《Skanti_TRP9250_serv.pdf》由会员分享,可在线阅读,更多相关《Skanti_TRP9250_serv.pdf(289页珍藏版)》请在收音机爱好者资料库上搜索。
1、TRP 9250 250 Watt Radio Transceiver for MF/HF SKANTI SKANTI TRP 9250 Technical Manual SkandinaviskTeleindustri SKANTI A/S 4 Lautrupvang DK-2750 Ballerup, Denmark Phone: +45 44 74 84 00 Fax: +45 44 74 84 01 Telex 37292 skanti dk E-mail skantiskanti.dk http:/www.skanti.dk phkqf=qom=VORM ORM=t o=q =jc=
2、L=ec q=j Skandinavisk Teleindustri SKANTI A/S 4 Lautrupvang, DK-2750 Ballerup, Denmark Please note Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed. The information in this manual is furnished for informati
3、onal use only, is subject to change without notice, may contain errors or inaccuracies, and represents no commitment whatsoever. This agreement is governed by the laws of Denmark. Doc. no.: 910 000 88Issue: B9912 TRP 9250 TECHNICAL MANUALI TABLE OF CONTENTS TABLE OF CONTENTS 1. INTRODUCTION Table of
4、 Contents . .1-1 General Description.1-3 Basic Versions .1-4 Technical Data .1-6 2. OPERATION Transceiver Control Unit Keys and Annunciators.2-3 Symbol explanation.2-7 Operating instructions .2-8 Operation related Prog key operations .2-49 Propagation of HF and MF Radiowaves .2-55 3. INSTALLATION Mo
5、unting The Units .3-3 Powersupply .3-10 Battery Charger .3-12 Earth Connections .3-14 Antennas .3-15 Recommended ATU Installation .3-15 Interconnection of Units .3-16 Connectors for External Equipment .3-19 Transceiver Control Unit connector panel .3-19 Transceiver Unit terminal strip panel .3-23 Fi
6、nal installation Check .3-27 Configuration Prom .3-29 Installation related Prog key operations .3-45 Configuration .3-49 Installation Wiring Diagrams. 3-69 4. TECHNICAL DESCRIPTION Transceiver Control Unit 9000 .4-3 Transceiver Unit TU 9250 .4-4 Antenna Tuning Unit ATU 9250 .4-8 Block Diagrams .4-9
7、5. SERVICE Preventive Maintenance .5-3 Trouble Shooting .5-7 Power Protection .5-8 Service related Prog key operations.5-17 Self Test .5-25 6. DSC OPERATION General .6-2 Operating instructions.6-8 Programming.6-54 Test .6-68 7. DSC INSTALLATION Description .7-3 Mounting the units .7-3 Figures and ta
8、bles .7-4 Installation configuration .7-18 ffqom=VORM=qbekfi=jkri 1. INTRODUCTION Table of Contents General Description 1-3 Basic Versions 1-4 Technical Data 1-6 1. INTRODUCTION Table of Contents INTRODUCTION TRP 9250 TECHNICAL MANUAL 1-1 INTRODUCTION 1-2TRP 9250 TECHNICAL MANUAL GENERAL DESCRIPTION
9、 The TRP 9250 is a general purpose HF SSB transceiver designed for maritime applications covering the frequency range 1.6 - 30 MHz. The standard version offers simplex and semiduplex radiotelephone communication in the maritime mobile bands and is intended for installation in voluntarily as well as
10、compulsor- ily fitted vessels. With the optional built-in DSC and Radiotelex the TRP 9250 forms a inte- grated communication system ideal for simplified GMDSS installations. The TRP 9500 can be fitted in the SKANTI COMBRIDGE communication system for GMDSS. The TRP9250 consists of a compact Trans- ce
11、iver Control Unit, a fully remote controlled Transceiver Unit and an automatic Antenna Tuning Unit. The Transceiver Control Unit, Transceiver Unit and Antenna Tuning Unit may be installed 100 m apart using standard screened cables. One or two Control units are easily connected to the same transceive
