Yamaha-RPU-200-Service-Manual电路原理图.pdf

上传人:cc518 文档编号:90888 上传时间:2020-10-11 格式:PDF 页数:52 大小:7.82MB
下载 相关 举报
Yamaha-RPU-200-Service-Manual电路原理图.pdf_第1页
第1页 / 共52页
Yamaha-RPU-200-Service-Manual电路原理图.pdf_第2页
第2页 / 共52页
Yamaha-RPU-200-Service-Manual电路原理图.pdf_第3页
第3页 / 共52页
亲,该文档总共52页,到这儿已超出免费预览范围,如果喜欢就下载吧!
资源描述

《Yamaha-RPU-200-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-RPU-200-Service-Manual电路原理图.pdf(52页珍藏版)》请在收音机爱好者资料库上搜索。

1、PERSONAL RECIEVER 100740 I CONTENTS TO SERVICE PERSONNEL . 1 FRONT PANEL . 2 REAR PANELS . 2 SPECIFICATIONS . 3 INTERNAL VIEW . 4 DISASSEMBLY PROCEDURES . 4 SELF DIAGNOSIS FUNCTION.5 13 FACTORY PRESET .14 15 STANDARD OPERATION CHART . 16 IC DATA .17 26 DISPLAY DATA . 27 PRINTED CIRCUIT BOARD .28 37

2、IC BLOCK .38 39 SCHEMATIC DIAGRAM .40 42 BLOCK DIAGRAM . 43 PARTS LIST .44 55 REMOTE CONTROL TRANSMITTER. 56 PARTS LIST FOR CARBON RESISTORS . 57 This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures in

3、herent to the industry, and more specifically YAMAHA Products, are already known and understood by the users, and have therefore not been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive

4、components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA product owners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any indi

5、vidual or firm does not constitute authorization, certification or recognition of any applicable technical capabilities, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineeri

6、ng, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Divis

7、ion. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. R

8、echeck all work before you apply power to the unit. IMPORTANT NOTICE RP-U200 SERVICE MANUAL RP-U200 RP-U200 RP-U200 I TO SERVICE PERSONNEL 1. Critical Components Information Components having special characteristics are marked Z and must be replaced with parts having specifications equal to those or

9、iginally installed. 2. Leakage Current Measurement (For 120V Models Only) When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. GMeter impedance should be equivalent to 1500 ohm shunted by 0.15F. GLeakage current

10、 must not exceed 0.5mA. AC LEAKAGE TESTER OR EQUIVALENT EQUIPMENT UNDER TEST INSULATING TABLE WALL OUTLET 1 WARNING: CHEMICAL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other electrical/ electronic and/or plastic (where applicable) components may al

11、so contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHATSOEVER! Avoid prolonged, u

12、nprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food. GBe sure to test for leakage with the

13、AC plug in both polarities. RP-U200 RP-U200 2 I FRONT PANEL POWER PC AUX1 AUX2 TUNER JAZZCHURCHHALL B VOLUMEMUTE CA MOVIELIVE PRESETMANUALMEMORY GAME TESTON/OFF /DTS SURROUND M U, C models I REAR PANELS M A model M B, G models RP-U200 RP-U200 3 I AUDIO SECTION Minimum RMS Output Power per Channel St

14、ereo, 20Hz to 20kHz, 1% THD, MAIN, 4 . . . . . . . 12W x 5 Maximum Power per Channel Stereo, 1kHz, EIAJ, 10% THD, MAIN, 4 . . . . . . . . . 14W x 5 Input Sensitivity/Impedance PC, AUX 1, AUX 2 (Analog) . . . . . . . . . . . . 150mV/35k Maximum Input Signal Level PC, AUX 1, AUX 2, 1kHz (DSP= THRU) .

15、. . . . . . . . 2.1V Output Level/Impedance REC OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . 150mV/2.0k SUB WOOFER (50Hz) . . . . . . . . . . . . . . . . . . . . . .1.0V/1.7k Headphone Jack Rated Output/Impedance PC Analog Input, etc (1kHz, 150mV) . . . . . . 320mV/61 Frequency Response

16、 USB 20Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -1.0 1.0dB 1kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0dB 20kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5 1.0dB PC, AUX Digital Input 20Hz . . . . . . . . . . . . . .

17、. . . . . . . . . . . . . . . . . -1.0 1.0dB 1kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0dB 20kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5 1.0dB Graphic Equalizer Frequency . . . . . . . . . . . .63/160/400/1k/2.5k/6.3k/16kHz Boost/cut .

18、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6dB Total Harmonic Distortion (1kHz, 20k LPF) USB to MAIN SP OUT (5V/4) . . . . . . . . . . . . . . . . . 0.2% PC, AUX Digital Input to MAIN SP OUT (5V/4) . . . 0.2% Signal-to-Noise Ratio (IHF-A-Network) USB to MAIN SP OUT (7V/4) . . .

