《Yamaha-HTR-5140-5140-RDS-Schematic电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-HTR-5140-5140-RDS-Schematic电路原理图.pdf(68页珍藏版)》请在收音机爱好者资料库上搜索。
1、100650 AV RECEIVER RX-V495/RX-V495RDS/ HTR-5140/HTR-5140RDS TO SERVICE PERSONNEL . 1 REMOTE CONTROL PANELS. 1 FRONT PANELS. 2 REAR PANELS . 34 SPECIFICATIONS. 56 INTERNAL VIEW . 7 DISASSEMBLY PROCEDURES . 7 SELF DIAGNOSIS FUNCTION . 819 FACTORY PRESET . 20 ICONTENTS AMP ADJUSTMENT . 21 TUNER ADJUSTM
2、ENT. 2225 IC DATA .2635 DISPLAY DATA . 36 BLOCK DIAGRAM. 3739 PRINTED CIRCUIT BOARD . 4057 SCHEMATIC DIAGRAM . 5865 PARTS LIST . 6681 REMOTE CONTROL TRANSMITTER . 82 SERVICE MANUAL IMPORTANT NOTICE This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
3、It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the users, and have therefore not been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may
4、result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA product owners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT
5、:The presentation or sale of this manual to any individual of firm does not constitute authorization, certification or recognition of any applicable technical capabilities, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the uni
6、t(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to
7、exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the
8、 unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. RadioFans.CN 收音机爱 好者资料库 1 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS TO SERVICE PERSONNEL 1. Critical Components information. Components having special characteristics are marked and must be replaced
9、 with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Model only). When service has been completed, it is imperative that you verify that all exposed conductive surfaces are properly insulated from supply circuits. Meter impedance should be e
10、quivalent to 1500 ohm shunted by 0.15F. Leakage current must not exceed 0.5mA. Be sure to test for leakage with the AC plug in both polarities. WARNING: CHEMICAL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (
11、where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY RE
12、ASON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food. REM
13、OTE CONTROL PANELS U,C,R,T,A and L modelsB and G models WALL OUTLET EQUIPMENT UNDER TEST AC LEAKAGE TESTER OR EQUIVALENT INSULATING TABLE CAUTION F804: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE,REPLACE ONLY WITH SAME TYPE 8.0A, 250V FUSE. CAUTION F804: REPLACE WITH SAME TYPE 8.0A, 250V FUSE. ATT
14、ENTION F804: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 8.0A, 250V FUSE. A V TUNER CD TAPE /MD DVD /LD VCR AMP POWER TV DVD MENU CBL /DBS A/B/C/D/E DISC SKIP PRESET PRG + PRG + TEST CH EFFECT DISP RETURNINDEX S/DA/B VCR RECTV INPUT TITLEMENU TIME/LEVELSET MENU +10+100 CH MUTE TV TV V O L U M E
15、C O D E S E T SELECT ENTERCLEAR SLEEP 213 TUNERCDTAPE/MD 546 TV/DBSDVD/LDVCR V-AUXPHONOEXT. DEC. 879 0 TUNER CD TAPE /MD DVD /LD VCR AMP POWER TV DVD MENU CBL /DBS A/B/C/D/E DISC SKIP PRESET PRG + PRG + TEST CH EFFECT DISP RETURNINDEX S/DA/B VCR RECTV INPUT TITLEMENU TIME/LEVELSET MENU +10+100 CH MU