12、r unit increasing the flexibility of the installation. The Transceiver Control Unit contains all re- ceiver and transmitter operating controls. It is fully push-button controlled by means of a splash-proof keyboard with tactile and audible feed-back . The LCD-display shows several information includ
13、ing receive and transmit fre- quencies, the mode of operation and time of day. Back-light with dimmer function is in- cluded for both LCD-display and keyboard to ease operation in any light condition. Mode, receive and transmit frequency set-ups can be stored and recalled directly from keyboard or u
14、sed in conjunction with the 10 scan programs. Sweeping of a selected frequency range is also possible with the sweep function. Where required by authorities transmitter frequencies can be preprogrammed into a PROM allowing transmission only on these frequencies. The compact Transceiver Control Unit
15、is easily in- stalled horizontally as well as vertically and with the optional rotatable wedge tilted to fit any installation. The Transceiver Unit contains all receiver and transmitter circuitry and all connections for ex- ternal equipment. The standard equipment has a built-in two-tone alarm gener
16、ator and single key selection of 2182kHz. A squelch circuit, an low noise RF-amplifier and RF-atte- nuator are also included. The transceiver is fully synthesized and the receiver may be tuned in selectable steps of 1kHz, 100Hz and 10Hz. The fully protected solid state 250W Power Amplifier, cooled b
17、y forced convection, mat- ches a 50 ohms antenna system, but is normally used in connection with the Antenna Tuning Unit. In the standard version, the transmitter covers the marine bands between 1.6 to 30MHz, but an optional PA-filter is available which give continuous coverage of the frequency rang
18、e 1.6 to 30MHz. The microprocessor controlled Antenna Tun- ing Unit tunes automatically to all antennas between 7 and 18 meters and requires no presetting at the installation. The typical tune time is less than to 0.5s. The TRP 9250 is designed for 24V DC oper- ation. Mains operation is possible wit
19、h the optional AC Power Supply Assembly installed in the Transceiver Unit. A Battery Charger Extension enables the AC Power Supply As- sembly to be used as a battery charger. The built-in test facilities and easy-to-replace module design of the TRP 9250 simplifies the service concept. GENERAL DESCRI
20、PTIONINTRODUCTION TRP 9250 TECHNICAL MANUAL1-3 BASIC VERSIONS TRP 9250 Marine HF-SSB Radio System 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex operation. 896 Pre-Programmable Frequencies in the ITU Marine Bands. Free RX Frequency. ITU Frequencies Pre-Programmed. Labelling of Units. Transce
21、iver Control Unit Type TCU 9000 S, Transceiver Unit Type TU 9250 S, Antenna Tuning Unit Type ATU 9250. TRP 9251 Marine HF-SSB Radio System 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex operation. Free TX frequency selection in the ITU Marine Bands. Free RX Frequency. ITU Frequencies Pre-Pro
22、grammed. Labelling of Units. Transceiver Control Unit Type TCU 9000 S, Transceiver Unit Type TU 9251 S, Antenna Tuning Unit Type ATU 9250. TRP 9252 Marine HF-SSB Radio System with CW facility 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex operation. CW operation Free TX frequency selection i
23、n the ITU Marine Bands. Free RX Frequency. ITU Frequencies Pre-Programmed. Labelling of Units. Transceiver Control Unit Type TCU 9002 S, Transceiver Unit Type TU 9252 S, Antenna Tuning Unit Type ATU 9250. TRP 9253 Marine HF-SSB Radio System 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex Oper