19、. . . . . . . . . . . . . . 85dB PC, AUX Digital Input to MAIN SP OUT (7V/4) . . . 85dB Residual Noise (IHF-A-Network) MAIN L/R SP OUT . . . . . . . . . . . . . . . . . . . . . . . . . -66dBV I SPECIFICATIONS I GENERAL Power Supply U, C models . . . . . . . . . . . . . . . . . . . . . . . AC 120V, 6

20、0Hz A model . . . . . . . . . . . . . . . . . . . . . . . . . . . AC 240V, 50Hz B, G models . . . . . . . . . . . . . . . . . . . . . . . AC 230V, 50Hz Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90W Standby Power Consumption . . . . . . . . . . . . . . . . . . . . . 5W

21、 Dimensions (W x H x D) . . . . . . . . . . . . . 120 x 294 x 355mm (4-11/16” x 11-9/16” x 13-15/16”) Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 kg (12 lbs 2oz) Finish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Silver color Accessories . . . . . . . .

22、 . . . . Remote Control Transmitter x 1 Battery (size AA, R06) x 2 Indoor FM antenna x 1 USB Cable x 1 CD ROM x 1 * Specifications subject to change without notice. U . . . . . . . . . . USA model C . . . . . .Canadian model A . . . . . Australian model B . . . . . . . . British model G . . . . . Eu

23、ropean model G DIMENSIONS Units : mm (inch) 120 (411/16) 85 (35/16) 355 (1315/16) 253 (915/16) 13.5 (1/2) 13 (1/2) 294 (119/16) 281 (111/16) 283 (111/8) View Front View Front I FM SECTION Tuning Range U, C models . . . . . . . . . . . . . . . . . . . . . . .87.5 to 107.9MHz A, B, G models . . . . .

24、. . . . . . . . . . . . .87.50 to 108.00MHz Usable Sensitivity (30dB S/N Quietig) Mono (1kHz, 100% Mod.) . . . . . . . . . . . . . . . . . . . . . . 6dB Antenna Input . . . . . . . . . . . . . . . . . . . . . . . 75 unbalanced Manufactured under license from Dolby Laboratories. Dolby, AC-3, Pro Logi

25、c, and the double-D symbol V are trademarks of Dolby Laboratories. 1992-1997 Dolby Laboratories. All rights reserved. Manufactured under license from Digital Theater Systems, Inc. US Pat. No. 5,451,942 and other world-wide patents issued and pending. DTS, DTS Digital Surround, are trademarks of Digi

26、tal Theater Systems, Inc. copyright 1996 Digital Theater Systems, inc. All rights reserved. RP-U200 RP-U200 4 I INTERNAL VIEW I DISASSEMBLY PROCEDURES (Remove parts in the order as numbered.) 1. Removal of Top Cover Remove 14 screws ( q and w ) and then remove the Top Covers in Fig. 1. qDSP P.C.B. w

27、MAIN (2) P.C.B. eMAIN (1) P.C.B. rOPERATION (1) P.C.B. tOPERATION (2) P.C.B. qwert 2. Removal of Front Panel Remove 6 screws ( e ) and then remove the Front Panel in Fig. 2. 3. Checking the DSP P.C.B. Remove 4 screws ( r ) and then remove the Shield Case in Fig. 2. Fig. 2 Fig. 1 w q q q q q q e e r

28、Top Cover (R) r Front Panel Shield Case Top Cover (L) Top Cover The shield case can be removed only by loosening these 2 screws marked (r). RP-U200 RP-U200 5 I SELF DIAGNOSIS FUNCTION This product has a built-in self diagnosis function (DIAG) that can be used for inspection, measurement and determin

29、ation of a faulty point, if any. Listed below are these menu items and sub-menu items. Main menu ALL (Sequential test) DEV (Device test) DSP (DSP test) FL (FL test) AD (AD test) USB (USB loop back test) INIT (Memory initialization) VER (Version information) ERROR (Error history) Sub menu 1. THROUGH

30、2. DELAY 3. HALL 4. JAZZ 5. CHURCH 6. GAME 7. MOVIE 8. LIVE 9. PC-ANA 10. PC-Digi 11. AUX1-A 12. AUX1-D 13. AUX2-A 14. RETURN 1. AUTO 2. MANUAL 3. RETURN 1. KEY 2. LEVEL 3. JUDGE 4. V-ERR 5. V-MAX 6. V-MID60 7. V-MID55 8. V-MID52 9. V-MID49 10. V-MID29 11. V-MID1 12. V-MIN 13. RETURN 1.START 2. STOP

31、 3. RETURN 1. MEMORY 2. CANCEL 3. RETURN 1. SHV 2. EGAV 3. ChckSum 4. RETURN 1. E0- 2. E1- 3. E2- 4. E3- 5. E4- 6. E5 - 7. E6- 8. E7- 9. CLEAR 10. RETURN No. 1 2 3 4 5 6 7 8 9 Main menu DIT (Digital interface) U200 EXIT Sub menu 1. GENERAL 2. CD 3. PCM Enc 4. DAT 5. BS JPN 6. Synthe 7. AD 8. SD 9. B

