1、Design KI-1988 Rauland Ranger Media Management System: Design Guide Rauland-Borg Corporation Issued: 07/08/98 Page 1 of 15 RadioFans.CN 收音机爱 好者资料库 Copyright 1998 by Rauland-Borg Corporation, all rights reserved. This document contains users information on technology that is proprietary to Rauland-Bo
2、rg Corporation. Permitted transmittal, receipt, or possession of this document does not express license or imply any rights to use, sell, design or manufacture this information. No reproduction, publication, or disclosure of this information, in whole or in part, shall be made without prior written
3、authorization from an officer of Rauland-Borg Corporation. Rauland-Borg Corporation Rauland-Borg Corporation 3450 West Oakton Street Skokie, Illinois 60076-2958 (847) 679-0900 RadioFans.CN 收音机爱 好者资料库 KI-1988 Rauland Ranger Media Management Design GuideDesign Table of Contents GENERAL INFORMATION. 4
4、SCOPE OF THIS GUIDE. 4 Central Equipment. 6 Source Equipment.12 Rack Equipment.13 Classroom Equipment.13 KI-1988 Rauland Ranger Media Management Design GuideDesign Page 4 of 15 (Jul-98) General Information The Ranger Media Management System: Design Guide simplifies the ordering process by offering s
5、ummary information regarding Ranger Central, Source, Rack, and Classroom Equipment. Scope of this Guide First things first: do not use the original form to make or submit your order. Rather, make a photocopy and store the original in a safe place. Next, complete your copied form and either fax it fo
6、r review to a Sales Application Engineer or for order entry directly to the Customer Service Order Entry area. Should you prefer to use your Excel-equipped PC to complete the order form, an interactive, on-line version is available on the Rauland BBS (file name: “Quote.xls”). In either case, we sugg
7、est you keep a copy of your order on file for future reference. 1 KI-1988 Rauland Ranger Media Management Design GuideDesign Page 5 of 15 (Jul-98) Rauland Ranger Media Management System Please complete the following information before submitting your order: Distributor Information (Name, Address, Vo
8、ice and Fax Numbers): _ _ _ _ _ Customer Information (Customers Name, Address, Voice and Fax Numbers): _ _ _ _ _ Special Requirements/Other Information: _ _ _ _ KI-1988 Rauland Ranger Media Management Design GuideDesign Page 6 of 15 (Jul-98) Central Equipment Model No.Component Description Rack Spac
9、e Each Price EachQty. Total Rack Space Total Price RANPCSW Media Control Personal Computer (system) and Software. Provides media scheduling, database software, media source machine control and interface, interactive help, diagnostics, generates message screen displays, system setup and configuration
10、. One (1) PC required per Ranger system. A RANSHELF, RANMONMNT, and RANKEYMNT can be used to rack mount the RANPCSW. PC SYSTEM CONFIGURATION (ref.): Processor: 133 MHz Pentium Hard Disk: 850 MB Memory: 16 MB RAM Graphics: 14” Color SVGA, 2 MB VRAM CD-ROM: 12X (internal) Modem: 28.8K bps (internal) O
11、perating System: Microsoft Windows for Workgroups 3.11 See rack mount section RANCC16 Control Card Cage. Provides slots for sixteen (16) control cards each capable of controlling one (1) media device. One (1) required for every 16 media input devices. Power requirement: 12VDC, 120mA. 2 RU (3.5) RANC
12、PU Control CPU. One (1) required per Ranger system. Completely manages the entire media device control network. Handles up to 60,000pf of capacitance maximum on the control link cable. Mounts in the RANCC16. Power Requirement: 12VDC, 100mA. For systems larger than 255 devices or 120 classrooms conta
13、ct Rauland-Borg for system design and pricing. Mounts in the RANCC16 RANBROAD Control Expander. Required if the amount of control cable cannot be accommodated by the RANCPU (exceeds 60,000pf). Handles 10 runs of cable; each with a maximum of 60,000pf. Power Requirement: 12VDC, 200mA 1 RU (1.75) KI-1
14、988 Rauland Ranger Media Management Design GuideDesign Model No.Component Description Rack Space Each Price EachQty. Total Rack Space Total Price Page 7 of 15 (Jul-98) RANIR Infrared Control Card. Provides control for a wide variety of IR media devices. Includes IR transmitter cable (RANIRCABLE) One
15、 (1) required for each IR media device (e.g. Still Video player, VCR, CD-I Player). Mounts in the RANCC16 Control Card Cage. Power Requirement: 12VDC, 45mA Mounts in RANCC16 RAN232 Data Control Card. Provides control for a wide variety of media and computer devices. One (1) required to support the R