24、ation. Free TX Frequency Selection 1.6 - 30MHz. Free RX Frequency. ITU Frequencies Pre-Programmed. Labelling of Units. Transceiver Control Unit Type TCU 9000 S, Transceiver Unit Type TU 9253 S, Antenna Tuning Unit Type ATU 9250. INTRODUCTIONBASIC VERSIONS 1-4TRP 9250 TECHNICAL MANUAL TRP 9254 Genera
25、l Purpose HF-SSB Radio System 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex operation. Free TX Frequency Selection 1.6 - 30MHz. Free RX Frequency. Labelling of Units. Transceiver Control Unit Type TCU 9004 S, Transceiver Unit Type TU 9254 S, Antenna Tuning Unit Type ATU 9250. TRP 9255 Gener
26、al Purpose HF SSB-Radio System with CW facility 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex operation. CW operation Free TX Frequency Selection 1.6 - 30MHz. Free RX Frequency. Labelling of Units. Transceiver Control Unit Type TCU 9005 S, Transceiver Unit Type TU 9255 S, Antenna Tuning Uni
27、t Type ATU 9250. TRP 9257 Marine HF-SSB Radio System with CW facility 250 Watt P.E.P. Power Amplifier. Simplex / Semi-duplex Operation. CW operation Free TX Frequency Selection 1.6 - 30MHz. Free RX Frequency. ITU Frequencies Pre-Programmed. Labelling of Units. Transceiver Control Unit Type TCU 9002
28、S, Transceiver Unit Type TU 9257 S, Antenna Tuning Unit Type ATU 9250. BASIC VERSIONSINTRODUCTION TRP 9250 TECHNICAL MANUAL1-5 TECHNICAL DATA GENERAL Complies with the relevant IMO performance standards, the ITU Radio Regulations, the relevant ITU-R recommendations and meets the performance specific
29、ations of ETSI and CEPT. Complies with the relevant CE-marking standards. Frequency Range: 1.6 - 30 MHz Frequency Generation: True digital frequency synthesis. Frequency Selection: Direct by the keyboard. Up to 896 single pre-programmed frequencies with direct recall of the first 200. All relevant I
30、TU frequencies. GMDSS Safety and Distress frequencies. 100 user-programmable channels (RX/TX fre- quency pair). Single key selection of 2182 kHz Scanning facilitiy Sweep facility Frequency Presentation: Backlit LCD display with simultaneous presen- tation of receive and transmit frequencies. Frequen
31、cy Stability: 0.35 ppm 0.1 ppm (optional) Aging: Less than 1 ppm/year Operating Modes: Simplex and semiduplex SSB: Upper sideband suppressed carrier (J3E, USB). Same as USB. LSB: Lower sideband suppressed carrier (J3E, LSB). R3E: Upper sideband reduced carrier (R3E). AM: Reception/Transmission: Comp
32、atible AM single sideband full carrier (H3E). Reception: Double sideband full carrier (A3E). TLX: Reception/Transmission: Single side- band suppressed carrier with modulating sub-carrier (J2B). Sub-carrier user-programmable from 1500 Hz to 2950 Hz, default 1700 Hz. Reception: Frequency shift keyed c
33、arrier (F1B). CW: Morse telegraphy keyed carrier(A1A) Displayed Frequency: Operating modes SSB (USB), LSB, R3E, AM: Carrier Frequency. Operating mode TLX: Upconverted sub-carrier frequency Operating mode CW: Carrier frequency Other Facilities: Real time clock User-programmable Sleep Timer with up to
34、 10 setups Built-in selftest programme Continouosly operating Power and Protection Monitor. Supply Voltage: 24V DC With optional built-in AC Power Supply: 115/230 V AC (internal switch). Automatic changeover to DC in the absence of AC sup- ply. Operating Temperature Range: -20 deg. C to +55 deg. C C