16、TE TV TV V O L U M E C O D E S E T SELECT ENTERCLEAR SLEEP A 213 TUNERCDTAPE/MD 546 TV/DBSDVD/LDVCR V-AUXPHONOEXT. DEC. 879 0 RAV201 V269020-EU RAV200 V269010-US DIR BDIR A DIR BDIR A RadioFans.CN 收音机爱 好者资料库 2 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS FRONT PANELS M RX-V495 (U, C, R, T, A and L models
17、) M RX-V495RDS (B and G models) M HTR-5140 (U, C, T and A models) M HTR-5140RDS (G model) 3 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS REAR PANELS M RX-V495/HTR-5140 U model M RX-V495/HTR-5140 C model M RX-V495 R model M RX-V495/HTR-5140 T model 4 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS M RX-V495/HTR-5
18、140 A model M RX-V495RDS B model M RX-V495RDS/HTR-5140RDS G model M RX-V495 L model 5 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS FM SECTION Tuning Range U, C models87.5 to 107.9MHz R, T models (Frequency Step: 100kHz) 87.5 to 108.0MHz (Frequency Step: 50kHz) 87.50 to 108.00MHz A, B, G, L models87.50 to
19、 108.00MHz 50dB Quieting Sensitivity (IHF) U, C, R, T models only Mono, 1kHz, 100% mod1.6V(15.3dBf) Stereo, 1kHz, 100% mod23V(38.5dBf) Usable Sensitivity (DIN) A, B, G, L models only DIN, Mono(S/N 26dB)0.9V DIN, Stereo(S/N 46dB)28V Alternate Channel Selectivity U, C, R, T models (400kHz)75dB A, B, G
20、, L models (300kHz) Selectivity(two signals, 40kHz Dev.)55dB Signal-to-Noise Ratio U, C, R, T models (IHF) Mono/Stereo81dB/75dB A, B, G, L models (DIN-Weighted, 40kHz Dev.) Mono/Stereo75dB/69dB Harmonic Distortion (1kHz) Mono/Stereo0.1%/0.2% Stereo Separation (1kHz)48dB Frequency Response (20Hz to 1
21、5kHz)01dB Output Level (1kHz) U, C, R, T models (100% mod.)550mV A, B, G, L models (40kHz Dev.)550mV Antenna Input75 unbalanced SPECIFICATIONS AUDIO SECTION Minimum RMS Output Power Per Channel (Power Amp. Section) MAIN L/R, REAR L/R 20Hz to 20kHz, 0.04% THD, 860W+60W 1kHz, 0.07% THD, 870W+70W CENTE
22、R 20Hz to 20kHz, 0.04% THD, 860W 1kHz, 0.07% THD, 870W Maximum Power (EIAJ) R, T models only MAIN L/R, REAR L/R 1kHz, 10% THD, 895W+95W CENTER, 1kHz, 10% THD, 895W Dynamic Power Per Channel (IHF) MAIN L/R 8/6/4/2 80W+80W/100W+100W/120W+120W/145W+145W DIN Standard Output Power Per Channel G model onl
23、y MAIN L/R, 1kHz, 0.7% THD, 4100W+100W Dynamic Headroom(8) U, C models only1.55dB IEC Power G model only MAIN L/R, 1kHz, 0.04% THD, 865W+65W Power Band Width MAIN L/R, 0.1% THD, 30W, 810Hz to 50kHz Damping Factor (SPEAKER A) MAIN L/R, 20Hz to 20kHz, 860 Input Sensitivity/Input Impedance PHONO (MM)2.
24、5mV/47k CD etc.150mV/47k MAIN L/R (EXTERNAL DECODER)150mV/47k CENTER150mV/40k SURROUND L/R150mV/40k SUB WOOFER150mV/40k Maximum Input Signal Level (1kHz) PHONO (MM), 0.1% THD100mV CD etc. (EFFECT ON), 0.5% THD2.2V Output Level/Output Impedance REC OUT150mV/1.2k SUB WOOFER (MAIN SP : SMALL)4V/1.2K He
25、adphone Jack Rated Output/Impedance CD etc., Input=1kHz, 150mV, RL=80.4V/390 Frequency Response(20Hz to 20kHz) CD etc., MAIN00.5dB RIAA Equalization Deviation PHONO (MM)00.5dB Total Harmonic Distortion(20Hz to 20kHz) PHONO (MM) to REC OUT (1V)0.02% CD etc.(EFFECT OFF) to MAIN SP OUT(30W/8) 0.025% Si