16、ANPCSW . One (1) required to support the Video Matrix Switch (RANxVSy). One (1) required for each RS232/422 Controlled Media Device (e.g. Laser Disc Player, Character Generators, etc.). Mounts in the RANCC16 Control Card Cage. Power Requirement: 12VDC, 125mA. Mounts in RANCC16 RANRLY8 Relay Control
17、Card. Provides 8 relays for specialized control functions. Power Requirement: 12VDC, 125ma. Mounts in RANCC16 RANCAGE Fiber and Multiplexer Card Cage. Required for mounting the audio/video multiplexers (RANAVMS2) as well as the fiber cards (RANFT4, RANFR4). This card cage holds either ten (10) RANFT
18、4 Fiber Transmitter Cards, ten (10) RANFR4 Fiber Receiver Cards, or ten (10) RANAVMS2 Multiplexer Cards. Mounts in the Central Equipment Rack. 4 RU (7) RANAVMS2 Audio/Video Multiplexer. One (1) required for every two (2) inputs in a baseband system (e.g. media devices, demodulated broadcast channels
19、 , satellite inputs). Use only with systems using the RANCL101CP in the classroom. Mounts in RANCAGE RANFT4 Quad Fiber Transmitter Card. One (1) required for every four (4) outputs (Classrooms) in a fiber-based system. Not required for a baseband coax system. Power Requirement: 12VDC, 200mA. Mounts
20、in RANCAGE RANFT4FM Quad FM Fiber Transmitter Card. FM version of RANFT4 Mounts in RANCAGE RANFR4 Quad Fiber Receiver Card. One (1) required for every four (4) classrooms returning local origination for Mounts in KI-1988 Rauland Ranger Media Management Design GuideDesign Model No.Component Descripti
21、on Rack Space Each Price EachQty. Total Rack Space Total Price Page 8 of 15 (Jul-98) distribution in a fiber-based baseband system. Not required for a baseband coax system. Power Requirement: 12VDC, 400mA RANCAGE RANFR4FM Quad FM Fiber Receiver. FM Version of RANFR4. Mounts in RANCAGE RANPS12 Power
22、Supply. Provides 12.5 amps at 12VDC. One (1) or more required to power the central equipment Mounts in the central equipment rack. Mounts on side or bottom of rack RANMON13 13 Monitor. One (1) required in the central equipment. Maximum of four (4) per system. Allows the Learning Resource Center to v
23、iew classroom programs. Uses the RANMONMNT Rack Mount Kit. 8 RU (14) KI-1988 Rauland Ranger Media Management Design GuideDesign Model No.Component Description Rack Space Each Price EachQty. Total Rack Space Total Price Page 9 of 15 (Jul-98) RANxVSy Video Matrix Switch. Video Matrix switches are avai
24、lable in any size increment of ten (10) inputs and ten (10) outputs The video matrix switch size should be carefully planned in order to allow for future expansion. ?For a baseband Ranger System, the outputs are simply the number of locations (classrooms and rack-mounted operators monitors) that wil
25、l be viewing the centrally located media (in multiples of 10). ?For a broadband Ranger System, the outputs are the number of modulated channels reserved for Ranger viewing (in multiples of 10). Each of the following should be considered inputs for the video switch: 1. Media Devices (VCRs, Laser Disc
26、 Players, etc.) 2. Demodulated Broadcast/Cable Channels (each channel to be distributed through a baseband Ranger system) 3. Satellite or Microwave Transmissions 4. Local Origination Inputs (video all call) One (1) RAN232 Data Control Card is required for the Video Matrix Switch. The video matrix sw
27、itch should be ordered under the part number of RANxVSy x = number of inputs y = number of outputs. For example, if a 20 input by 60 output switch is required, a RAN20VS60 should be ordered. KI-1988 Rauland Ranger Media Management Design GuideDesign Model No.Component Description Rack Space Each Pri
28、ce EachQty. Total Rack Space Total Price Page 10 of 15 (Jul-98) RANxVSy (Continued) Each video switch consists of the following components: 1. RAN10C10 Crosspoint Cards. Quantity needed is (x(inputs rounded up to the nearest 10) times y(outputs rounded up to the nearest 10)divided by 100. Ex: Given
29、13 actual Inputs and 61 actual Outputs. Calculation: 13 rounds up to 20, 61 rounds up to 70. Crosspoint Cards = (20 X 70) / 100 = 14 2.RANVIDOUT Output Cards. Quantity needed is youtputs (rounded up to the nearest 10) divided by 10. 3.RAN50VS20 Entrance Frame. One (1) required if total number of inp