35、ompass Safe Distance: Refer to table at page 1-10 RECEIVER CHARACTERISTICS Frequency Range: 100 kHz to 30 MHz (10 kHz to 150 kHz with reduced performance). Frequency Resolution: 100 Hz by keyboard entry. 10 Hz, 100 Hz or 1 kHz with the search/fine tuning facility. Antenna Impedance: 50 ohm. Automati
36、cally matched by the An- tenna Tuning Unit. INTRODUCTIONTECHNICAL DATA 1-6TRP 9250 TECHNICAL MANUAL Input Protection: 30 V RMS (EMF) for up to 15 min. IF Selectivity: SSB: 350 Hz to 2.7 kHz AM: +/- 3 kHz TLX: +/- 150 Hz (optional) CW: +/- 150 Hz, +/- 1.20 kHz and +/- 3.00 kHz (relevant versions only
37、) Sensitivity: Antenna input for 10 dB SINAD, 50 ohm an- tenna. SSB: 0.6 V AM: 4 V TLX: 0.25V CW: 0.25 V with +/- 150 Hz bandwidth When HiSens is selected, the sensitivity is increased by approx. 5 dB. Out-of-band Intermodulation: Two 93 dBV signals more than 30 kHz off tune produces less output tha
38、n an equivalent input signal of 30 dBV. In-band Intermodulation: Less than -40 dB. Cross Modulation: Unwanted signal of 105 dBV/30%-400Hz more than 20 kHz offset from receiver fre- quency, produces cross modulation less than -30dB relative to wanted signal of 60 dBV/SSB. Blocking: With a wanted sign
39、al of 60 dBV, an unwanted signal 20 kHz off tune 110 dBV will affect the output level by less than 3 dB or cause a reduction in SINAD of less than 6 dB (SSB). Reciprocal Mixing: With a wanted signal giving 20 dB SINAD, an unwanted signal 20 kHz off tune and 80 dB above the wanted signal level will c
40、ause less than 6 dB reduction in SINAD (SSB). Image Rejection: Greater than 80 dB. IF Rejection: Greater than 80 dB. Spurious Response Rejection: Greater than 80 dB. Internally Generated Spurious Signals: Less than 5 dB SINAD (SSB). Spurious Emission: Less than 20 pW/50 ohm at antenna connector RF-A
41、mplifier: HiSens selected: Gain 12 dB HiSens not selected: Gain 0 dB RF-Attenuator: Att selected: Attenuation 20 dB Att not selected: Attenuation 0 dB Squelch: Voice controlled squelch. Line Output : -10 dBm to +10 dBm, 600 ohm. Audio Output Power: Internal speaker: 6 W with less than 10% dis- torti
42、on. External speaker: 6 W in 8 ohm with less than 10% distortion. TRANSMITTER CHARACTERISTICS Output Power: 250 W PEP into 50 ohm, voice, DSC or ARQ telex, 150 W PEP into 50 ohm, FEC telex, AC supply or min. 26 V DC. Single Tone max. Power: 250 W CW into 50 ohm for a duty cycle less than 55% and a m
43、odulation rate greater than 3 baud. Reduction to 100 W when continuously keyed during 1 min. Automatic full power recovery after 1 min. Power Reduction: Medium: 100 W, 60 W or 20 W (user-pro- grammable, default 60 W) Low: approx. 10 W TECHNICAL DATAINTRODUCTION TRP 9250 TECHNICAL MANUAL1-7 Frequency
44、 Range Continuous coverage: 1.605 MHz - 30 MHz ITU Marine Bands: 2Mhz = 1.605 - 4.000 MHz 4MHz = 4.000 - 4.438 MHz 6MHz = 6.200 - 6.525 MHz 8MHz = 8.100 - 8.815 MHz 12MHz = 12.230 - 13.200 MHz 16MHz = 16.360 - 17.410 MHz 18MHz = 18.780 - 18.900 MHz 19MHz = 19.680 - 19.800 MHz 22MHz = 22.000 - 22.855
45、 MHz 25MHz = 25.070 - 25.210 MHz 26MHz = 26.100 - 26.175 MHz Frequency Resolution: 100 Hz step Intermodulation: Better than -31 dB PEP in standard two-tone test Hum and Noise: Less than -50 dB PEP (SSB) Spurious Emissions: Less than 43 dB/PEP, typical better than 60 dB/PEP Supression of Unwanted Sideband: Greater than 60 dB/PEP (1 kHz, SSB) Line Input: -10