26、gnal-to-Noise Ratio(IHF-A Network) PHONO (MM), Input 5mV shorted, REC OUT U, C, R, T models86dB A, B, G, L models81dB CD etc,(EFFECT OFF), Input 150mV shorted, SP OUT 96dB Residual Noise(IHF-ANetwork) MAIN L/R, SP OUT150V Channel Separation(Vol. 30dB, EFFECT OFF) PHONO, Input shorted, 1kHz/10kHz60dB
27、/55dB CD etc, Input 5.1k terminated, 1kHz/10kHz 60dB/45dB Tone Control Characteristics BASS: Boost/Cut10dB(50Hz) : Turnover Frequency350Hz TREBLE: Boost/Cut10dB(20kHz) : Turnover Frequency3.5kHz Filter Characteristics MAIN, REAR SP SMALL : H.P.F.fc=90Hz, 12dB/oct. SUB WOOFER : L.P.F.fc=90Hz, 18dB/oc
28、t. AM SECTION Tuning Range U, C models530 to 1710kHz R, T models (Frequency Step : 10kHz)530 to 1710kHz (Frequency Step : 9kHz)531 to 1611kHz A, B, G, L models531 to 1611kHz Usable Sensitivity300V/m Signal-to-Noise Ratio52dB Output Level (1kHz, 30% mod.)150mV AntennaLoop antenna 6 RX-V495/RX-V495RDS
29、/HTR-5140/HTR-5140RDS GENERAL Power Supply U, C, modelsAC120V, 60Hz R modelAC110/120/220/240V, 50/60Hz T modelAC220V, 50Hz A modelAC240V, 50Hz B, G, L modelsAC230V, 50Hz Power Consumption U model230W C model260W/340VA R, T models230W A, B, G, L models230W Maximum Power Consumption R model only 5CH S
30、imultaneous output, 10% THD630W AC Outlet U, C, R, T, G, L models, Switched x 2100W max(Total) U, C, R, T, A models11.2kg(24Ibs. 11 oz) B, G models11.5kg(25Ilbs, 5 oz) A, B models, Switched x 1100W max Dimensions(W x H x D)435 x 151 x 391mm (17/1/8 x 5-15/16 x 15-3/8) Weight AccessoriesAM loop anten
31、na x 1 Indoor FM antenna x 1 Remote Control Transmitter x 1 Battery (size AAA, R03) x 4 * Specifications subject to change without notice. U . U. S. A. modelA .Australian model C . Canadian modelB .British model R . General modelG .European model T. China modelL .Singapore model VIDEO SECTION Video
32、Signal Type U, C modelsNTSC R modelNTSC/PAL T, A, B, G, L modelsPAL Video Signal Level1Vp-p/75 Maximum Input Level1.5Vp-p Signal-to-Noise Ratio50dB Monitor Output Frequency Response(3dB) 5Hz10MHz DIMENSIONS Manufactured under license from Dolby Laboratories Licensing Corporation.DOLBY , AC-3, Pro Lo
33、gic, and the double-D symbol are trademarks of Dolby Laboratories Licensing Corporation. Copyright 1992 Dolby Laboratories, inc. All rights reserved. Units: mm (inch) 21.5 (7/8) 435(17-1/8) 349.5(13-3/4) 391(15-3/8) 130(5-3/32) 151(5-15/16) 20 (13/16) 21 (27/32) WARNING Do not change the IMPEDANCE S
34、ELECTOR switch setting while the power to this unit is on, otherwise this unit may be damaged. IMPEDANCE SELECTOR 7 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS DISASSEMBLY PROCEDURES (Remove parts in disassembly order as numbered.) 1. Removal of Top Cover Remove 4 screws (1) and 4 screws (2) in Fig. 1.
35、2. Removal of Front Panel a. Remove 5 knobs. b. Remove 6 screws (3) in Fig. 1. Fig.1 1 23 4 567890ABC EFGHIJKLD 1 POWER TRANSFORMER 2 P.C.B. MAIN (3) 3 P.C.B. OPERATION (7) (R, T models only) 4 P.C.B. OPERATION (3) 5 P.C.B. MAIN (4) 6 P.C.B. MAIN (8) 7 P.C.B. OPERATION (6) 8 P.C.B. MAIN (2) 9 P.C.B.
