB by pulling it toward the side where the CN701 is located.4. Using solder, short the CD pickup to connect to short round.Caution After re-connecting the wires, be sure to remove the shorting solder from the GND connec
42、tion.5. Disconnect the card wire from the connector CN701 on the main PCB and then remove the main PCB.JCD PCBJJFig.14Fig.15assemblye ( Green color )e ( Red color )e ( Green color )e ( Red color ) dCD changerunit? Removing the CD changer mechanism assembly (See Fig.14 to 15)? Prior to performing the
43、 following procedures, remove the top cover. ? Also remove the CD changer unit.1. Turn the CD changer mechanism cover base and remove the screws d connecting the unit to the CD changer mechanism assembly.2. Removing four screws e retaining the CD mechanism holder assembly.Caution When replacing the
44、CD changer mechanism assembly, be sure not to mistake the positions of the silver color and copper color spring.CD changermechanismFig.16Fig.17Fig.18Motor lockerTurn table motorObligue gear, and then remove the CD traygMLfCD pickupShaft? Removing the CD pickup (See Fig.16) ? Prior to performing the
45、following procedures, remove the top cover. ? Also remove the CD changer unit. ? Also remove the CD changer mechanism.1. Widen the section f.2. While keeping the section f wide open, push the section g in the direction of the arrow to remove the shaft, and then remove the CD pickup.? Replacing the l
46、oading motor and rotor belt of the CD changer (See Fig .17)? Prior to performing the following procedures, remove the top cover. ? Also open the CD changer tray.1. Remove the two screws L retaining the CD changer tray loading motor.2. Remove the two screws M retaining the gear plate and take it out,
47、 after remove the rotor belt from the pulley.? Replacing the CD turn table and remov-ing the motor (See Fig. 18 )? Prior to performing the following procedures, remove the top cover. ? Also remove the CD changer unit.1. Remove the one screws N retaining the CD (Turn table).2. Remove the two screws O
48、 retaining the stopper brackets on both sides of the CD changer unit.3. Remove the stopper brackets from both sides of the CD changer unit.4. Pull out the CD tray from the CD changer unit, all the way and lift the tray (u/ ward) to remove.5. Remove the gear and after push out the tray motor locker a
49、nd pull out the tray motor from the CD tray. Fig.20Fig.19SQR( 17PCS)TZPLFront panelassemblyRemote sensor PCBStandby Led PCBFig.21? Removing the USB,AUX,earphone PCB (See Fig.19)? Prior to performing the following procedures, remove the top cover. ? Also remove the CD changer unit. ? Also remove the
50、front panel assembly. Remove six screws Z retaining the USB,AUX, earphone PCB.? Removing the remote sensor PCB & the standby PCB (See Fig.20)? Prior to performing the following procedures, remove the top cover. ? Also remove the CD changer unit. ? Also remove the front panel assembly.1. Remove four