30、uts x is 50 or less. Provides mounting for 2 output cards. 4.RAN70VS20 Entrance Frame. One (1) required if the total number of inputs x is 70 or less. Provides mounting for 2 output cards. 5.RAN110VS10 Entrance Frame. One (1) required if the total number of inputs x is 110 or less. Provides mounting
31、 for 1 output card. RAN150VS10 Entrance Frame. One (1) required if the total number of inputs x is 150 or less. Provides mounting for 1 output card. RAN50X20 Expansion Frame. One (1) required for every 20 outputs excluding the 20 provided with the entrance frame. RAN70X20 Expansion Frame. One (1) re
32、quired for every 20 outputs excluding the 20 provided with the entrance frame. 6. RAN110X10 Expansion Frame. One (1) required for every 10 outputs, excluding the 10 included with the entrance frame. 7. RAN150X10 Expansion Frame. One (1) required for every 10 outputs, excluding the 10 included with t
33、he entrance frame. RAN10C10 mounts in frames. RANVIDOUT mounts in frames RAN50VS20 RAN70VS20 RAN110VS10 RAN50X20 RAN70X20 RAN110X10 6RU (10.5) KI-1988 Rauland Ranger Media Management Design GuideDesign Model No.Component Description Rack Space Each Price EachQty. Total Rack Space Total Price Page 11
34、 of 15 (Jul-98) VW2294 Control Cable. with Connectors. Connects RANCC16 to Character Generators Not Applicable VW2292 Control Cable. Connects RANCC16 to laser disc players Not Applicable RANSYNCR Sync Pulse Generator. One (1) required per baseband system for the character generator Mounts on the sid
35、e or rack RANLPSW Lesson Plan Software. (optional) Allows the user to create a multi-media presentation and store the commands for later scheduling and use. Runs on both Windows and Macintosh machines. Standard software allows 10 simultaneous users on a Microsoft Windows NT, Novell Netware, or Apple
36、Share network (must be Ethernet or Token Ring). See specification sheet for additional requirements. Not Applicable RANREMOTSW Remote Scheduling Software (optional). Allows users to schedule media titles and resources from network workstations. Runs on both Windows and Macintosh machines. Standard s
37、oftware allows 10 simultaneous users on a Microsoft Windows NT, Novell NetWare, or AppleShare network. See specification sheet for additional requirements. Not Applicable Central Equipment Total (add cost of all “central equipment” together) _ KI-1988 Rauland Ranger Media Management Design GuideDesi
38、gn Page 12 of 15 (Jul-98) Source Equipment Model No.Component Description Rack Space Each Price EachQty. Total Rack Space Total Price RAN16MM 16mm to Video Converter. One (1) RANIR is required for each RAN16MM Table Mount RAN35MM 35mm to Video Converter. One (1) RANIR is required for each RAN35MM. T
39、able Mount RANCDROM CD-ROM Drive. One (1) RANIR is required for each CD-ROM drive. Each CD-ROM drive requires a computer as well as a RANNTSC for NTSC video output (see specification sheet for details). Requires a RANSHELF Rack Mount Kit. 3 RU (5.25) RANCDI CD-Interactive Player. One (1) RANIR IR Co
40、ntrol Card is required for each CD-I player. Requires a RANSHELF Rack Mount Kit. 3 RU (5.25) RANMENU Character Generator Kit. Allows system to display available media devices (with courseware titles) on the classroom monitor. Multiple RANMENUs can be used in a Ranger system to minimize blocking (rec
41、ommend one for every 30 classrooms). Kit includes software, cable and a VGA/NTSC converter. You must supply an IBM compatible PC with VGA output and Microsoft MS- DOS (no monitor, keyboard or hard drive is required). One (1) RAN232 Data Control Card required for each character generator in the syste
42、m. Requires a RANSHELF. VS2293-1 cable (included). 3 RU (5.25) RANVCR Video Cassette Player. One (1) RANIR Control Card is required for each VCR Requires a RANSHELF for rack mounting. 3 RU (5.25) RANSVHS Super VHS Video Cassette Player. One (1) RANIR IR Control Card is required for each SVHS player.
43、 Requires a RANSHELF rack mount kit. 3 RU (5.25) RANVEDIT VHS/SVHS Editing System. One (1) RANIR is required for each RANVEDIT. Requires a RANSHELF for rack mounting. 3 RU (5.25) Source Equipment Total (add cost of all “source equipment” together) _ KI-1988 Rauland Ranger Media Management Design GuideDesign Page 13 of 15 (Jul-98) Rack Equipment Model No.Component Description Rack Space Each Price EachQty. Total Rack Space Total Price RANRACK61 61 Black Rack, 24 deep, rear door, removable sides. Add suffix “P” for pontoon base wit