32、S Eur 10. MIXER 11. SFC 12. DSP 13. L Pa:Ch 14. DIR RV 15. RETURN 1. All 5.1 2. Main 2ch 3. Rear 2ch 4. Center 1 5. Sub 1ch 6. Normal 6 7. Tmute ON 8. Tmut OFF 9. Smute ON 10. SmutOFF 11. LargeSP 12. SmallSP 13. T-Exit 14. RETURN No. 10 11 0 RP-U200 RP-U200 6 G Starting DIAG While the opening messag

33、e appearing at the power ON is on display, press the “DSP” key 3 times; quickly at the first and second times and keep pressing it at the third time until the DIAG function is started. G Display when DIAG function is started First, “DIAG” appears on the FL display of the main unit, followed by the v

34、ersion of the microcomputer for 1 second (e.g., 1.223f), the checksum of the microcomputer for 2 seconds (e.g., 83B3) and finally the DIAG menu (e.g., 1: ALL). Also, all the function LED segments light up. Version of the microcomputer Checksum of microcomputer D I A G 1 . 2 2 3 f 8 3 B 3 1 :A L L 1

35、second later 2 seconds later DIAG started (*1) If a protection function history has been recorded, the type of the protection function recorded last is displayed. When there is no protection history (*1) Some seconds later DIAG menu If the protection function activates after DIAG has been started an

36、d the power is turned off ; When the protection function (*2) activates, the protection function history appears on the display and the power turns off. Repair the faulty parts according to the displayed history. (*2) When any other faulty condition is found with the power source etc., the protectio

37、n function forces the power to turn off. PT PS display (When the power is turned on without this abnormality corrected, the protection function activates to shut off the power relay. Display may not light if there is an abnormality with the power supply for the display.) Cause: There is an abnormali

38、ty in the power supply section (voltage). Supplementary information: As the power from the following sources is detected, it is possible to determine where an abnormality exists. Stabilizing power source 15A, +9V, +5A, +5D SW, -VP +12V(Tuner), Vcc(for power IC) Besides the above possible causes, the

39、 cause may be disconnection of the connector or around the CPU. G Protection history When the protection function has activated, its history is stored in memory with a memory backup. Even when no abnormality is noted while the unit is being serviced, an abnormality which has occurred previously can

40、be defined as long as the backup data has been stored. The protection history should always be cleared before returning the unit from service. The protection history is cleared when DIAG is canceled by selecting “MEMORY” (memory initialization) from the setting items of the DIAG menu No.7 INT or whe

41、n the backup data is erased. RP-U200 RP-U200 7 G Canceling DIAG There are two methods to cancel the DIAG function. 1) Press the “POWER” (STANDBY) key of the main unit or the “POWER” (STANDBY) key of the remote controller to enter the stand-by state. 2) Selecting the DIAG menu item 0. EXIT, cancel th

42、e DIAG function. Then the self-diagnosis process ends and the normal operation is restored. CAUTION: Prior to cancellation of the DIAG function, be sure to execute setting of DIAG menu 7. INIT (reserve / reserve cancel of memory initialization). (To keep the user memory, execute “CANCEL” (cancellati

43、on of resetting reservation) of 7. INIT setting before canceling the DIAG function.) G Operation procedure of DIAG menu and SUB-MENU 1) Use the UP w (forward) / DOWN q (reverse) keys to select a main menu item. 2) For main menu items 1. ALL and 2. DEV neither of which has sub menu, the menu item is

44、executed when the DSP key is pressed. 3) For main menu items which have sub menu, the sub menu appears when the DSP key is pressed. 4) Use the UP w (forward) / DOWN q (reverse) keys to select a sub-menu item. 5) The sub-menu item is executed when the DSP key is pressed. 6) To return from the sub-men

45、u to the main menu, have “RETURN” displayed by using the UP w (forward) / DOWN q (reverse) keys and press the DSP key. 7) To return to the DIAG initial setting (1.ALL) during DIAG operation, press the MUTE key of remote control unit except for the special case (*3). (*3) : It is not possible to retu

46、rn to 1.ALL during execution of the AD test. Main unit UP w (forward) DOWN q (reverse) DSP MUTE Remote control key VOLUME UP w (forward) VOLUME DOWN q (reverse) ON/OFF Return the menu to the 1. ALL Remote control code 7B-0D 7B-0E 7B-07 7B-0F When using remote controller G Functions during DIAG opera

47、tion The following functions are available even during the DIAG operation. Power ON/OFF Master volume RP-U200 RP-U200 8 Details of DIAG menu Displaybit 7654 00000 10001 Display 0 0 0 0 0 00 0 0 0 bit7 6 5 43 2 1 0 Displaybit 3210 00000 10001 20010 30011 40100 50101 60110 70111 81000 91001 A1010 B1011 C1100 D1101 E1110 F1111 bit7Unused (“0

展开阅读全文
相关资源
猜你喜欢
相关搜索
资源标签

当前位置:首页 > 功放/音响/收扩 > Yamaha

copyright@ 2008-2023 收音机爱好者资料库 版权所有
备案编号:鄂ICP备16009402-5号