36、 MAIN (1) 0 P.C.B. INPUT (2) A P.C.B. INPUT (1) B P.C.B. INPUT (3) C P.C.B. TUNER D P.C.B. MAIN (5) E P.C.B. OPERATION (5) F P.C.B. OPERATION (4) G P.C.B. MAIN (7) H P.C.B. OPERATION (1) I P.C.B. MAIN (6) J P.C.B. INPUT (4) K P.C.B. OPERATION (2) L P.C.B. DSP INTERNAL VIEW #14 #8 #7 #13 #9 Front Pan
37、el Top Cover Knob Knob 1 1 2 3 3 Knob 8 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS SELF DIAGNOSIS FUNCTION 1. PURPOSE AND OPERATION The RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS has a Self Diagnosis Function to locate a faulty part, if any, by inspecting and taking measurements. There are 11 main items i
38、n the diagnostic menu and some of them have sub-menu items as listed below. No. 1 2 3 4 5 6 7 8 9 10 11 SUB MENU 1. MAIN BYPASS 2. DSP 0dB 1. YSS908SRAM 2. YSS908 3. DSP FULL BIT 1. STATUS (BINARY FORM) 1. CENTER LARGE 2. EFFECT OFF 1. MAIN : SMALL 0dB 2. MAIN : LARGE 0dB 3. MAIN : LARGE 10dB 4. LFE
39、/BASS : MAIN CENTER : NONE 5. LFE/BASS : MAIN 6. LFE/BASS : SWFR 7. CENTER : NONE 8. CENTER : SMALL REAR : SMALL 9. FRONT MIX 1. EFFECT OFF 2. VFD DISP OFF 3. VFD DISP ALL 4. CHECKED PATTERN 5. RELEASE DATE 1. ALL 2. MAIN L 3. CENTER 4. MAIN R 5. REAR R 6. REAR L 7. LFE 1. INHIBIT(Inhibit Memory Ini
40、t) 2. RESERVED (Init. Memory) 1. 2. KEY 3. TUNING SIGNAL 5. PS PROTECTION 1. DSP CPU STATUS 2. CHANNEL STATUS 3. VERSION INFORMATION 4. CHECK SUM 5. BSI0 (AC3/DTS) 6. BSI1 7. BSI2 8. BSI3 9. BSI4 10. BSI5 1. MAIN MC CHECK SUM 2. SUB MC CHECK SUM 3. MAIN M.C. VERSION 4. SUB M.C. VERSION 5. PORT INFOR
41、MATION 6. EXIT MAIN MENU ANALOG THROUGH DSP THROUGH AC3/DTS THROUGH PRO LOGIC SPEAKERS SET EFFECT OFF /DISPLAY CHECK MANUAL TEST FACTORY PRESET AD DATA CHECK STATUS VERSION CHECK /DSP CPU SUM /EXIT REMOTE CONTROL CODE (KEY) 7A88 (1 DSP mode) 7A89 (2 DSP mode) 7A8A (3 DSP mode) 7A8B (4 DSP mode) 7A8C
42、 (5 DSP mode) 7A8D (6 DSP mode) 7A8E (7 DSP mode) 7A8F (8 DSP mode) 7A90 (9 DSP mode) 7A91 (0 DSP mode) 7A12 (ENTER DSP mode) 4. DC PROTECTION 9 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS MEMORY STANDBY/ON EDIT MODE TUNING MANL/AUTO FMAUTO/MANL MONO FM/AMTUNING DOWNUP INPUT MODE 1. 2. 3. 4. 5. 6. 7. EF
43、FECT LEVEL: MUTING: OFF INPUT (VIDEO): DVD/LD (DVD/LD) CENTER SPEAKER: LARGE REAR SPEAKER: LARGE MAIN SPEAKER: LARGE LFE/BASS OUT: SWFR CHANNELCENTERR SURL SURSWFR LEVEL (dB)0000 C. Start-up display The protection function information appears on the front panel display of the main unit. 2. BEGINNING
44、 AND CANCELLATION (1) STARTING UP THE FUNCTION AND THE DISPLAY After starting up, menu No. 1 is selected. A. How to start diagnostic program Using the front panel keys of the main unit. hold down the INPUT MODE and FM/AM keys simultaneously (Step 1), and press the STANDBY/ON key (Step 2); Plug in th
45、e AC power cord to the outlet, and when the main power off condition; submenu No. 1 of diagnosis main menu No. 1 will start. B. Settings for start-up of diagnostic program The settings used when starting the diagnostic program are as follows. FM/AM key FM/AM key INPUT MODE key FRONT PANEL Step1. Pre
46、ss the STANDBY/ON keyStep2. Hold down the INPUT MODE and FM/AM key simultaneously. 10 RX-V495/RX-V495RDS/HTR-5140/HTR-5140RDS History of protection function Each case of the history of the protection function is displayed as shown below. Appears when the protection function has not been activated. Appears when the current protection function has been activated. When power is turned on in an abnormal status, the power relay will come on, pro